Dissertation · 2004 · Open access

Developing a tool for evaluating the eficiency of a water-cooling tower.

Blanca Johana Calderon Godoy, Helmer Geobel Pinto Galvis

Universidad Industrial de Santander · Published 1 January 2004

Open PDFView at the publisherCite this paper

In brief

“Developing a tool for evaluating the eficiency of a water-cooling tower.” is a 2004 dissertation by Blanca Johana Calderon Godoy and Helmer Geobel Pinto Galvis, published in Universidad Industrial de Santander. OpenAlex counts 0 citations as of 22 November 2026. It is open access under a CC BY licence: the full text is free to read at Universidad Industrial de Santander.

Citations
0
Authors
2

Abstract

La herramienta propuesta permite el cálculo del perfil de temperatura para el agua, el perfil de temperatura para el aire, el perfil de humedad y la demanda térmica a contracorriente en una torre de enfriamiento de agua de tiro inducido a contracorriente. Como un primer paso, se construye un modelo matemático, que rige el funcionamiento de una torre de enfriamiento de agua de tiro inducido a contracorriente que contiene un empaque de madera vertical. El modelo matemático estructurado contiene ecuaciones que describen los fenómenos de transferencia de masa, transferencia de calor , el balance de energía y la ecuación de equilibrio generada a partir de datos para el sistema aire-agua reportados en la literatura. En el modelo también se incluyen ecuaciones que modelan el comportamiento termodinámico de la torre partiendo de datos de entalpía de la mezcla aire-vapor de agua a 1 atmósfera de presión. Una vez conformado el modelo, este se resuelve numéricamente para cada uno de los empaques utilizados partiendo de las mismas condiciones de operación y diseño con el fin de obtener los resultados del modelo operacional, luego se obtiene la demanda térmica a contracorriente a partir de las condiciones de diseño. Por último, se generan diferentes datos de condiciones de operación con el fin de evaluar la demanda térmica a contracorriente para la herramienta y para el demo CTI Toolkit de Cooling Tower Institute. De la solución numérica se obtuvo el calor removido por la torre, el porcentaje de agua perdido, la temperatura de agua fría, la temperatura del aire a la salida, la demanda térmica a contracorriente, los perfiles de temperatura para el agua y el aire y el perfil de humedad. Además, se obtiene que el empaque más eficiente es el de madera vertical y que la herramienta tiene una confiabilidad del 98% al compararla con el demo CTI Toolkit de Cooling Tower Institute.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Godoy, B. J. C., & Galvis, H. G. P. (2004). Developing a tool for evaluating the eficiency of a water-cooling tower. Universidad Industrial de Santander. https://noesis.uis.edu.co/handle/20.500.14071/16099

MLA 9

Godoy, Blanca Johana Calderon, and Helmer Geobel Pinto Galvis. “Developing a tool for evaluating the eficiency of a water-cooling tower.” Universidad Industrial de Santander, 2004. https://noesis.uis.edu.co/handle/20.500.14071/16099.

Chicago

Godoy, Blanca Johana Calderon and Helmer Geobel Pinto Galvis. 2004. “Developing a tool for evaluating the eficiency of a water-cooling tower.” Universidad Industrial de Santander. https://noesis.uis.edu.co/handle/20.500.14071/16099.

Harvard

Godoy, B. J. C. and Galvis, H. G. P. (2004) ‘Developing a tool for evaluating the eficiency of a water-cooling tower.’, Universidad Industrial de Santander. Available at: https://noesis.uis.edu.co/handle/20.500.14071/16099.

IEEE

B. J. C. Godoy and H. G. P. Galvis, “Developing a tool for evaluating the eficiency of a water-cooling tower.,” Universidad Industrial de Santander, 2004.

BibTeX

@phdthesis{godoy2004developing,
  title     = {{Developing a tool for evaluating the eficiency of a water-cooling tower.}},
  author    = {Godoy, Blanca Johana Calderon and Galvis, Helmer Geobel Pinto},
  year      = {2004},
  url       = {https://noesis.uis.edu.co/handle/20.500.14071/16099}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization

  • counterflow cooling tower
  • humidity profiles
  • heat and mass transfer
  • water loss

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Godoy, B. J. C., & Galvis, H. G. P. (2004). Developing a tool for evaluating the eficiency of a water-cooling tower. Universidad Industrial de Santander. https://noesis.uis.edu.co/handle/20.500.14071/16099

How many times has this paper been cited?

0 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Universidad Industrial de Santander: sign in and open the PDF from this page.

Who wrote this paper?

Blanca Johana Calderon Godoy, Helmer Geobel Pinto Galvis.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.