Dissertation · 2011 · Open access

Operational design for a counter-current adiabatic induced mechanical draft water cooling tower in laboratory scale2.

Jonatan Ricardo Restrepo García

Universidad Industrial de Santander · Published 1 January 2011

Open PDFView at the publisherCite this paper

In brief

“Operational design for a counter-current adiabatic induced mechanical draft water cooling tower in laboratory scale2.” is a 2011 dissertation by Jonatan Ricardo Restrepo García, published in Universidad Industrial de Santander. OpenAlex counts 1 citations as of 22 November 2026. It is open access under a CC BY licence: the full text is free to read at Universidad Industrial de Santander.

Citations
1
Most cited in
2014 (1)
References
7
Authors
1

Abstract

Las torres de enfriamiento se han vendido desarrollando paulatinamente con el desarrollo y adecuación de nuevas tecnologías, los dispositivos de enfriamiento evaporativo han sido por décadas estudiados, implementados y dispuestos bajo las consideraciones y restricciones operativas adecuadas dentro de un sistema determinado de control. Existen gran variedad de configuraciones para los procesos de enfriamiento del agua, dependiendo de la manera en la cual se diseña y ajusta las necesidades energéticas y de flujo. El tiro inducido es la configuración más apropiada en el estudio y aplicación para las torres de enfriamiento de tamaño pequeño debido a que favorece una distribución uniforme del aire, aumentando en consecuencia la eficiencia del dispositivo. El presente trabajo desarrolla el diseño operacional para una torre de enfriamiento de tiro inducido a fin de ser implementada y adecuada dentro del laboratorio de procesos y operaciones unitarias de la Escuela de Ingeniería Química de la Universidad Industrial de Santander. Las ecuaciones de diseño del equipo en general se basan en la teoría del Potencial Entálpico descrita y desarrollada por Merkel, conforme a las normas establecidas por el Cooling Tower Institute. El diseño desarrollado envuelve además los equipos accesorios tales como Intercambiador de calor, tipo tubos y carcasa, ventilador axial, bomba centrifuga, accesorios y tuberías con su respectiva instrumentación y equipos para la medición y control, El tipo de relleno de arreglo tipo hexagonal de PVC validado por las correlaciones para la transferencia de masa y energía comúnmente reportadas.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

García, J. R. R. (2011). Operational design for a counter-current adiabatic induced mechanical draft water cooling tower in laboratory scale2. Universidad Industrial de Santander. https://noesis.uis.edu.co/handle/20.500.14071/25756

MLA 9

García, Jonatan Ricardo Restrepo. “Operational design for a counter-current adiabatic induced mechanical draft water cooling tower in laboratory scale2.” Universidad Industrial de Santander, 2011. https://noesis.uis.edu.co/handle/20.500.14071/25756.

Chicago

García, Jonatan Ricardo Restrepo. 2011. “Operational design for a counter-current adiabatic induced mechanical draft water cooling tower in laboratory scale2.” Universidad Industrial de Santander. https://noesis.uis.edu.co/handle/20.500.14071/25756.

Harvard

García, J. R. R. (2011) ‘Operational design for a counter-current adiabatic induced mechanical draft water cooling tower in laboratory scale2.’, Universidad Industrial de Santander. Available at: https://noesis.uis.edu.co/handle/20.500.14071/25756.

IEEE

J. R. R. García, “Operational design for a counter-current adiabatic induced mechanical draft water cooling tower in laboratory scale2.,” Universidad Industrial de Santander, 2011.

BibTeX

@phdthesis{garcia2011operational,
  title     = {{Operational design for a counter-current adiabatic induced mechanical draft water cooling tower in laboratory scale2.}},
  author    = {García, Jonatan Ricardo Restrepo},
  year      = {2011},
  url       = {https://noesis.uis.edu.co/handle/20.500.14071/25756}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization

  • induced draft cooling tower
  • operational design
  • heat and mass transfer
  • axial fan
  • centrifugal pump
  • water cooling

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

García, J. R. R. (2011). Operational design for a counter-current adiabatic induced mechanical draft water cooling tower in laboratory scale2. Universidad Industrial de Santander. https://noesis.uis.edu.co/handle/20.500.14071/25756

How many times has this paper been cited?

1 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Universidad Industrial de Santander: sign in and open the PDF from this page.

Who wrote this paper?

Jonatan Ricardo Restrepo García.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.