Dissertation · 2011 · Open access
Modelagem fenomenológica do desempenho de torres de resfriamento de água acopladas e estudo de casos.
Digital Library of Theses and Dissertations (Universidade de São Paulo) · Published 3 June 2011 · DOI 10.11606/d.3.2011.tde-26082011-141855
In brief
“Modelagem fenomenológica do desempenho de torres de resfriamento de água acopladas e estudo de casos.” is a 2011 dissertation by Rafael Candido de Lima, published in Digital Library of Theses and Dissertations (Universidade de São Paulo). OpenAlex counts 1 citations as of 22 November 2026. It is open access: the full text is free to read at Digital Library of Theses and Dissertations (Universidade de São Paulo).
- Citations
- 1
- Most cited in
- 2015 (1)
- References
- 16
- Authors
- 1
Abstract
This is a study about the phenomenological modeling of the performance of a water cooling tower and a system of two cooling towers in series, with water temperature input up to 65°C.The validity of model was verified by comparing the expected results with those obtained in tests on a pilot plant.After this, through a mathematical simulation, based on the model developed, several cases of application were analyzed.It was studied the influence of main operating variables (air flow, water flow and wet bulb temperature) on the performance of couples cooling towers (in series and parallel) and on operational cost.It was verified the most influential variable is the water flow rate through the tower.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
de Lima, R. C. (2011). Modelagem fenomenológica do desempenho de torres de resfriamento de água acopladas e estudo de casos. Digital Library of Theses and Dissertations (Universidade de São Paulo). https://doi.org/10.11606/d.3.2011.tde-26082011-141855
MLA 9
de Lima, Rafael Candido. “Modelagem fenomenológica do desempenho de torres de resfriamento de água acopladas e estudo de casos.” Digital Library of Theses and Dissertations (Universidade de São Paulo), 2011. https://doi.org/10.11606/d.3.2011.tde-26082011-141855.
Chicago
de Lima, Rafael Candido. 2011. “Modelagem fenomenológica do desempenho de torres de resfriamento de água acopladas e estudo de casos.” Digital Library of Theses and Dissertations (Universidade de São Paulo). https://doi.org/10.11606/d.3.2011.tde-26082011-141855.
Harvard
de Lima, R. C. (2011) ‘Modelagem fenomenológica do desempenho de torres de resfriamento de água acopladas e estudo de casos.’, Digital Library of Theses and Dissertations (Universidade de São Paulo). doi:10.11606/d.3.2011.tde-26082011-141855.
IEEE
R. C. de Lima, “Modelagem fenomenológica do desempenho de torres de resfriamento de água acopladas e estudo de casos.,” Digital Library of Theses and Dissertations (Universidade de São Paulo), 2011, doi: 10.11606/d.3.2011.tde-26082011-141855.
BibTeX
@phdthesis{delima2011modelagem,
title = {{Modelagem fenomenológica do desempenho de torres de resfriamento de água acopladas e estudo de casos.}},
author = {de Lima, Rafael Candido},
year = {2011},
doi = {10.11606/d.3.2011.tde-26082011-141855},
url = {https://doi.org/10.11606/d.3.2011.tde-26082011-141855}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- water cooling towers
- phenomenological model
- cooling tower performance
- air flow rate
- water flow rate
- wet-bulb temperature
- operating costs
- pilot plant testing
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
de Lima, R. C. (2011). Modelagem fenomenológica do desempenho de torres de resfriamento de água acopladas e estudo de casos. Digital Library of Theses and Dissertations (Universidade de São Paulo). https://doi.org/10.11606/d.3.2011.tde-26082011-141855
How many times has this paper been cited?
1 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Digital Library of Theses and Dissertations (Universidade de São Paulo): sign in and open the PDF from this page.
Who wrote this paper?
Rafael Candido de Lima.
What is the DOI of this paper?
10.11606/d.3.2011.tde-26082011-141855, permanently at https://doi.org/10.11606/d.3.2011.tde-26082011-141855. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.