Some Hints to Avoid Pitfalls in Quantitative Determination of Glutathione Peroxidase (EC 1.11.1.9)
Clinical Chemistry and Laboratory Medicine (CCLM), 8(2), 156–161 · Published 1 March 1970 · DOI 10.1515/cclm.1970.8.2.156
In brief
“Some Hints to Avoid Pitfalls in Quantitative Determination of Glutathione Peroxidase (EC 1.11.1.9)” is a 1970 journal article by Leopold Flohé and Ingeborg A. Brand, published in Clinical Chemistry and Laboratory Medicine (CCLM). OpenAlex counts 25 citations as of 20 November 2026. It is open access: the full text is free to read at Clinical Chemistry and Laboratory Medicine (CCLM).
- Citations
- 25
- Most cited in
- 2018 (2)
- Field-weighted impact
- 2.39
- Authors
- 2
Abstract
Methods of quantitative determination of glutathione peroxidase were reinvestigated with respect to reliability and specificity.The determination of product (GSSG) by a coupled enzymatic oxidation of NADPH, as described by PAGLIA and VALENTINE, had to be modified as follows: 1.The concentration of GSH was lowered to a maximum of 1 mM in the incubation mixture to avoid product inhibition of GSSG reductase.2. The concentration of H 2 O 2 was increased to guarantee a sufficient amount of substrate to survive the lag phase of the coupled enzymatic test.The pretreatment of the samples proposed by PAGLIA and VALENTINE (13) was föund'to be insufficient for obtaining exact data on GSH peroxidase activity as all hemoglobin derivatives tested, including cyanmethemoglobin, caused a significant unspecific oxidation of GSH by H 2 O 2 .The determination of GSH peroxidase activity described by SCHNEIDER and FLOHE (3) as well as their procedure to purify the enzyme prior to measurement was found to be reliable and adequately reproducible.In view of the lower apparative requirements, however, the procedure of PAGLIA and VALENTINE offers a more suitable clinical screening test if the possible errors mentioned below are considered.The influence of the medium on GSH peroxidase activity was investigated.The definitions of the enzyme unit are discussed with respect to the kinetic behaviour of GSH peroxidase.Our unit of activity is defined as the amount of enzyme dissolved in 1 m/ which effects a difference of 1 in the logarithms of the GSH concentrations per minute.Methoden zur quantitativen Bestimmung von Glutathionperoxydase wurden in Hinsicht auf Verläßlichkeit und Spezifität geprüft.Die Bestimmung des Produktes (GSSG) mit Hilfe des gekoppelten enzymatischen Testes nach PAGLIA und VALENTINE mußte wie folgt modifiziert werden: 1. Die GSH-Konzentration wurde auf maximal l mM im Inkubationsansatz gesenkt, um die Produkthemmurig der Glutathionreduktase zu umgehen.2. Die Konzentration von H 2 O 2 wurde erhöht, um sicherzustellen, daß nach Verstreichen der dem Test eigentümlichen Lagphase noch ein ausreichendes Substratangebot gegeben ist.Die von PAGLIA und VALENTINE vorgeschlagene Vorbehandlung der Proben erwies sich als unzureichend, wenn die Aktivität der Glutathionperoxydase exakt ermittelt werden soll, da sämtliche untersuchten Hämoglobinderivate einschließlich Cyanmethämoglobin eine signifikante unspezifische Glutathionoxydation durch H 2 O 2 bewirken.Die von SCHNEIDER und FLOHE beschriebene Bestimmung der GSH-Peroxydase-Aktivität wie auch deren Vorschrift zur Abtrennung des Enzyms vor der Bestimmung erwies sich als zuverlässig und ausreichend reproduzierbar.Wegen des geringen apparativen Aufwands jedoch scheint die Methode von PAGLIA und VALENTINE unter Beachtung der genannten Fehlermöglichkeiten als klinischer Screening-Test geeigneter.Ferner wurde der Einfluß des Inkubationsmediums auf die Glutathionperoxydaseaktivität untersucht.Die Definitionen der Enzymeinheit werden diskutiert in Hinblick auf die…
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Flohé, L., & Brand, I. A. (1970). Some Hints to Avoid Pitfalls in Quantitative Determination of Glutathione Peroxidase (EC 1.11.1.9). Clinical Chemistry and Laboratory Medicine (CCLM), 8(2), 156–161. https://doi.org/10.1515/cclm.1970.8.2.156
MLA 9
Flohé, Leopold, and Ingeborg A. Brand. “Some Hints to Avoid Pitfalls in Quantitative Determination of Glutathione Peroxidase (EC 1.11.1.9).” Clinical Chemistry and Laboratory Medicine (CCLM), vol. 8, no. 2, 1970, pp. 156–161. https://doi.org/10.1515/cclm.1970.8.2.156.
Chicago
Flohé, Leopold and Ingeborg A. Brand. 1970. “Some Hints to Avoid Pitfalls in Quantitative Determination of Glutathione Peroxidase (EC 1.11.1.9).” Clinical Chemistry and Laboratory Medicine (CCLM) 8 (2): 156–161. https://doi.org/10.1515/cclm.1970.8.2.156.
Harvard
Flohé, L. and Brand, I. A. (1970) ‘Some Hints to Avoid Pitfalls in Quantitative Determination of Glutathione Peroxidase (EC 1.11.1.9)’, Clinical Chemistry and Laboratory Medicine (CCLM), 8(2), pp. 156–161. doi:10.1515/cclm.1970.8.2.156.
IEEE
L. Flohé and I. A. Brand, “Some Hints to Avoid Pitfalls in Quantitative Determination of Glutathione Peroxidase (EC 1.11.1.9),” Clinical Chemistry and Laboratory Medicine (CCLM), vol. 8, no. 2, pp. 156–161, 1970, doi: 10.1515/cclm.1970.8.2.156.
BibTeX
@article{flohe1970some,
title = {{Some Hints to Avoid Pitfalls in Quantitative Determination of Glutathione Peroxidase (EC 1.11.1.9)}},
author = {Flohé, Leopold and Brand, Ingeborg A.},
journal = {Clinical Chemistry and Laboratory Medicine (CCLM)},
year = {1970},
volume = {8},
number = {2},
pages = {156--161},
doi = {10.1515/cclm.1970.8.2.156},
url = {https://doi.org/10.1515/cclm.1970.8.2.156}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2018 | 2 | |
| 2020 | 1 | |
| 2023 | 1 |
Its field-weighted citation impact is 2.39: it has been cited 2.39 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Health Sciences › Nursing › Nutrition and Dietetics › Selenium in Biological Systems
- glutathione peroxidase
- glutathione disulfide
- glutathione reductase inhibition
- hydrogen peroxide
- sample preparation
- hemoglobin derivatives
- enzyme kinetics
- enzyme purification
Work with this paper
Most-cited papers in Nursing
- Magnesium Replacement Improves the Metabolic Profile in Obese and Pre-Diabetic Patients with Mild-to-Moderate Chronic Kidney Disease: A 3-Month, Randomised, Double-Blind, Placebo-Controlled StudyÖmer Toprak, Hüseyin Kurt, Yasin Sarı and 3 more · Kidney & Blood Pressure Research · 2017 · 29,772 citations
- The “Golden Age” of Probiotics: A Systematic Review and Meta-Analysis of Randomized and Observational Studies in Preterm InfantsElda Dermyshi, Yizhong Wang, Chongbing Yan and 4 more · Neonatology · 2017 · 24,587 citations
- Studies on the quantitative and qualitative characterization of erythrocyte glutathione peroxidase.Donald E. Paglia, William N. Valentine · PubMed · 1967 · 10,901 citations
- Maternal and child undernutrition and overweight in low-income and middle-income countriesRobert E. Black, Cesar Gomes Victora, Susan P. Walker and 8 more · The Lancet · 2013 · 9,505 citations
- The content validity index: Are you sure you know what's being reported? critique and recommendationsDenise F. Polit, Cheryl Tatano Beck · Research in Nursing & Health · 2006 · 8,193 citations
Questions about this paper
How do I cite this paper in APA style?
Flohé, L., & Brand, I. A. (1970). Some Hints to Avoid Pitfalls in Quantitative Determination of Glutathione Peroxidase (EC 1.11.1.9). Clinical Chemistry and Laboratory Medicine (CCLM), 8(2), 156–161. https://doi.org/10.1515/cclm.1970.8.2.156
How many times has this paper been cited?
25 times, according to OpenAlex on 20 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Clinical Chemistry and Laboratory Medicine (CCLM): sign in and open the PDF from this page.
Who wrote this paper?
Leopold Flohé, Ingeborg A. Brand.
What is the DOI of this paper?
10.1515/cclm.1970.8.2.156, permanently at https://doi.org/10.1515/cclm.1970.8.2.156. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 20 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.