Journal article · 1974 · Open access

An Improved Coupled Test Procedure for Glutathione Peroxidase (EC 1.11.1.9.) in Blood

Wolfgang A. Günzler, H. Kremers, Leopold Flohé

Clinical Chemistry and Laboratory Medicine (CCLM), 12(10), 444–448 · Published 1 October 1974 · DOI 10.1515/cclm.1974.12.10.444

Open PDFView at the publisherCite this paper

In brief

“An Improved Coupled Test Procedure for Glutathione Peroxidase (EC 1.11.1.9.) in Blood” is a 1974 journal article by Wolfgang A. Günzler and 2 co-authors, published in Clinical Chemistry and Laboratory Medicine (CCLM). OpenAlex counts 511 citations as of 20 November 2026, which puts it in the top 5% of works published in 1974 by citations. It is open access: the full text is free to read at edoc Publication server (Humboldt University of Berlin).

Citations
511
Most cited in
2017 (13)
Field-weighted impact
1.73
References
22
Authors
3

Abstract

An optimized coupled test system for glutathione peroxidase in red blood cells is presented. In the improved assay, tert. butyl hydro-peroxide was employed as an acceptor substrate at twenty times Km(app) concentration. By aid of a batching procedure for instant separation of hemoglobin from glutathione peroxidase, it could be proved that cyanmethemoglobin in the modified procedure does not affect the spontaneous reaction rate. Further possible interference with the determination could be excluded. Glutathione peroxidase activities in red blood cells of normal adults were measured by the improved test method. A glutathione peroxidase activity in human plasma was observed. Die gekoppelte Testmethode zur Bestimmung von Glutathionperoxidase in Erythrocyten wurde optimiert, im verbesserten Ansatz wurde tert. Butylhy droperoxid als Akzeptorsubstrat in zwanzigfacher Km(app)-Konzentration eingesetzt. Hämogjobin, das durch

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Günzler, W. A., Kremers, H., & Flohé, L. (1974). An Improved Coupled Test Procedure for Glutathione Peroxidase (EC 1.11.1.9.) in Blood. Clinical Chemistry and Laboratory Medicine (CCLM), 12(10), 444–448. https://doi.org/10.1515/cclm.1974.12.10.444

MLA 9

Günzler, Wolfgang A., et al. “An Improved Coupled Test Procedure for Glutathione Peroxidase (EC 1.11.1.9.) in Blood.” Clinical Chemistry and Laboratory Medicine (CCLM), vol. 12, no. 10, 1974, pp. 444–448. https://doi.org/10.1515/cclm.1974.12.10.444.

Chicago

Günzler, Wolfgang A., H. Kremers, and Leopold Flohé. 1974. “An Improved Coupled Test Procedure for Glutathione Peroxidase (EC 1.11.1.9.) in Blood.” Clinical Chemistry and Laboratory Medicine (CCLM) 12 (10): 444–448. https://doi.org/10.1515/cclm.1974.12.10.444.

Harvard

Günzler, W. A., Kremers, H. and Flohé, L. (1974) ‘An Improved Coupled Test Procedure for Glutathione Peroxidase (EC 1.11.1.9.) in Blood’, Clinical Chemistry and Laboratory Medicine (CCLM), 12(10), pp. 444–448. doi:10.1515/cclm.1974.12.10.444.

IEEE

W. A. Günzler, H. Kremers, and L. Flohé, “An Improved Coupled Test Procedure for Glutathione Peroxidase (EC 1.11.1.9.) in Blood,” Clinical Chemistry and Laboratory Medicine (CCLM), vol. 12, no. 10, pp. 444–448, 1974, doi: 10.1515/cclm.1974.12.10.444.

BibTeX

@article{gunzler1974improved,
  title     = {{An Improved Coupled Test Procedure for Glutathione Peroxidase (EC 1.11.1.9.) in Blood}},
  author    = {Günzler, Wolfgang A. and Kremers, H. and Flohé, Leopold},
  journal   = {Clinical Chemistry and Laboratory Medicine (CCLM)},
  year      = {1974},
  volume    = {12},
  number    = {10},
  pages     = {444--448},
  doi       = {10.1515/cclm.1974.12.10.444},
  url       = {https://doi.org/10.1515/cclm.1974.12.10.444}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
20171313
20181212
201977
20201010
202199
202299
202399
202455
202533
202688

Its field-weighted citation impact is 1.73: it has been cited 1.73 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Nursing › Nutrition and Dietetics › Selenium in Biological Systems

  • glutathione peroxidase
  • coupled enzyme assay
  • tert-butyl hydroperoxide
  • erythrocytes
  • hemoglobin interference
  • cyanmethemoglobin
  • assay optimization

Work with this paper

Most-cited papers in Nursing

All highly cited Nursing papers

Questions about this paper

How do I cite this paper in APA style?

Günzler, W. A., Kremers, H., & Flohé, L. (1974). An Improved Coupled Test Procedure for Glutathione Peroxidase (EC 1.11.1.9.) in Blood. Clinical Chemistry and Laboratory Medicine (CCLM), 12(10), 444–448. https://doi.org/10.1515/cclm.1974.12.10.444

How many times has this paper been cited?

511 times, according to OpenAlex on 20 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at edoc Publication server (Humboldt University of Berlin): sign in and open the PDF from this page.

Who wrote this paper?

Wolfgang A. Günzler, H. Kremers, Leopold Flohé.

What is the DOI of this paper?

10.1515/cclm.1974.12.10.444, permanently at https://doi.org/10.1515/cclm.1974.12.10.444. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 20 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.