Journal article · 2019 · Open access
Evaluation of the cone-beam computed tomography accuracy in measuring soft tissue thickness in different areas of the jaws
Journal of Indian Society of Periodontology, 23(4), 334 · Published 1 July 2019 · DOI 10.4103/jisp.jisp_675_18
In brief
“Evaluation of the cone-beam computed tomography accuracy in measuring soft tissue thickness in different areas of the jaws” is a 2019 journal article by Mohammad Kazemi Ghanbarabadi and 4 co-authors, published in Journal of Indian Society of Periodontology. OpenAlex counts 22 citations as of 18 November 2026, which puts it in the top 7% of works published in 2019 by citations. It is open access under a CC BY-NC-SA licence: the full text is free to read at Journal of Indian Society of Periodontology.
- Citations
- 22
- Most cited in
- 2024 (6)
- Field-weighted impact
- 1.35
- References
- 22
- Authors
- 5
Abstract
PURPOSE: Due to the extensive use of cone-beam computed tomography (CBCT) in dentistry, especially in measuring thicknesses of hard and soft tissues, and the fact that CBCT has low contrast resolution, the aim of this study was to evaluate the accuracy of CBCT in measuring soft tissue thickness. MATERIALS AND METHODS: In this cross-sectional study, pink baseplate wax as a soft tissue simulation was overlaid in different areas of the jaws on the dry human skull, and the probe was used to determine the thicknesses of 1, 2, 3, and 5 mm. These thicknesses were then measured accurately with a digital caliper by one person four times at interval of a week. The skull was scanned using two CBCT scanners, and the different thicknesses of wax were measured by two observers four times with a week interval. The CBCT measurements were compared with digital caliper measurements as a reference. RESULTS: > 0.05). CONCLUSIONS: Statistically, the difference between digital caliper and CBCT measurements was < 0.1 mm, but this difference is not clinically important. The accuracy of CBCT in measuring soft tissue thickness was 0.1 mm.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Ghanbarabadi, M. K., Moudi, E., Haghanifar, S., Johari, M., & Gholinia, H. (2019). Evaluation of the cone-beam computed tomography accuracy in measuring soft tissue thickness in different areas of the jaws. Journal of Indian Society of Periodontology, 23(4), 334. https://doi.org/10.4103/jisp.jisp_675_18
MLA 9
Ghanbarabadi, Mohammad Kazemi, et al. “Evaluation of the cone-beam computed tomography accuracy in measuring soft tissue thickness in different areas of the jaws.” Journal of Indian Society of Periodontology, vol. 23, no. 4, 2019, p. 334. https://doi.org/10.4103/jisp.jisp_675_18.
Chicago
Ghanbarabadi, Mohammad Kazemi, Ehsan Moudi, Sina Haghanifar, Maryam Johari, and Hemmat Gholinia. 2019. “Evaluation of the cone-beam computed tomography accuracy in measuring soft tissue thickness in different areas of the jaws.” Journal of Indian Society of Periodontology 23 (4): 334. https://doi.org/10.4103/jisp.jisp_675_18.
Harvard
Ghanbarabadi, M. K. et al. (2019) ‘Evaluation of the cone-beam computed tomography accuracy in measuring soft tissue thickness in different areas of the jaws’, Journal of Indian Society of Periodontology, 23(4), p. 334. doi:10.4103/jisp.jisp_675_18.
IEEE
M. K. Ghanbarabadi, E. Moudi, S. Haghanifar, M. Johari, and H. Gholinia, “Evaluation of the cone-beam computed tomography accuracy in measuring soft tissue thickness in different areas of the jaws,” Journal of Indian Society of Periodontology, vol. 23, no. 4, p. 334, 2019, doi: 10.4103/jisp.jisp_675_18.
BibTeX
@article{ghanbarabadi2019evaluation,
title = {{Evaluation of the cone-beam computed tomography accuracy in measuring soft tissue thickness in different areas of the jaws}},
author = {Ghanbarabadi, Mohammad Kazemi and Moudi, Ehsan and Haghanifar, Sina and Johari, Maryam and Gholinia, Hemmat},
journal = {Journal of Indian Society of Periodontology},
year = {2019},
volume = {23},
number = {4},
pages = {334},
doi = {10.4103/jisp.jisp_675_18},
url = {https://doi.org/10.4103/jisp.jisp_675_18}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2020 | 2 | |
| 2022 | 3 | |
| 2023 | 4 | |
| 2024 | 6 | |
| 2025 | 3 | |
| 2026 | 4 |
Its field-weighted citation impact is 1.35: it has been cited 1.35 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Health Sciences › Dentistry › Oral Surgery › Dental Radiography and Imaging
- cone-beam computed tomography
- measurement accuracy
- contrast resolution
- dry skulls
- jaw
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Ghanbarabadi, M. K., Moudi, E., Haghanifar, S., Johari, M., & Gholinia, H. (2019). Evaluation of the cone-beam computed tomography accuracy in measuring soft tissue thickness in different areas of the jaws. Journal of Indian Society of Periodontology, 23(4), 334. https://doi.org/10.4103/jisp.jisp_675_18
How many times has this paper been cited?
22 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Journal of Indian Society of Periodontology: sign in and open the full text from this page.
Who wrote this paper?
Mohammad Kazemi Ghanbarabadi, Ehsan Moudi, Sina Haghanifar, Maryam Johari, Hemmat Gholinia.
What is the DOI of this paper?
10.4103/jisp.jisp_675_18, permanently at https://doi.org/10.4103/jisp.jisp_675_18. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.