Dissertation · 2012 · Open access
ACCURACY OF CONE-BEAM COMPUTERIZED TOMOGRAPHY IN DETERMINING THE THICKNESS OF THE PALATAL MASTICATORY MUCOSA
VCU Scholars Compass (Virginia Commonwealth University) · Published 1 January 2012 · DOI 10.25772/q9pv-s502
In brief
“ACCURACY OF CONE-BEAM COMPUTERIZED TOMOGRAPHY IN DETERMINING THE THICKNESS OF THE PALATAL MASTICATORY MUCOSA” is a 2012 dissertation by J. David Hardison, published in VCU Scholars Compass (Virginia Commonwealth University). OpenAlex counts 1 citations as of 18 November 2026. It is open access: the full text is free to read at VCU Scholars Compass (Virginia Commonwealth University).
- Citations
- 1
- Most cited in
- 2022 (1)
- References
- 55
- Authors
- 1
Abstract
BACKGROUND: The aim was to compare the thickness of the palatal masticatory mucosa as determined on a cone-beam computerized (CBCT) scan versus thickness determined via bone-sounding. METHODS: A total of twenty patients requiring palatal surgery participated. Thickness of the palatal tissue was measured at various points radiographically and clinically. The two techniques were compared to determine the agreement of the two measurement modalities. RESULTS: Analysis of variance determined that there was no significant difference between the two methods. A small bias of the radiographic measurement being larger was found to be statistically significant (0.09 ± 0.69mm; p <0.0001). Moreover, the tissue thickness was shown to increase as the distance from the gingival margin increased and the tissue over the molars was thinner than the tissue over the premolars. CONCLUSIONS: CBCT can be used to accurately determine the soft tissue thickness of the palatal masticatory mucosa with minimal bias.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Hardison, J. D. (2012). ACCURACY OF CONE-BEAM COMPUTERIZED TOMOGRAPHY IN DETERMINING THE THICKNESS OF THE PALATAL MASTICATORY MUCOSA. VCU Scholars Compass (Virginia Commonwealth University). https://doi.org/10.25772/q9pv-s502
MLA 9
Hardison, J. David. “ACCURACY OF CONE-BEAM COMPUTERIZED TOMOGRAPHY IN DETERMINING THE THICKNESS OF THE PALATAL MASTICATORY MUCOSA.” VCU Scholars Compass (Virginia Commonwealth University), 2012. https://doi.org/10.25772/q9pv-s502.
Chicago
Hardison, J. David. 2012. “ACCURACY OF CONE-BEAM COMPUTERIZED TOMOGRAPHY IN DETERMINING THE THICKNESS OF THE PALATAL MASTICATORY MUCOSA.” VCU Scholars Compass (Virginia Commonwealth University). https://doi.org/10.25772/q9pv-s502.
Harvard
Hardison, J. D. (2012) ‘ACCURACY OF CONE-BEAM COMPUTERIZED TOMOGRAPHY IN DETERMINING THE THICKNESS OF THE PALATAL MASTICATORY MUCOSA’, VCU Scholars Compass (Virginia Commonwealth University). doi:10.25772/q9pv-s502.
IEEE
J. D. Hardison, “ACCURACY OF CONE-BEAM COMPUTERIZED TOMOGRAPHY IN DETERMINING THE THICKNESS OF THE PALATAL MASTICATORY MUCOSA,” VCU Scholars Compass (Virginia Commonwealth University), 2012, doi: 10.25772/q9pv-s502.
BibTeX
@phdthesis{hardison2012accuracy,
title = {{ACCURACY OF CONE-BEAM COMPUTERIZED TOMOGRAPHY IN DETERMINING THE THICKNESS OF THE PALATAL MASTICATORY MUCOSA}},
author = {Hardison, J. David},
year = {2012},
doi = {10.25772/q9pv-s502},
url = {https://doi.org/10.25772/q9pv-s502}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Health Sciences › Dentistry › Oral Surgery › Dental Radiography and Imaging
- cone-beam computed tomography
- soft tissue thickness
- measurement accuracy
- palatal surgery
- gingival margin
- molars
- premolars
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Hardison, J. D. (2012). ACCURACY OF CONE-BEAM COMPUTERIZED TOMOGRAPHY IN DETERMINING THE THICKNESS OF THE PALATAL MASTICATORY MUCOSA. VCU Scholars Compass (Virginia Commonwealth University). https://doi.org/10.25772/q9pv-s502
How many times has this paper been cited?
1 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at VCU Scholars Compass (Virginia Commonwealth University): sign in and open the PDF from this page.
Who wrote this paper?
J. David Hardison.
What is the DOI of this paper?
10.25772/q9pv-s502, permanently at https://doi.org/10.25772/q9pv-s502. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.