Journal article · 2018 · Open access
Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection
Analytical Chemistry, 91(2), 1578–1586 · Published 13 December 2018 · DOI 10.1021/acs.analchem.8b04877
In brief
“Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection” is a 2018 journal article by Marc Parrilla and 6 co-authors, published in Analytical Chemistry. OpenAlex counts 216 citations as of 18 November 2026. It is open access: the full text is free to read at Analytical Chemistry.
- Citations
- 216
- Most cited in
- 2024 (46)
- Field-weighted impact
- 5.95
- References
- 42
- Authors
- 7
Abstract
A new analytical all-solid-state platform for intradermal potentiometric detection of potassium in interstitial fluid is presented here. Solid microneedles are modified with different coatings and polymeric membranes to prepare both the potassium-selective electrode and reference electrode needed for the potentiometric readout. These microneedle-based electrodes are fixed in an epidermal patch suitable for insertion into the skin. The analytical performances observed for the potentiometric cell (Nernstian slope, limit of detection of 10–4.9 potassium activity, linear range of 10–4.2 to 10–1.1, drift of 0.35 ± 0.28 mV h–1), together with a fast response time, adequate selectivity, and excellent reproducibility and repeatability, are appropriate for potassium analysis in interstitial fluid within both clinical and harmful levels. The potentiometric response is maintained after several insertions into animal skin, confirming the resiliency of the microneedle-based sensor. Ex vivo tests based on the intradermal detection of potassium in chicken and porcine skin demonstrate that the microneedle patch is suitable for monitoring potassium changes inside the skin. In addition, the dimensions of the microneedles modified with the corresponding layers necessary to enhance robustness and provide sensing capabilities (1000 μm length, 45° tip angle, 15 μm thickness in the tip, and 435 μm in the base) agree with the required ranges for a painless insertion into the skin. In vitro cytotoxicity experiments showed that the patch can be used for at least 24 h without any side effect for the skin cells. Overall, the developed concept constitutes important progress in the intradermal analysis of ions related to an electrolyte imbalance in humans, which is relevant for the control of certain types of diseases.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Parrilla, M., Cuartero, M., Sánchez, S. P., Rajabi, M., Roxhed, N., Niklaus, F., & Crespo, G. A. (2018). Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection. Analytical Chemistry, 91(2), 1578–1586. https://doi.org/10.1021/acs.analchem.8b04877
MLA 9
Parrilla, Marc, et al. “Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection.” Analytical Chemistry, vol. 91, no. 2, 2018, pp. 1578–1586. https://doi.org/10.1021/acs.analchem.8b04877.
Chicago
Parrilla, Marc, María Cuartero, Sara Padrell Sánchez, Mina Rajabi, Niclas Roxhed, Frank Niklaus, and Gastón A. Crespo. 2018. “Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection.” Analytical Chemistry 91 (2): 1578–1586. https://doi.org/10.1021/acs.analchem.8b04877.
Harvard
Parrilla, M. et al. (2018) ‘Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection’, Analytical Chemistry, 91(2), pp. 1578–1586. doi:10.1021/acs.analchem.8b04877.
IEEE
M. Parrilla et al., “Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection,” Analytical Chemistry, vol. 91, no. 2, pp. 1578–1586, 2018, doi: 10.1021/acs.analchem.8b04877.
BibTeX
@article{parrilla2018wearable,
title = {{Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection}},
author = {Parrilla, Marc and Cuartero, María and Sánchez, Sara Padrell and Rajabi, Mina and Roxhed, Niclas and Niklaus, Frank and Crespo, Gastón A.},
journal = {Analytical Chemistry},
year = {2018},
volume = {91},
number = {2},
pages = {1578--1586},
doi = {10.1021/acs.analchem.8b04877},
url = {https://doi.org/10.1021/acs.analchem.8b04877}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2018 | 2 | |
| 2019 | 12 | |
| 2020 | 19 | |
| 2021 | 19 | |
| 2022 | 30 | |
| 2023 | 27 | |
| 2024 | 46 | |
| 2025 | 36 | |
| 2026 | 25 |
Its field-weighted citation impact is 5.95: it has been cited 5.95 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- microneedle patch
- potassium ion detection
- interstitial fluid
- potassium ion-selective electrode
- reference electrode
- polymer membranes
- electrolyte imbalance
- Nernstian response
Work with this paper
Most-cited papers in Chemistry
- CRC Handbook of Chemistry and PhysicsW.M. Haynes · CRC Press eBooks · 2014 · 58,210 citations
- Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets: procedure and some applications.Harry Towbin, Th. Staehelin, J Gordon · Proceedings of the National Academy of Sciences · 1979 · 53,242 citations
- Crystal structure refinement with SHELXLGeorge M. Sheldrick · Acta Crystallographica Section C Structural Chemistry · 2014 · 45,305 citations
- Comparison of simple potential functions for simulating liquid waterWilliam L. Jorgensen, Jayaraman Chandrasekhar, Jeffry D. Madura and 2 more · The Journal of Chemical Physics · 1983 · 41,735 citations
- Equation of State Calculations by Fast Computing MachinesN. Metropolis, Arianna W. Rosenbluth, M. N. Rosenbluth and 2 more · The Journal of Chemical Physics · 1953 · 38,111 citations
Questions about this paper
How do I cite this paper in APA style?
Parrilla, M., Cuartero, M., Sánchez, S. P., Rajabi, M., Roxhed, N., Niklaus, F., & Crespo, G. A. (2018). Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection. Analytical Chemistry, 91(2), 1578–1586. https://doi.org/10.1021/acs.analchem.8b04877
How many times has this paper been cited?
216 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Analytical Chemistry: sign in and open the full text from this page.
Who wrote this paper?
Marc Parrilla, María Cuartero, Sara Padrell Sánchez, Mina Rajabi, Niclas Roxhed, Frank Niklaus, Gastón A. Crespo.
What is the DOI of this paper?
10.1021/acs.analchem.8b04877, permanently at https://doi.org/10.1021/acs.analchem.8b04877. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.