Journal article · 2013 · Open access

Voluntary Movement Controlled by the Surface EMG Signal for Tissue-Engineered Skeletal Muscle on a Gripping Tool

Kenichiro Kabumoto, Takayuki Hoshino, Yoshitake Akiyama, Keisuke Morishima

Tissue Engineering Part A, 19(15-16), 1695–1703 · Published 6 June 2013 · DOI 10.1089/ten.tea.2012.0421

Open full textView at the publisherCite this paper

In brief

“Voluntary Movement Controlled by the Surface EMG Signal for Tissue-Engineered Skeletal Muscle on a Gripping Tool” is a 2013 journal article by Kenichiro Kabumoto and 3 co-authors, published in Tissue Engineering Part A. OpenAlex counts 62 citations as of 22 November 2026. It is open access: the full text is free to read at PubMed Central.

Citations
62
Most cited in
2025 (11)
Field-weighted impact
0.62
References
37
Authors
4

Abstract

We have developed a living prosthesis consisting of a living muscle-powered device, which is controlled by neuronal signals to recover some of the functions of a lost extremity. A tissue-engineered skeletal muscle was fabricated with two anchorage points from a primary rat myoblast cultured in a collagen Matrigel mixed gel. Differentiation to the skeletal muscle was confirmed in the tissue-engineered skeletal muscle, and the contraction force increased with increasing frequency of electric stimulation. Then, the tissue-engineered skeletal muscle was assembled into a gripper-type microhand. The tissue-engineered skeletal muscle of the microhand was stimulated electrically, which was then followed by the voluntary movement of the subject's hand. The signal of the surface electromyogram from a subject was processed to mimic the firing spikes of a neuromuscular junction to control the contraction of the tissue-engineered skeletal muscle. The tele-operation of the microhand was demonstrated by optical microscope observations.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Kabumoto, K., Hoshino, T., Akiyama, Y., & Morishima, K. (2013). Voluntary Movement Controlled by the Surface EMG Signal for Tissue-Engineered Skeletal Muscle on a Gripping Tool. Tissue Engineering Part A, 19(15-16), 1695–1703. https://doi.org/10.1089/ten.tea.2012.0421

MLA 9

Kabumoto, Kenichiro, et al. “Voluntary Movement Controlled by the Surface EMG Signal for Tissue-Engineered Skeletal Muscle on a Gripping Tool.” Tissue Engineering Part A, vol. 19, no. 15-16, 2013, pp. 1695–1703. https://doi.org/10.1089/ten.tea.2012.0421.

Chicago

Kabumoto, Kenichiro, Takayuki Hoshino, Yoshitake Akiyama, and Keisuke Morishima. 2013. “Voluntary Movement Controlled by the Surface EMG Signal for Tissue-Engineered Skeletal Muscle on a Gripping Tool.” Tissue Engineering Part A 19 (15-16): 1695–1703. https://doi.org/10.1089/ten.tea.2012.0421.

Harvard

Kabumoto, K. et al. (2013) ‘Voluntary Movement Controlled by the Surface EMG Signal for Tissue-Engineered Skeletal Muscle on a Gripping Tool’, Tissue Engineering Part A, 19(15-16), pp. 1695–1703. doi:10.1089/ten.tea.2012.0421.

IEEE

K. Kabumoto, T. Hoshino, Y. Akiyama, and K. Morishima, “Voluntary Movement Controlled by the Surface EMG Signal for Tissue-Engineered Skeletal Muscle on a Gripping Tool,” Tissue Engineering Part A, vol. 19, no. 15-16, pp. 1695–1703, 2013, doi: 10.1089/ten.tea.2012.0421.

BibTeX

@article{kabumoto2013voluntary,
  title     = {{Voluntary Movement Controlled by the Surface EMG Signal for Tissue-Engineered Skeletal Muscle on a Gripping Tool}},
  author    = {Kabumoto, Kenichiro and Hoshino, Takayuki and Akiyama, Yoshitake and Morishima, Keisuke},
  journal   = {Tissue Engineering Part A},
  year      = {2013},
  volume    = {19},
  number    = {15-16},
  pages     = {1695--1703},
  doi       = {10.1089/ten.tea.2012.0421},
  url       = {https://doi.org/10.1089/ten.tea.2012.0421}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201711
201844
201977
202044
202177
202255
202377
202488
20251111
202622

Its field-weighted citation impact is 0.62: it has been cited 0.62 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering

  • surface electromyography
  • neuromuscular junction
  • electrical stimulation
  • teleoperation
  • voluntary movement

Work with this paper

Most-cited papers in Neuroscience

All highly cited Neuroscience papers

Questions about this paper

How do I cite this paper in APA style?

Kabumoto, K., Hoshino, T., Akiyama, Y., & Morishima, K. (2013). Voluntary Movement Controlled by the Surface EMG Signal for Tissue-Engineered Skeletal Muscle on a Gripping Tool. Tissue Engineering Part A, 19(15-16), 1695–1703. https://doi.org/10.1089/ten.tea.2012.0421

How many times has this paper been cited?

62 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at PubMed Central: sign in and open the full text from this page.

Who wrote this paper?

Kenichiro Kabumoto, Takayuki Hoshino, Yoshitake Akiyama, Keisuke Morishima.

What is the DOI of this paper?

10.1089/ten.tea.2012.0421, permanently at https://doi.org/10.1089/ten.tea.2012.0421. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.