Journal article · 2008 · Open access
Voltammetric Determination of Lead (II) in Medical Lotion and Biological Samples Using Chitosan-Carbon Paste Electrode
International Journal of Electrochemical Science, 3(8), 935–945 · Published 1 August 2008 · DOI 10.1016/s1452-3981(23)15492-7
In brief
“Voltammetric Determination of Lead (II) in Medical Lotion and Biological Samples Using Chitosan-Carbon Paste Electrode” is a 2008 journal article by Rabeay Y. A. Hassan and 2 co-authors, published in International Journal of Electrochemical Science. OpenAlex counts 27 citations as of 22 November 2026. It is open access under a CC BY-NC-ND licence: the full text is free to read at International Journal of Electrochemical Science.
- Citations
- 27
- Most cited in
- 2015 (4)
- Field-weighted impact
- 1.70
- References
- 18
- Authors
- 3
Abstract
A simple method for anodic stripping voltammetric determination of lead using carbon paste electrode modified with biomolecular chitosan, is described. In this method, the electrode is activated electrochemically by 5 replicated scanning over the potential range –1000 to –400 mV in 0.5 M HCl solution. Following this step, the lead sample containing 0.1 M KCl solution as supporting electrolyte is purged by nitrogen gas for 2 min, pre-concentrated on the activated electrode at –1000 mV for 30 s. The deposited metal is then oxidized by different modes of sweep in the oxidation direction. Chemical and electrical parameters affecting the voltammetric measurements are optimized. The peak current is proportional to the Pb(II) concentration in a range 10-110 ng/ml, with detection limit 2 ng/m using differential pulse mode. The relative standard deviation is 1.96% for 10 ng/ml (five replicates). The proposed method is applied to the determination of Pb(II) in acidified samples of tap water, pharmaceutical preparations, human blood and urine with satisfactory results. No interference due to 10 fold excess of Cd, Tl, Sn and Cu is observed. The result obtained by the modified electrode is more accurate and selective than the unmodified electrode.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Hassan, R. Y. A., Habib, I. H., & Hassan, H. (2008). Voltammetric Determination of Lead (II) in Medical Lotion and Biological Samples Using Chitosan-Carbon Paste Electrode. International Journal of Electrochemical Science, 3(8), 935–945. https://doi.org/10.1016/s1452-3981(23)15492-7
MLA 9
Hassan, Rabeay Y. A., et al. “Voltammetric Determination of Lead (II) in Medical Lotion and Biological Samples Using Chitosan-Carbon Paste Electrode.” International Journal of Electrochemical Science, vol. 3, no. 8, 2008, pp. 935–945. https://doi.org/10.1016/s1452-3981(23)15492-7.
Chicago
Hassan, Rabeay Y. A., Ibrahim H.I. Habib, and Hassan Hassan. 2008. “Voltammetric Determination of Lead (II) in Medical Lotion and Biological Samples Using Chitosan-Carbon Paste Electrode.” International Journal of Electrochemical Science 3 (8): 935–945. https://doi.org/10.1016/s1452-3981(23)15492-7.
Harvard
Hassan, R. Y. A., Habib, I. H. and Hassan, H. (2008) ‘Voltammetric Determination of Lead (II) in Medical Lotion and Biological Samples Using Chitosan-Carbon Paste Electrode’, International Journal of Electrochemical Science, 3(8), pp. 935–945. doi:10.1016/s1452-3981(23)15492-7.
IEEE
R. Y. A. Hassan, I. H. Habib, and H. Hassan, “Voltammetric Determination of Lead (II) in Medical Lotion and Biological Samples Using Chitosan-Carbon Paste Electrode,” International Journal of Electrochemical Science, vol. 3, no. 8, pp. 935–945, 2008, doi: 10.1016/s1452-3981(23)15492-7.
BibTeX
@article{hassan2008voltammetric,
title = {{Voltammetric Determination of Lead (II) in Medical Lotion and Biological Samples Using Chitosan-Carbon Paste Electrode}},
author = {Hassan, Rabeay Y. A. and Habib, Ibrahim H.I. and Hassan, Hassan},
journal = {International Journal of Electrochemical Science},
year = {2008},
volume = {3},
number = {8},
pages = {935--945},
doi = {10.1016/s1452-3981(23)15492-7},
url = {https://doi.org/10.1016/s1452-3981(23)15492-7}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2012 | 3 | |
| 2013 | 3 | |
| 2014 | 2 | |
| 2015 | 4 | |
| 2016 | 1 | |
| 2018 | 2 | |
| 2019 | 1 | |
| 2021 | 1 | |
| 2023 | 1 | |
| 2026 | 1 |
Its field-weighted citation impact is 1.70: it has been cited 1.70 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- lead(II) determination
- anodic stripping voltammetry
- human blood
- urine
- tap water
- pharmaceutical preparations
- differential pulse voltammetry
- heavy metal detection
Work with this paper
Most-cited papers in Chemistry
- CRC Handbook of Chemistry and PhysicsW.M. Haynes · CRC Press eBooks · 2014 · 58,210 citations
- Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets: procedure and some applications.Harry Towbin, Th. Staehelin, J Gordon · Proceedings of the National Academy of Sciences · 1979 · 53,242 citations
- Crystal structure refinement with SHELXLGeorge M. Sheldrick · Acta Crystallographica Section C Structural Chemistry · 2014 · 45,305 citations
- Comparison of simple potential functions for simulating liquid waterWilliam L. Jorgensen, Jayaraman Chandrasekhar, Jeffry D. Madura and 2 more · The Journal of Chemical Physics · 1983 · 41,735 citations
- Equation of State Calculations by Fast Computing MachinesN. Metropolis, Arianna W. Rosenbluth, M. N. Rosenbluth and 2 more · The Journal of Chemical Physics · 1953 · 38,111 citations
Questions about this paper
How do I cite this paper in APA style?
Hassan, R. Y. A., Habib, I. H., & Hassan, H. (2008). Voltammetric Determination of Lead (II) in Medical Lotion and Biological Samples Using Chitosan-Carbon Paste Electrode. International Journal of Electrochemical Science, 3(8), 935–945. https://doi.org/10.1016/s1452-3981(23)15492-7
How many times has this paper been cited?
27 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at International Journal of Electrochemical Science: sign in and open the full text from this page.
Who wrote this paper?
Rabeay Y. A. Hassan, Ibrahim H.I. Habib, Hassan Hassan.
What is the DOI of this paper?
10.1016/s1452-3981(23)15492-7, permanently at https://doi.org/10.1016/s1452-3981(23)15492-7. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.