“Using Graphene Liquid Cell Transmission Electron Microscopy to Study in Situ Nanocrystal Etching” is a 2018 journal article by Matthew R. Hauwiller and 2 co-authors, published in Journal of Visualized Experiments. OpenAlex counts 51 citations as of 16 November 2026. It is open access: the full text is free to read at Journal of Visualized Experiments.
- Citations
- 51
- Most cited in
- 2021 (9)
- Field-weighted impact
- 2.72
- References
- 40
- Authors
- 3
Abstract
Graphene liquid cell electron microscopy provides the ability to observe nanoscale chemical transformations and dynamics as the reactions are occurring in liquid environments. This manuscript describes the process for making graphene liquid cells through the example of graphene liquid cell transmission electron microscopy (TEM) experiments of gold nanocrystal etching. The protocol for making graphene liquid cells involves coating gold, holey-carbon TEM grids with chemical vapor deposition graphene and then using those graphene-coated grids to encapsulate liquid between two graphene surfaces. These pockets of liquid, with the nanomaterial of interest, are imaged in the electron microscope to see the dynamics of the nanoscale process, in this case the oxidative etching of gold nanorods. By controlling the electron beam dose rate, which modulates the etching species in the liquid cell, the underlying mechanisms of how atoms are removed from nanocrystals to form different facets and shapes can be better understood. Graphene liquid cell TEM has the advantages of high spatial resolution, compatibility with traditional TEM holders, and low start-up costs for research groups. Current limitations include delicate sample preparation, lack of flow capability, and reliance on electron beam-generated radiolysis products to induce reactions. With further development and control, graphene liquid cell may become a ubiquitous technique in nanomaterials and biology, and is already being used to study mechanisms governing growth, etching, and self-assembly processes of nanomaterials in liquid on the single particle level.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Hauwiller, M. R., Ondry, J. C., & Alivisatos, A. P. (2018). Using Graphene Liquid Cell Transmission Electron Microscopy to Study in Situ Nanocrystal Etching. Journal of Visualized Experiments. https://doi.org/10.3791/57665-v
MLA 9
Hauwiller, Matthew R., et al. “Using Graphene Liquid Cell Transmission Electron Microscopy to Study in Situ Nanocrystal Etching.” Journal of Visualized Experiments, no. 135, 2018. https://doi.org/10.3791/57665-v.
Chicago
Hauwiller, Matthew R., Justin C. Ondry, and A. Paul Alivisatos. 2018. “Using Graphene Liquid Cell Transmission Electron Microscopy to Study in Situ Nanocrystal Etching.” Journal of Visualized Experiments (135). https://doi.org/10.3791/57665-v.
Harvard
Hauwiller, M. R., Ondry, J. C. and Alivisatos, A. P. (2018) ‘Using Graphene Liquid Cell Transmission Electron Microscopy to Study in Situ Nanocrystal Etching’, Journal of Visualized Experiments. doi:10.3791/57665-v.
IEEE
M. R. Hauwiller, J. C. Ondry, and A. P. Alivisatos, “Using Graphene Liquid Cell Transmission Electron Microscopy to Study in Situ Nanocrystal Etching,” Journal of Visualized Experiments, no. 135, 2018, doi: 10.3791/57665-v.
BibTeX
@article{hauwiller2018using,
title = {{Using Graphene Liquid Cell Transmission Electron Microscopy to Study in Situ Nanocrystal Etching}},
author = {Hauwiller, Matthew R. and Ondry, Justin C. and Alivisatos, A. Paul},
journal = {Journal of Visualized Experiments},
year = {2018},
number = {135},
doi = {10.3791/57665-v},
url = {https://doi.org/10.3791/57665-v}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2016 | 1 | |
| 2018 | 5 | |
| 2019 | 6 | |
| 2020 | 4 | |
| 2021 | 9 | |
| 2022 | 3 | |
| 2023 | 9 | |
| 2024 | 4 | |
| 2025 | 7 | |
| 2026 | 3 |
Its field-weighted citation impact is 2.72: it has been cited 2.72 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Life Sciences › Biochemistry, Genetics and Molecular Biology › Structural Biology › Advanced Electron Microscopy Techniques and Applications
- graphene liquid cell
- in situ electron microscopy
- gold nanorods
- oxidative etching
- facet formation
- CVD graphene
- radiolysis
Work with this paper
Most-cited papers in Biochemistry, Genetics and Molecular Biology
- PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENTOliver H. Lowry, NiraJ. Rosebrough, A. Lewis Farr and 1 more · Journal of Biological Chemistry · 1951 · 316,470 citations
- A Rapid and Sensitive Method for the Quantitation of Microgram Quantities of Protein Utilizing the Principle of Protein-Dye BindingM Bradford · Analytical Biochemistry · 1976 · 256,780 citations
- Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT MethodKenneth J. Livak, Thomas D. Schmittgen · Methods · 2001 · 184,418 citations
- Molecular Cloning: A Laboratory ManualJoseph Sambrook, Elisabeth Fritsch, Tom Maniatis · UCLA - Biblioteca de Ciencias de la Salud · 1989 · 133,493 citations
- Basic Local Alignment Search ToolStephen F. Altschul, Warren R. Gish, Webb Miller and 2 more · Journal of Molecular Biology · 1990 · 100,529 citations
All highly cited Biochemistry, Genetics and Molecular Biology papers
Questions about this paper
How do I cite this paper in APA style?
Hauwiller, M. R., Ondry, J. C., & Alivisatos, A. P. (2018). Using Graphene Liquid Cell Transmission Electron Microscopy to Study in Situ Nanocrystal Etching. Journal of Visualized Experiments. https://doi.org/10.3791/57665-v
How many times has this paper been cited?
51 times, according to OpenAlex on 16 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access: read the free full text at Journal of Visualized Experiments.
Who wrote this paper?
Matthew R. Hauwiller, Justin C. Ondry, A. Paul Alivisatos.
What is the DOI of this paper?
10.3791/57665-v. The permanent link is https://doi.org/10.3791/57665-v.
Bibliographic data from OpenAlex (CC0), last checked 16 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.