Journal article · 2025 · Open access
Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro study
Journal of Dentistry, 165, 106269 · Published 28 November 2025 · DOI 10.1016/j.jdent.2025.106269
In brief
“Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro study” is a 2025 journal article by Francesco Guido Mangano and 5 co-authors, published in Journal of Dentistry. OpenAlex counts 19 citations as of 17 November 2026, which puts it in the top 1% of works published in 2025 by citations. It is open access under a CC BY licence: the full text is free to read at Journal of Dentistry.
- Citations
- 19
- Most cited in
- 2026 (19)
- Field-weighted impact
- 12.77
- References
- 43
- Authors
- 6
Abstract
OBJECTIVE: To compare the trueness of extraoral photogrammetry (EPG), intraoral photogrammetry (IPG), and four intraoral scanners (IOSs) in capturing a completely edentulous model with six implant analogs. METHODS: A type IV plaster master model containing six implant analogs was digitized using a coordinate measuring machine (CMM) to obtain the reference dataset. The model was then scanned with two photogrammetric systems-an extraoral device (3Dots®) and an IOS equipped with IPG (Aoralscan Elite IPG®)-as well as four IOSs (TRIOS 6®, CS 3800®, iTero Lumina™, i900®). Ten scans per IOS were performed under standardized conditions. All datasets were processed in CAD software to replace scanbodies (SBs) with their corresponding library geometries and analyzed in reverse-engineering software to measure inter-implant distances. Absolute deviations from CMM data were used to assess trueness. Statistical analysis included descriptive statistics and repeated measures ANOVA with Bonferroni correction (α = 0.05). RESULTS: EPG demonstrated the highest trueness (mean deviation 5 μm), followed by IPG (29 μm) and iTero Lumina™ (34 μm). The i900® (54 μm), TRIOS 6® (84 μm), and CS 3800® (223 μm) exhibited progressively greater deviations. No significant differences were observed among EPG, IPG, and iTero Lumina™, which all outperformed TRIOS 6® (p ≤ 0.020) and CS 3800® (p < .001). Medit i900® and TRIOS 6® were also significantly more accurate than CS 3800® (p < .001). Segment-level analysis revealed higher deviations for longer inter-implant spans. CONCLUSIONS: Within the limits of this study, EPG achieved the highest accuracy and remains the reference method for full-arch implant digitization. IPG and iTero Lumina™ reached comparably high trueness, followed by Medit i900® and TRIOS 6®. CLINICAL RELEVANCE: Next-generation IOSs, particularly iTero Lumina™, may approach the trueness of photogrammetric systems, although photogrammetry-especially EPG-remains the most accurate option for digital full-arch implant acquisition.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Mangano, F. G., Lerner, H., Valle, G., Biaggini, F., Mangano, C., & Dybov, A. M. (2025). Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro study. Journal of Dentistry, 165, 106269. https://doi.org/10.1016/j.jdent.2025.106269
MLA 9
Mangano, Francesco Guido, et al. “Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro study.” Journal of Dentistry, vol. 165, 2025, p. 106269. https://doi.org/10.1016/j.jdent.2025.106269.
Chicago
Mangano, Francesco Guido, Henriette Lerner, Gabriele Valle, Francesco Biaggini, Carlo Mangano, and Andrey Mikhailovich Dybov. 2025. “Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro study.” Journal of Dentistry 165: 106269. https://doi.org/10.1016/j.jdent.2025.106269.
Harvard
Mangano, F. G. et al. (2025) ‘Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro study’, Journal of Dentistry, 165, p. 106269. doi:10.1016/j.jdent.2025.106269.
IEEE
F. G. Mangano, H. Lerner, G. Valle, F. Biaggini, C. Mangano, and A. M. Dybov, “Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro study,” Journal of Dentistry, vol. 165, p. 106269, 2025, doi: 10.1016/j.jdent.2025.106269.
BibTeX
@article{mangano2025trueness,
title = {{Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro study}},
author = {Mangano, Francesco Guido and Lerner, Henriette and Valle, Gabriele and Biaggini, Francesco and Mangano, Carlo and Dybov, Andrey Mikhailovich},
journal = {Journal of Dentistry},
year = {2025},
volume = {165},
pages = {106269},
doi = {10.1016/j.jdent.2025.106269},
url = {https://doi.org/10.1016/j.jdent.2025.106269}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- intraoral scanning
- digital implant impressions
- trueness
- implant analogs
- inter-implant distance
- coordinate measuring machine
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Mangano, F. G., Lerner, H., Valle, G., Biaggini, F., Mangano, C., & Dybov, A. M. (2025). Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro study. Journal of Dentistry, 165, 106269. https://doi.org/10.1016/j.jdent.2025.106269
How many times has this paper been cited?
19 times, according to OpenAlex on 17 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Journal of Dentistry: sign in and open the full text from this page.
Who wrote this paper?
Francesco Guido Mangano, Henriette Lerner, Gabriele Valle, Francesco Biaggini, Carlo Mangano, Andrey Mikhailovich Dybov.
What is the DOI of this paper?
10.1016/j.jdent.2025.106269, permanently at https://doi.org/10.1016/j.jdent.2025.106269. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 17 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.