Journal article · 2020 · Open access
Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
BMC Oral Health, 20(1), 263 · Published 22 September 2020 · DOI 10.1186/s12903-020-01254-9
In brief
“Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study” is a 2020 journal article by Francesco Guido Mangano and 5 co-authors, published in BMC Oral Health. OpenAlex counts 209 citations as of 27 November 2026, which puts it in the top 5% of works published in 2020 by citations. It is open access under a CC BY licence: the full text is free to read at BMC Oral Health.
- Citations
- 209
- Most cited in
- 2022 (42)
- Field-weighted impact
- 22.44
- References
- 41
- Authors
- 6
Abstract
BACKGROUND: The literature has not yet validated the use of intraoral scanners (IOSs) for full-arch (FA) implant impression. Hence, the aim of this in vitro study was to assess and compare the trueness of 12 different IOSs in FA implant impression. METHODS: A stone-cast model of a totally edentulous maxilla with 6 implant analogues and scanbodies (SBs) was scanned with a desktop scanner (Freedom UHD®) to capture a reference model (RM), and with 12 IOSs (ITERO ELEMENTS 5D®; PRIMESCAN® and OMNICAM®; CS 3700® and CS 3600®; TRIOS3®; i-500®; EMERALD S® and EMERALD®; VIRTUO VIVO® and DWIO®; RUNEYES QUICKSCAN®). Ten scans were taken using each IOS, and each was compared to the RM, to evaluate trueness. A mesh/mesh method and a nurbs/nurbs method were used to evaluate the overall trueness of the scans; linear and cross distances between the SBs were used to evaluate the local trueness of the scans. The analysis was performed using reverse engineering software (Studio®, Geomagics; Magics®, Materialise). A statistical evaluation was performed. RESULTS: With the mesh/mesh method, the best results were obtained by CS 3700® (mean error 30.4 μm) followed by ITERO ELEMENTS 5D® (31.4 μm), i-500® (32.2 μm), TRIOS 3® (36.4 μm), CS 3600® (36.5 μm), PRIMESCAN® (38.4 μm), VIRTUO VIVO® (43.8 μm), RUNEYES® (44.4 μm), EMERALD S® (52.9 μm), EMERALD® (76.1 μm), OMNICAM® (79.6 μm) and DWIO® (98.4 μm). With the nurbs/nurbs method, the best results were obtained by ITERO ELEMENTS 5D® (mean error 16.1 μm), followed by PRIMESCAN® (19.3 μm), TRIOS 3® (20.2 μm), i-500® (20.8 μm), CS 3700® (21.9 μm), CS 3600® (24.4 μm), VIRTUO VIVO® (32.0 μm), RUNEYES® (33.9 μm), EMERALD S® (36.8 μm), OMNICAM® (47.0 μm), EMERALD® (51.9 μm) and DWIO® (69.9 μm). Statistically significant differences were found between the IOSs. Linear and cross distances between the SBs (local trueness analysis) confirmed the data that emerged from the overall trueness evaluation. CONCLUSIONS: Different levels of trueness were found among the IOSs evaluated in this study. Further studies are needed to confirm these results.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Mangano, F. G., Admakin, O. I., Bonacina, M., Lerner, H., Rutkūnas, V., & Mangano, C. (2020). Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study. BMC Oral Health, 20(1), 263. https://doi.org/10.1186/s12903-020-01254-9
MLA 9
Mangano, Francesco Guido, et al. “Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study.” BMC Oral Health, vol. 20, no. 1, 2020, p. 263. https://doi.org/10.1186/s12903-020-01254-9.
Chicago
Mangano, Francesco Guido, Oleg Ivanovich Admakin, Matteo Bonacina, Henriette Lerner, Vygandas Rutkūnas, and Carlo Mangano. 2020. “Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study.” BMC Oral Health 20 (1): 263. https://doi.org/10.1186/s12903-020-01254-9.
Harvard
Mangano, F. G. et al. (2020) ‘Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study’, BMC Oral Health, 20(1), p. 263. doi:10.1186/s12903-020-01254-9.
IEEE
F. G. Mangano, O. I. Admakin, M. Bonacina, H. Lerner, V. Rutkūnas, and C. Mangano, “Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study,” BMC Oral Health, vol. 20, no. 1, p. 263, 2020, doi: 10.1186/s12903-020-01254-9.
BibTeX
@article{mangano2020trueness,
title = {{Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study}},
author = {Mangano, Francesco Guido and Admakin, Oleg Ivanovich and Bonacina, Matteo and Lerner, Henriette and Rutkūnas, Vygandas and Mangano, Carlo},
journal = {BMC Oral Health},
year = {2020},
volume = {20},
number = {1},
pages = {263},
doi = {10.1186/s12903-020-01254-9},
url = {https://doi.org/10.1186/s12903-020-01254-9}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2020 | 3 | |
| 2021 | 24 | |
| 2022 | 42 | |
| 2023 | 34 | |
| 2024 | 40 | |
| 2025 | 41 | |
| 2026 | 25 |
Its field-weighted citation impact is 22.44: it has been cited 22.44 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- intraoral scanners
- trueness
- accuracy
- dental implants
- mesh comparison
- reverse engineering
- digital dentistry
- scanner comparison
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Mangano, F. G., Admakin, O. I., Bonacina, M., Lerner, H., Rutkūnas, V., & Mangano, C. (2020). Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study. BMC Oral Health, 20(1), 263. https://doi.org/10.1186/s12903-020-01254-9
How many times has this paper been cited?
209 times, according to OpenAlex on 27 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at BMC Oral Health: sign in and open the PDF from this page.
Who wrote this paper?
Francesco Guido Mangano, Oleg Ivanovich Admakin, Matteo Bonacina, Henriette Lerner, Vygandas Rutkūnas, Carlo Mangano.
What is the DOI of this paper?
10.1186/s12903-020-01254-9, permanently at https://doi.org/10.1186/s12903-020-01254-9. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 27 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.