Journal article · 2005 · Open access
Tomographic Imaging with Single Atom Sensitivity Using Aberration-Corrected STEM
Microscopy and Microanalysis, 11(S02) · Published 1 August 2005 · DOI 10.1017/s143192760550223x
In brief
“Tomographic Imaging with Single Atom Sensitivity Using Aberration-Corrected STEM” is a 2005 journal article by Klaus van Benthem and 3 co-authors, published in Microscopy and Microanalysis. OpenAlex counts 0 citations as of 19 November 2026. It is open access: the full text is free to read at Microscopy and Microanalysis.
- Citations
- 0
- References
- 2
- Authors
- 4
Abstract
The distribution of single dopant atoms can dramatically alter the properties of semiconductors and catalysts, which are arguably the two most important classes of modern materials.The detectability and lateral localization of such single atoms has been greatly improved by the recent development of aberration correction in scanning transmission electron microscopy (STEM) [1], which enables the formation of electron probes with diameters that can be as small as 0.06-0.08nm [2].We take advantage of a previously unappreciated effect of aberration correction, the increase in depth resolution.By consecutively focusing the electron probe into different planes of the specimen, a slice-by-slice image of the three-dimensional structure is available, which is realized by recording through-focal series (see Figure 1).The recorded image stacks can then be used for 3-D reconstructions.We show how the improved vertical resolution along with sub-Ångstrom lateral resolution enables the direct and unequivocal three-dimensional location of single Hf atoms inside a semiconductor device structure.The Hf atoms are visible in a narrow SiO 2 layer located between a single-crystalline Si wafer and a polycrystalline HfO 2 dielectric film, but are not in contact with the Si substrate (see Figure 2a).All individual Hf atoms remain at least 0.3 nm away from the Si/SiO 2 interface.This atom by atom characterization of semiconductor interfaces in all three dimensions is a critical capability for the prediction of gate-dielectric properties and the design of new semiconductor devices.In a second example, we show three-dimensional data sets obtained from Au nano-crystals on a carbon support film.Isolated Au atoms beside some Au clusters indicate the vertical position of the support film (cf. Figure 2b).The threedimensional shape of the Au clusters can be determined by a combination with image simulations [3].
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
van Benthem, K., Lupini, A. R., Peng, Y., & Pennycook, S. J. (2005). Tomographic Imaging with Single Atom Sensitivity Using Aberration-Corrected STEM. Microscopy and Microanalysis, 11(S02). https://doi.org/10.1017/s143192760550223x
MLA 9
van Benthem, Klaus, et al. “Tomographic Imaging with Single Atom Sensitivity Using Aberration-Corrected STEM.” Microscopy and Microanalysis, vol. 11, no. S02, 2005. https://doi.org/10.1017/s143192760550223x.
Chicago
van Benthem, Klaus, Andrew R. Lupini, Yingquan Peng, and Stephen John Pennycook. 2005. “Tomographic Imaging with Single Atom Sensitivity Using Aberration-Corrected STEM.” Microscopy and Microanalysis 11 (S02). https://doi.org/10.1017/s143192760550223x.
Harvard
van Benthem, K. et al. (2005) ‘Tomographic Imaging with Single Atom Sensitivity Using Aberration-Corrected STEM’, Microscopy and Microanalysis, 11(S02). doi:10.1017/s143192760550223x.
IEEE
K. van Benthem, A. R. Lupini, Y. Peng, and S. J. Pennycook, “Tomographic Imaging with Single Atom Sensitivity Using Aberration-Corrected STEM,” Microscopy and Microanalysis, vol. 11, no. S02, 2005, doi: 10.1017/s143192760550223x.
BibTeX
@article{vanbenthem2005tomographic,
title = {{Tomographic Imaging with Single Atom Sensitivity Using Aberration-Corrected STEM}},
author = {van Benthem, Klaus and Lupini, Andrew R. and Peng, Yingquan and Pennycook, Stephen John},
journal = {Microscopy and Microanalysis},
year = {2005},
volume = {11},
number = {S02},
doi = {10.1017/s143192760550223x},
url = {https://doi.org/10.1017/s143192760550223x}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Life Sciences › Biochemistry, Genetics and Molecular Biology › Structural Biology › Advanced Electron Microscopy Techniques and Applications
- single-atom imaging
- aberration-corrected STEM
- tomography
- depth resolution
- 3D reconstruction
- Si/SiO2 interface
- gate dielectric
- Au nanoparticles
Work with this paper
Most-cited papers in Biochemistry, Genetics and Molecular Biology
- PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENTOliver H. Lowry, NiraJ. Rosebrough, A. Lewis Farr and 1 more · Journal of Biological Chemistry · 1951 · 316,470 citations
- A Rapid and Sensitive Method for the Quantitation of Microgram Quantities of Protein Utilizing the Principle of Protein-Dye BindingM Bradford · Analytical Biochemistry · 1976 · 256,780 citations
- Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT MethodKenneth J. Livak, Thomas D. Schmittgen · Methods · 2001 · 184,418 citations
- Molecular Cloning: A Laboratory ManualJoseph Sambrook, Elisabeth Fritsch, Tom Maniatis · UCLA - Biblioteca de Ciencias de la Salud · 1989 · 133,493 citations
- Basic Local Alignment Search ToolStephen F. Altschul, Warren R. Gish, Webb Miller and 2 more · Journal of Molecular Biology · 1990 · 100,529 citations
All highly cited Biochemistry, Genetics and Molecular Biology papers
Questions about this paper
How do I cite this paper in APA style?
van Benthem, K., Lupini, A. R., Peng, Y., & Pennycook, S. J. (2005). Tomographic Imaging with Single Atom Sensitivity Using Aberration-Corrected STEM. Microscopy and Microanalysis, 11(S02). https://doi.org/10.1017/s143192760550223x
How many times has this paper been cited?
0 times, according to OpenAlex on 19 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Microscopy and Microanalysis: sign in and open the PDF from this page.
Who wrote this paper?
Klaus van Benthem, Andrew R. Lupini, Yingquan Peng, Stephen John Pennycook.
What is the DOI of this paper?
10.1017/s143192760550223x, permanently at https://doi.org/10.1017/s143192760550223x. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 19 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.