Conference paper · 2023 · Open access

The Robotic Socket: A Robotic Design and Biomimetic Application of an Auto-Adjusting Prosthetic Socket Prototype for Above-Knee Amputees

Michael Rose, Olivia Carnochan, Rhys Gamlin, Liam Tomlinson, Aghil Jafari, Appolinaire Etoundi

IEEE International Conference on Robotics and Biomimetics (ROBIO), 1–6 · Published 4 December 2023 · DOI 10.1109/robio58561.2023.10354965

Open PDFView at the publisherCite this paper

In brief

“The Robotic Socket: A Robotic Design and Biomimetic Application of an Auto-Adjusting Prosthetic Socket Prototype for Above-Knee Amputees” is a 2023 conference paper by Michael Rose and 5 co-authors, published in IEEE International Conference on Robotics and Biomimetics (ROBIO). OpenAlex counts 2 citations as of 22 November 2026, which puts it in the top 8% of works published in 2023 by citations. It is open access under a CC BY licence: the full text is free to read at UWE Research Repository (UWE Bristol).

Citations
2
Most cited in
2025 (2)
Field-weighted impact
0.77
References
10
Authors
6

Abstract

Comfort in prosthetic sockets remains a significant challenge for many amputees, particularly for above-knee amputees bearing substantial weight on their soft tissue [1], [2]. The predominant source of discomfort often originates from swelling of the residual limb, a factor traditional prosthetic sockets fail to accommodate [3]. While Osseointegration surgery, a unique method to connect prosthetics and residual limbs while removing the socket, is recognized as a superior solution for enhancing comfort and quality of life, its accessibility remains limited [4]. Hence, the motivation for this study is to explore the development of an automatically actuating and adjustable socket. This research aims to design and develop a prosthetic limb socket offering enhanced comfort, flexibility, and user control i.e. a robotic socket (RS). A comprehensive literature review was conducted to assess existing interactive sockets and sensory systems, focusing on their performance and specifications. The methodology employed in this study (Phase 1) involved the design and testing of small-scale circuits which will later (Phase 2) evolve into a more complex and up-scaled system. The prototype developed in this study features a plastic bottle equipped with a pressure valve, simulating residual limb swelling by modulating the internal pressure. A 3D-printed button and locking wire serve as a rigid socket, preventing unchecked bottle expansion. A motor integrated into the system modulates hoop tension on the conceptual socket, ensuring user-specific pressure regulation. The system was developed using a Raspberry Pi to manage motor fluctuations based on user-defined set points and bottle pressure readings. Preliminary testing demonstrated promising results, with the motor effectively adjusting the cable tension in response to the pressure sensor’s readings. The use of a plastic bottle in the prototype makes this design cost-effective and accessible.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Rose, M., Carnochan, O., Gamlin, R., Tomlinson, L., Jafari, A., & Etoundi, A. (2023). The Robotic Socket: A Robotic Design and Biomimetic Application of an Auto-Adjusting Prosthetic Socket Prototype for Above-Knee Amputees. IEEE International Conference on Robotics and Biomimetics (ROBIO), 1–6. https://doi.org/10.1109/robio58561.2023.10354965

MLA 9

Rose, Michael, et al. “The Robotic Socket: A Robotic Design and Biomimetic Application of an Auto-Adjusting Prosthetic Socket Prototype for Above-Knee Amputees.” IEEE International Conference on Robotics and Biomimetics (ROBIO), 2023, pp. 1–6. https://doi.org/10.1109/robio58561.2023.10354965.

Chicago

Rose, Michael, Olivia Carnochan, Rhys Gamlin, Liam Tomlinson, Aghil Jafari, and Appolinaire Etoundi. 2023. “The Robotic Socket: A Robotic Design and Biomimetic Application of an Auto-Adjusting Prosthetic Socket Prototype for Above-Knee Amputees.” IEEE International Conference on Robotics and Biomimetics (ROBIO): 1–6. https://doi.org/10.1109/robio58561.2023.10354965.

Harvard

Rose, M. et al. (2023) ‘The Robotic Socket: A Robotic Design and Biomimetic Application of an Auto-Adjusting Prosthetic Socket Prototype for Above-Knee Amputees’, IEEE International Conference on Robotics and Biomimetics (ROBIO), pp. 1–6. doi:10.1109/robio58561.2023.10354965.

IEEE

M. Rose, O. Carnochan, R. Gamlin, L. Tomlinson, A. Jafari, and A. Etoundi, “The Robotic Socket: A Robotic Design and Biomimetic Application of an Auto-Adjusting Prosthetic Socket Prototype for Above-Knee Amputees,” IEEE International Conference on Robotics and Biomimetics (ROBIO), pp. 1–6, 2023, doi: 10.1109/robio58561.2023.10354965.

BibTeX

@inproceedings{rose2023robotic,
  title     = {{The Robotic Socket: A Robotic Design and Biomimetic Application of an Auto-Adjusting Prosthetic Socket Prototype for Above-Knee Amputees}},
  author    = {Rose, Michael and Carnochan, Olivia and Gamlin, Rhys and Tomlinson, Liam and Jafari, Aghil and Etoundi, Appolinaire},
  booktitle = {IEEE International Conference on Robotics and Biomimetics (ROBIO)},
  year      = {2023},
  pages     = {1--6},
  doi       = {10.1109/robio58561.2023.10354965},
  url       = {https://doi.org/10.1109/robio58561.2023.10354965}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics

  • prosthetic socket
  • transfemoral amputation
  • socket comfort
  • hoop stress
  • pressure sensors
  • motor actuation
  • Raspberry Pi
  • 3D printing

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Rose, M., Carnochan, O., Gamlin, R., Tomlinson, L., Jafari, A., & Etoundi, A. (2023). The Robotic Socket: A Robotic Design and Biomimetic Application of an Auto-Adjusting Prosthetic Socket Prototype for Above-Knee Amputees. IEEE International Conference on Robotics and Biomimetics (ROBIO), 1–6. https://doi.org/10.1109/robio58561.2023.10354965

How many times has this paper been cited?

2 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at UWE Research Repository (UWE Bristol): sign in and open the PDF from this page.

Who wrote this paper?

Michael Rose, Olivia Carnochan, Rhys Gamlin, Liam Tomlinson, Aghil Jafari, Appolinaire Etoundi.

What is the DOI of this paper?

10.1109/robio58561.2023.10354965, permanently at https://doi.org/10.1109/robio58561.2023.10354965. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.