Journal article · 2019 · Open access
The Preparation and Properties of Multilayer Cu-MTa2O5 Composite Coatings on Ti6Al4V for Biomedical Applications
Nanomaterials, 9(10), 1498 · Published 21 October 2019 · DOI 10.3390/nano9101498
In brief
“The Preparation and Properties of Multilayer Cu-MTa2O5 Composite Coatings on Ti6Al4V for Biomedical Applications” is a 2019 journal article by Zeliang Ding and 7 co-authors, published in Nanomaterials. OpenAlex counts 18 citations as of 17 November 2026. It is open access under a CC BY licence: the full text is free to read at Nanomaterials.
- Citations
- 18
- Most cited in
- 2023 (5)
- Field-weighted impact
- 0.68
- References
- 85
- Authors
- 8
Abstract
For the enhancement of the anticorrosion and antibacterial performance of the biomedical alloy Ti6Al4V, a novel Cu incorporated multilayer Ta2O5ceramic composite coating Cu-Ta2O5/Ta2O5/Ta2O5-TiO2/TiO2/Ti (coating codeCu-MTa2O5) was developed by radio frequency (RF) and direct current (DC) reactive magnetron sputtering. Meanwhile, to better display the multilayer Ta2O5 coating mentioned above, a monolayer Ta2O5 ceramic coating was deposited onto the surface of Ti6Al4V alloy as a reference. The surface morphology, microstructure, phase constituents, and elemental states of the coating were evaluated by atomic force microscopy, scanning electron microscopy, X-ray diffraction, and X-ray photoelectron spectroscopy, respectively. The adhesion strength, wettability, anticorrosion and antibacterial properties of the coating were examined by a scratch tester, contact angle measurement, electrochemical workstations, and plate counting method, respectively. The results showed that the deposited coatings were amorphous and hydrophobic. Cu doped into the Ta2O5 coating existed as CuO and Cu2O. A Ta2O5-TiO2/TiO2/Ti multi-interlayer massively enhanced the adhesion strength of the coating, which was 2.9 times stronger than that of the monolayer Ta2O5coating. The multilayer Cu-MTa2O5 coating revealed a higher corrosion potential and smaller corrosion current density as compared to the uncoated Ti6Al4V, indicating the better anticorrosion performance of Ti6Al4V. Moreover, a 99.8% antibacterial effect of Cu-MTa2O5 coated against Staphylococcus aureuswas obtained.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Ding, Z., Wang, Y., Zhou, Q., Ding, Z., Wu, Y., Zhu, Y., Shi, W., & He, Q. (2019). The Preparation and Properties of Multilayer Cu-MTa2O5 Composite Coatings on Ti6Al4V for Biomedical Applications. Nanomaterials, 9(10), 1498. https://doi.org/10.3390/nano9101498
MLA 9
Ding, Zeliang, et al. “The Preparation and Properties of Multilayer Cu-MTa2O5 Composite Coatings on Ti6Al4V for Biomedical Applications.” Nanomaterials, vol. 9, no. 10, 2019, p. 1498. https://doi.org/10.3390/nano9101498.
Chicago
Ding, Zeliang, Yi Wang, Quan Zhou, Ziyu Ding, Yiyong Wu, Yuefang Zhu, Wensong Shi, and Quanguo He. 2019. “The Preparation and Properties of Multilayer Cu-MTa2O5 Composite Coatings on Ti6Al4V for Biomedical Applications.” Nanomaterials 9 (10): 1498. https://doi.org/10.3390/nano9101498.
Harvard
Ding, Z. et al. (2019) ‘The Preparation and Properties of Multilayer Cu-MTa2O5 Composite Coatings on Ti6Al4V for Biomedical Applications’, Nanomaterials, 9(10), p. 1498. doi:10.3390/nano9101498.
IEEE
Z. Ding et al., “The Preparation and Properties of Multilayer Cu-MTa2O5 Composite Coatings on Ti6Al4V for Biomedical Applications,” Nanomaterials, vol. 9, no. 10, p. 1498, 2019, doi: 10.3390/nano9101498.
BibTeX
@article{ding2019preparation,
title = {{The Preparation and Properties of Multilayer Cu-MTa2O5 Composite Coatings on Ti6Al4V for Biomedical Applications}},
author = {Ding, Zeliang and Wang, Yi and Zhou, Quan and Ding, Ziyu and Wu, Yiyong and Zhu, Yuefang and Shi, Wensong and He, Quanguo},
journal = {Nanomaterials},
year = {2019},
volume = {9},
number = {10},
pages = {1498},
doi = {10.3390/nano9101498},
url = {https://doi.org/10.3390/nano9101498}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2019 | 1 | |
| 2020 | 2 | |
| 2021 | 2 | |
| 2022 | 3 | |
| 2023 | 5 | |
| 2024 | 3 | |
| 2026 | 2 |
Its field-weighted citation impact is 0.68: it has been cited 0.68 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
- Ti-6Al-4V
- copper doping
- multilayer composite coatings
- reactive magnetron sputtering
- corrosion protection
- antibacterial coatings
- coating adhesion
- hydrophobic surfaces
Work with this paper
Most-cited papers in Materials Science
- Electric Field Effect in Atomically Thin Carbon FilmsKostya S. Novoselov, Andre K. Geim, Sergey V. Morozov and 5 more · Science · 2004 · 67,474 citations
- Revised effective ionic radii and systematic studies of interatomic distances in halides and chalcogenidesROBERT D. SHANNON · Acta Crystallographica Section A · 1976 · 66,944 citations
- Ab initio molecular dynamics for liquid metalsGeorg Kresse, J. Häfner · Physical review. B, Condensed matter · 1993 · 46,320 citations
- Helical microtubules of graphitic carbonSumio Iijima · Nature · 1991 · 43,639 citations
- The rise of grapheneAndre K. Geim, Kostya S. Novoselov · Nature Materials · 2007 · 40,328 citations
Questions about this paper
How do I cite this paper in APA style?
Ding, Z., Wang, Y., Zhou, Q., Ding, Z., Wu, Y., Zhu, Y., Shi, W., & He, Q. (2019). The Preparation and Properties of Multilayer Cu-MTa2O5 Composite Coatings on Ti6Al4V for Biomedical Applications. Nanomaterials, 9(10), 1498. https://doi.org/10.3390/nano9101498
How many times has this paper been cited?
18 times, according to OpenAlex on 17 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Nanomaterials: sign in and open the PDF from this page.
Who wrote this paper?
Zeliang Ding, Yi Wang, Quan Zhou, Ziyu Ding, Yiyong Wu, Yuefang Zhu, Wensong Shi, Quanguo He.
What is the DOI of this paper?
10.3390/nano9101498, permanently at https://doi.org/10.3390/nano9101498. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 17 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.