Journal article · 2011 · Open access
The Patient Enablement Instrument-French version in a family practice setting: a reliability study
BMC Family Practice, 12(1), 71 · Published 7 July 2011 · DOI 10.1186/1471-2296-12-71
In brief
“The Patient Enablement Instrument-French version in a family practice setting: a reliability study” is a 2011 journal article by Catherine Hudon and 4 co-authors, published in BMC Family Practice. OpenAlex counts 47 citations as of 22 November 2026. It is open access under a CC BY licence: the full text is free to read at BMC Family Practice.
- Citations
- 47
- Most cited in
- 2019 (8)
- Field-weighted impact
- 2.79
- References
- 19
- Authors
- 5
Abstract
BACKGROUND: Patient enablement can be defined as the extent to which a patient is capable of understanding and coping with his or her health issues. This concept is linked to a number of health outcomes such as self-management of chronic diseases and quality of life. The Patient Enablement Instrument (PEI) was designed to measure this concept after a medical consultation. The instrument, in its original form and its translations into several languages, has proven to be reliable and valid. The purpose of this study was to evaluate the reliability of the French version of the PEI (PEI-Fv) in a family practice setting. METHODS: One hundred and ten participants were recruited in a family medicine clinic in the Saguenay region of Quebec (Canada). The PEI-Fv was completed twice, immediately after consultation with a physician (T1) and 2 weeks after the consultation (T2). The internal consistency of the tool was assessed with Cronbach's α and test-retest reliability by intraclass correlation coefficient. RESULTS: The mean score for the PEI-Fv was 5.06 ± 3.97 (95% confidence interval [CI]: 4.30-5.81) at T1 and 4.63 ± 3.90 (95% CI: 3.82-5.44) at T2. Cronbach's α was high at T1 (α1 = 0.93; 95% CI: 0.91-0.95) and T2 (α2 = 0.93; 95% CI: 0.91-0.95). The intraclass correlation coefficient was 0.62 (95% CI: 0.48-0.74), indicating a moderate test-retest reliability. CONCLUSIONS: The internal consistency of the PEI-Fv is excellent. Test-retest reliability was moderate to good. Test-retest reliability should be examined in further studies at a less than 2-week interval to reduce maturation bias. This instrument can be used to measure enablement after consultation in a French-speaking family practice setting.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Hudon, C., Fortin, M., Rossignol, F., Bernier, S., & Poitras, M.-È. (2011). The Patient Enablement Instrument-French version in a family practice setting: a reliability study. BMC Family Practice, 12(1), 71. https://doi.org/10.1186/1471-2296-12-71
MLA 9
Hudon, Catherine, et al. “The Patient Enablement Instrument-French version in a family practice setting: a reliability study.” BMC Family Practice, vol. 12, no. 1, 2011, p. 71. https://doi.org/10.1186/1471-2296-12-71.
Chicago
Hudon, Catherine, Martin Fortin, Francis Rossignol, Susie Bernier, and Marie-Ève Poitras. 2011. “The Patient Enablement Instrument-French version in a family practice setting: a reliability study.” BMC Family Practice 12 (1): 71. https://doi.org/10.1186/1471-2296-12-71.
Harvard
Hudon, C. et al. (2011) ‘The Patient Enablement Instrument-French version in a family practice setting: a reliability study’, BMC Family Practice, 12(1), p. 71. doi:10.1186/1471-2296-12-71.
IEEE
C. Hudon, M. Fortin, F. Rossignol, S. Bernier, and M.-È. Poitras, “The Patient Enablement Instrument-French version in a family practice setting: a reliability study,” BMC Family Practice, vol. 12, no. 1, p. 71, 2011, doi: 10.1186/1471-2296-12-71.
BibTeX
@article{hudon2011patient,
title = {{The Patient Enablement Instrument-French version in a family practice setting: a reliability study}},
author = {Hudon, Catherine and Fortin, Martin and Rossignol, Francis and Bernier, Susie and Poitras, Marie-Ève},
journal = {BMC Family Practice},
year = {2011},
volume = {12},
number = {1},
pages = {71},
doi = {10.1186/1471-2296-12-71},
url = {https://doi.org/10.1186/1471-2296-12-71}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2017 | 4 | |
| 2018 | 2 | |
| 2019 | 8 | |
| 2020 | 7 | |
| 2021 | 3 | |
| 2022 | 4 | |
| 2023 | 3 | |
| 2024 | 1 | |
| 2025 | 2 | |
| 2026 | 1 |
Its field-weighted citation impact is 2.79: it has been cited 2.79 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Health Sciences › Nursing › Research and Theory › Health Education and Validation
- patient enablement
- Patient Enablement Instrument
- French adaptation
- test-retest reliability
- internal consistency
- general practice
- self-management
- chronic disease
Work with this paper
Most-cited papers in Nursing
- Magnesium Replacement Improves the Metabolic Profile in Obese and Pre-Diabetic Patients with Mild-to-Moderate Chronic Kidney Disease: A 3-Month, Randomised, Double-Blind, Placebo-Controlled StudyÖmer Toprak, Hüseyin Kurt, Yasin Sarı and 3 more · Kidney & Blood Pressure Research · 2017 · 29,772 citations
- The “Golden Age” of Probiotics: A Systematic Review and Meta-Analysis of Randomized and Observational Studies in Preterm InfantsElda Dermyshi, Yizhong Wang, Chongbing Yan and 4 more · Neonatology · 2017 · 24,587 citations
- Studies on the quantitative and qualitative characterization of erythrocyte glutathione peroxidase.Donald E. Paglia, William N. Valentine · PubMed · 1967 · 10,901 citations
- Maternal and child undernutrition and overweight in low-income and middle-income countriesRobert E. Black, Cesar Gomes Victora, Susan P. Walker and 8 more · The Lancet · 2013 · 9,505 citations
- The content validity index: Are you sure you know what's being reported? critique and recommendationsDenise F. Polit, Cheryl Tatano Beck · Research in Nursing & Health · 2006 · 8,193 citations
Questions about this paper
How do I cite this paper in APA style?
Hudon, C., Fortin, M., Rossignol, F., Bernier, S., & Poitras, M.-È. (2011). The Patient Enablement Instrument-French version in a family practice setting: a reliability study. BMC Family Practice, 12(1), 71. https://doi.org/10.1186/1471-2296-12-71
How many times has this paper been cited?
47 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at BMC Family Practice: sign in and open the PDF from this page.
Who wrote this paper?
Catherine Hudon, Martin Fortin, Francis Rossignol, Susie Bernier, Marie-Ève Poitras.
What is the DOI of this paper?
10.1186/1471-2296-12-71, permanently at https://doi.org/10.1186/1471-2296-12-71. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.