Journal article · 1995 · Open access

The MTT Tetrazolium Salt Assay Scrutinized: How to Use this Assay Reliably to Measure Metabolie Activity of Cell Cultures in vitro for the Assessment of Growth Characteristics, IC 50 -Values and Cell Survival

Anieta M. Sieuwerts, Jan G.M. Klijn, Harry A. Peters, John A. Foekens

Clinical Chemistry and Laboratory Medicine (CCLM), 33(11), 813–824 · Published 1 January 1995 · DOI 10.1515/cclm.1995.33.11.813

Free PDFView at the publisherCite this paper

In brief

“The MTT Tetrazolium Salt Assay Scrutinized: How to Use this Assay Reliably to Measure Metabolie Activity of Cell Cultures in vitro for the Assessment of Growth Characteristics, IC 50 -Values and Cell Survival” is a 1995 journal article by Anieta M. Sieuwerts and 3 co-authors, published in Clinical Chemistry and Laboratory Medicine (CCLM). OpenAlex counts 215 citations as of 15 November 2026. It is open access: the full text is free to read at Clinical Chemistry and Laboratory Medicine (CCLM).

Citations
215
Most cited in
2019 (13)
Field-weighted impact
6.21
References
21
Authors
4

Abstract

The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazoliumbromide (MTT) assay is widely used for in vitro measurement of the metabolic viability of cell cultures subjected to different culture conditions. This convenient assay, which is based on the ability of viable cells to produce formazan, can be affected significantly by a number of conditions. These conditions can be roughly divided into groups, firstly influences which affect the spectrum of the produced formazan and secondly influences which affect the amount of formazan produced per cell. We studied the various chemical and biochemical aspects involved in the MTT assay. Our data indicated that microscopical viewing of cell cultures before and after performing the assay, a medium renewal with a well-defined MTT-incubation medium at the end of the culture period and regular cell counting are essential steps to ensure a reliable performance of the MTT assay. In conclusion, providing the necessary precautions are taken, the MTT assay can be used reliably to measure metabolic activity of cell cultures in vitro for the assessment of growth characteristics, IC50-values and cell survival.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Sieuwerts, A. M., Klijn, J. G., Peters, H. A., & Foekens, J. A. (1995). The MTT Tetrazolium Salt Assay Scrutinized: How to Use this Assay Reliably to Measure Metabolie Activity of Cell Cultures in vitro for the Assessment of Growth Characteristics, IC 50 -Values and Cell Survival. Clinical Chemistry and Laboratory Medicine (CCLM), 33(11), 813–824. https://doi.org/10.1515/cclm.1995.33.11.813

MLA 9

Sieuwerts, Anieta M., et al. “The MTT Tetrazolium Salt Assay Scrutinized: How to Use this Assay Reliably to Measure Metabolie Activity of Cell Cultures in vitro for the Assessment of Growth Characteristics, IC 50 -Values and Cell Survival.” Clinical Chemistry and Laboratory Medicine (CCLM), vol. 33, no. 11, 1995, pp. 813–824. https://doi.org/10.1515/cclm.1995.33.11.813.

Chicago

Sieuwerts, Anieta M., Jan G.M. Klijn, Harry A. Peters, and John A. Foekens. 1995. “The MTT Tetrazolium Salt Assay Scrutinized: How to Use this Assay Reliably to Measure Metabolie Activity of Cell Cultures in vitro for the Assessment of Growth Characteristics, IC 50 -Values and Cell Survival.” Clinical Chemistry and Laboratory Medicine (CCLM) 33 (11): 813–824. https://doi.org/10.1515/cclm.1995.33.11.813.

Harvard

Sieuwerts, A. M. et al. (1995) ‘The MTT Tetrazolium Salt Assay Scrutinized: How to Use this Assay Reliably to Measure Metabolie Activity of Cell Cultures in vitro for the Assessment of Growth Characteristics, IC 50 -Values and Cell Survival’, Clinical Chemistry and Laboratory Medicine (CCLM), 33(11), pp. 813–824. doi:10.1515/cclm.1995.33.11.813.

IEEE

A. M. Sieuwerts, J. G. Klijn, H. A. Peters, and J. A. Foekens, “The MTT Tetrazolium Salt Assay Scrutinized: How to Use this Assay Reliably to Measure Metabolie Activity of Cell Cultures in vitro for the Assessment of Growth Characteristics, IC 50 -Values and Cell Survival,” Clinical Chemistry and Laboratory Medicine (CCLM), vol. 33, no. 11, pp. 813–824, 1995, doi: 10.1515/cclm.1995.33.11.813.

BibTeX

@article{sieuwerts1995tetrazolium,
  title     = {{The MTT Tetrazolium Salt Assay Scrutinized: How to Use this Assay Reliably to Measure Metabolie Activity of Cell Cultures in vitro for the Assessment of Growth Characteristics, IC 50 -Values and Cell Survival}},
  author    = {Sieuwerts, Anieta M. and Klijn, Jan G.M. and Peters, Harry A. and Foekens, John A.},
  journal   = {Clinical Chemistry and Laboratory Medicine (CCLM)},
  year      = {1995},
  volume    = {33},
  number    = {11},
  pages     = {813--824},
  doi       = {10.1515/cclm.1995.33.11.813},
  url       = {https://doi.org/10.1515/cclm.1995.33.11.813}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
20171010
20181010
20191313
202088
202177
202255
202355
202477
202511
202677

Its field-weighted citation impact is 6.21: it has been cited 6.21 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Veterinary › Small Animals › Animal testing and alternatives

  • MTT assay
  • tetrazolium salts
  • formazan
  • cell metabolic activity
  • cell viability
  • IC50
  • cell survival
  • cell growth

Work with this paper

Most-cited papers in Veterinary

All highly cited Veterinary papers

Questions about this paper

How do I cite this paper in APA style?

Sieuwerts, A. M., Klijn, J. G., Peters, H. A., & Foekens, J. A. (1995). The MTT Tetrazolium Salt Assay Scrutinized: How to Use this Assay Reliably to Measure Metabolie Activity of Cell Cultures in vitro for the Assessment of Growth Characteristics, IC 50 -Values and Cell Survival. Clinical Chemistry and Laboratory Medicine (CCLM), 33(11), 813–824. https://doi.org/10.1515/cclm.1995.33.11.813

How many times has this paper been cited?

215 times, according to OpenAlex on 15 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access: read the free full text at Clinical Chemistry and Laboratory Medicine (CCLM).

Who wrote this paper?

Anieta M. Sieuwerts, Jan G.M. Klijn, Harry A. Peters, John A. Foekens.

What is the DOI of this paper?

10.1515/cclm.1995.33.11.813. The permanent link is https://doi.org/10.1515/cclm.1995.33.11.813.

Bibliographic data from OpenAlex (CC0), last checked 15 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.