Journal article · 2013 · Open access

The Effect of Applied Strain during Repeated Heat-treatment under Constrained Strain on The Mechanical and Shape Memory Properties of Ti-Ni Shape Memory Alloy

H. Cho, Daichi KOTEGAWA, Toshio Sakuma, K. Yamauchi

Transactions of the Materials Research Society of Japan, 38(3), 427–431 · Published 1 January 2013 · DOI 10.14723/tmrsj.38.427

Open PDFView at the publisherCite this paper

In brief

“The Effect of Applied Strain during Repeated Heat-treatment under Constrained Strain on The Mechanical and Shape Memory Properties of Ti-Ni Shape Memory Alloy” is a 2013 journal article by H. Cho and 3 co-authors, published in Transactions of the Materials Research Society of Japan. OpenAlex counts 1 citations as of 22 November 2026. It is open access: the full text is free to read at Transactions of the Materials Research Society of Japan.

Citations
1
Most cited in
2015 (1)
Field-weighted impact
0.12
References
6
Authors
4

Abstract

The repeated heat-treatment under constrained strain is necessary for the manufacturing process of laser-cut Ti-Ni shape memory alloy (SMA) stent. In this research, the effect of applied strain during repeated heat-treatment under constrained strain on the mechanical and shape-memory properties of the Ti-Ni SMA wire was investigated. The chemical composition of the alloy is Ti-50.4at%Ni. At first, the specimen is heat-treated at 673 K for 3.6 ks. And then, heat-treatment under constrained strain, at 773 K for 0.3 ks. The applied strain at a single heat-treatment (εap) was 8 %, 10 % and 13.3 %, and the heat-treatment is repeated so as to achieve a total applied strain of 40 %. The critical stress for inducing martensite (σM) and minimum recovery stress (σmin) increases with increasing εap. However, σM of each specimen becomes constant during amplitude testing. In addition, σmin of εap=8 % and 10 % became 0 MPa during amplitude testing. Meanwhile, the σM of εap=13.3 % does not become 0 MPa during amplitude testing. Thus, the function deterioration is reduced by increasing εap. The reduction of function deterioration is caused by the increase of dislocation density with increasing εap.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Cho, H., KOTEGAWA, D., Sakuma, T., & Yamauchi, K. (2013). The Effect of Applied Strain during Repeated Heat-treatment under Constrained Strain on The Mechanical and Shape Memory Properties of Ti-Ni Shape Memory Alloy. Transactions of the Materials Research Society of Japan, 38(3), 427–431. https://doi.org/10.14723/tmrsj.38.427

MLA 9

Cho, H., et al. “The Effect of Applied Strain during Repeated Heat-treatment under Constrained Strain on The Mechanical and Shape Memory Properties of Ti-Ni Shape Memory Alloy.” Transactions of the Materials Research Society of Japan, vol. 38, no. 3, 2013, pp. 427–431. https://doi.org/10.14723/tmrsj.38.427.

Chicago

Cho, H., Daichi KOTEGAWA, Toshio Sakuma, and K. Yamauchi. 2013. “The Effect of Applied Strain during Repeated Heat-treatment under Constrained Strain on The Mechanical and Shape Memory Properties of Ti-Ni Shape Memory Alloy.” Transactions of the Materials Research Society of Japan 38 (3): 427–431. https://doi.org/10.14723/tmrsj.38.427.

Harvard

Cho, H. et al. (2013) ‘The Effect of Applied Strain during Repeated Heat-treatment under Constrained Strain on The Mechanical and Shape Memory Properties of Ti-Ni Shape Memory Alloy’, Transactions of the Materials Research Society of Japan, 38(3), pp. 427–431. doi:10.14723/tmrsj.38.427.

IEEE

H. Cho, D. KOTEGAWA, T. Sakuma, and K. Yamauchi, “The Effect of Applied Strain during Repeated Heat-treatment under Constrained Strain on The Mechanical and Shape Memory Properties of Ti-Ni Shape Memory Alloy,” Transactions of the Materials Research Society of Japan, vol. 38, no. 3, pp. 427–431, 2013, doi: 10.14723/tmrsj.38.427.

BibTeX

@article{cho2013effect,
  title     = {{The Effect of Applied Strain during Repeated Heat-treatment under Constrained Strain on The Mechanical and Shape Memory Properties of Ti-Ni Shape Memory Alloy}},
  author    = {Cho, H. and KOTEGAWA, Daichi and Sakuma, Toshio and Yamauchi, K.},
  journal   = {Transactions of the Materials Research Society of Japan},
  year      = {2013},
  volume    = {38},
  number    = {3},
  pages     = {427--431},
  doi       = {10.14723/tmrsj.38.427},
  url       = {https://doi.org/10.14723/tmrsj.38.427}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Materials Science › Materials Chemistry › Shape Memory Alloy Transformations

  • TiNi shape memory alloy
  • applied strain
  • martensitic transformation
  • recovery stress
  • dislocation density
  • stent manufacturing
  • mechanical properties

Work with this paper

Most-cited papers in Materials Science

All highly cited Materials Science papers

Questions about this paper

How do I cite this paper in APA style?

Cho, H., KOTEGAWA, D., Sakuma, T., & Yamauchi, K. (2013). The Effect of Applied Strain during Repeated Heat-treatment under Constrained Strain on The Mechanical and Shape Memory Properties of Ti-Ni Shape Memory Alloy. Transactions of the Materials Research Society of Japan, 38(3), 427–431. https://doi.org/10.14723/tmrsj.38.427

How many times has this paper been cited?

1 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Transactions of the Materials Research Society of Japan: sign in and open the PDF from this page.

Who wrote this paper?

H. Cho, Daichi KOTEGAWA, Toshio Sakuma, K. Yamauchi.

What is the DOI of this paper?

10.14723/tmrsj.38.427, permanently at https://doi.org/10.14723/tmrsj.38.427. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.