Journal article · 2021 · Open access

Tensile strength assay comparing the resistance between two different autologous platelet concentrates (leucocyte-platelet rich fibrin versus advanced-platelet rich fibrin): a pilot study

Martim de Almeida Nóbrega Correia Pascoal, N. Santos, António Completo, Gustavo Vicentis Oliveira Fernandes

International Journal of Implant Dentistry, 7(1), 1 · Published 15 January 2021 · DOI 10.1186/s40729-020-00284-w

Open PDFView at the publisherCite this paper

In brief

“Tensile strength assay comparing the resistance between two different autologous platelet concentrates (leucocyte-platelet rich fibrin versus advanced-platelet rich fibrin): a pilot study” is a 2021 journal article by Martim de Almeida Nóbrega Correia Pascoal and 3 co-authors, published in International Journal of Implant Dentistry. OpenAlex counts 28 citations as of 20 November 2026. It is open access under a CC BY licence: the full text is free to read at International Journal of Implant Dentistry.

Citations
28
Most cited in
2025 (11)
Field-weighted impact
1.89
References
36
Authors
4

Abstract

Background Since the leucocyte-platelet rich fibrin (L-PRF) was published in 2001, many studies have been developed, analyzing its properties, and also verifying new possibilities to improve it. Thereby, it emerges the advanced-platelet rich fibrin (A-PRF) with a protocol that optimizes the properties obtained by the L-PRF. Nonetheless, there is a gap in the literature to landmark the evolutive process concerning the mechanical properties in specific the resistance to tensile strength which consequently may influence the time for membrane degradation. Thus, this study had the goal to compare the resistance to the traction of membranes produced with the original L-PRF and A-PRF protocols, being the first to this direct comparison. Findings The harvest of blood from a healthy single person, with no history of anticoagulant usage. We performed the protocols described in the literature, within a total of 13 membranes produced for each protocol ( n = 26). Afterward, the membranes were prepared and submitted to a traction test assessing the maximal and the average traction achieved for each membrane. The data were analyzed statistically using the unpaired t test. Regarding average traction, A-PRF obtained a value of 0.0288 N mm −2 and L-PRF 0.0192 N mm −2 ( p < 0.05 using unpaired t test). For maximal traction, A-PRF obtained 0.0752 N mm −2 and L-PRF 0.0425 N mm −2 ( p < 0.05 using unpaired t test). Conclusion With this study, it was possible to conclude that indeed A-PRF has a significative higher maximal traction score and higher average traction compared to L-PRF, indicating that it had a higher resistance when two opposing forces are applied.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Pascoal, M. D. A. N. C., Santos, N., Completo, A., & Fernandes, G. V. O. (2021). Tensile strength assay comparing the resistance between two different autologous platelet concentrates (leucocyte-platelet rich fibrin versus advanced-platelet rich fibrin): a pilot study. International Journal of Implant Dentistry, 7(1), 1. https://doi.org/10.1186/s40729-020-00284-w

MLA 9

Pascoal, Martim de Almeida Nóbrega Correia, et al. “Tensile strength assay comparing the resistance between two different autologous platelet concentrates (leucocyte-platelet rich fibrin versus advanced-platelet rich fibrin): a pilot study.” International Journal of Implant Dentistry, vol. 7, no. 1, 2021, p. 1. https://doi.org/10.1186/s40729-020-00284-w.

Chicago

Pascoal, Martim de Almeida Nóbrega Correia, N. Santos, António Completo, and Gustavo Vicentis Oliveira Fernandes. 2021. “Tensile strength assay comparing the resistance between two different autologous platelet concentrates (leucocyte-platelet rich fibrin versus advanced-platelet rich fibrin): a pilot study.” International Journal of Implant Dentistry 7 (1): 1. https://doi.org/10.1186/s40729-020-00284-w.

Harvard

Pascoal, M. D. A. N. C. et al. (2021) ‘Tensile strength assay comparing the resistance between two different autologous platelet concentrates (leucocyte-platelet rich fibrin versus advanced-platelet rich fibrin): a pilot study’, International Journal of Implant Dentistry, 7(1), p. 1. doi:10.1186/s40729-020-00284-w.

IEEE

M. D. A. N. C. Pascoal, N. Santos, A. Completo, and G. V. O. Fernandes, “Tensile strength assay comparing the resistance between two different autologous platelet concentrates (leucocyte-platelet rich fibrin versus advanced-platelet rich fibrin): a pilot study,” International Journal of Implant Dentistry, vol. 7, no. 1, p. 1, 2021, doi: 10.1186/s40729-020-00284-w.

BibTeX

@article{pascoal2021tensile,
  title     = {{Tensile strength assay comparing the resistance between two different autologous platelet concentrates (leucocyte-platelet rich fibrin versus advanced-platelet rich fibrin): a pilot study}},
  author    = {Pascoal, Martim de Almeida Nóbrega Correia and Santos, N. and Completo, António and Fernandes, Gustavo Vicentis Oliveira},
  journal   = {International Journal of Implant Dentistry},
  year      = {2021},
  volume    = {7},
  number    = {1},
  pages     = {1},
  doi       = {10.1186/s40729-020-00284-w},
  url       = {https://doi.org/10.1186/s40729-020-00284-w}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
202111
202233
202344
202444
20251111
202655

Its field-weighted citation impact is 1.89: it has been cited 1.89 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Dentistry › Periodontics › Periodontal Regeneration and Treatments

  • advanced platelet-rich fibrin
  • autologous platelet concentrate
  • tensile strength
  • mechanical properties
  • membrane degradation
  • bone graft substitutes
  • guided bone regeneration

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Pascoal, M. D. A. N. C., Santos, N., Completo, A., & Fernandes, G. V. O. (2021). Tensile strength assay comparing the resistance between two different autologous platelet concentrates (leucocyte-platelet rich fibrin versus advanced-platelet rich fibrin): a pilot study. International Journal of Implant Dentistry, 7(1), 1. https://doi.org/10.1186/s40729-020-00284-w

How many times has this paper been cited?

28 times, according to OpenAlex on 20 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at International Journal of Implant Dentistry: sign in and open the PDF from this page.

Who wrote this paper?

Martim de Almeida Nóbrega Correia Pascoal, N. Santos, António Completo, Gustavo Vicentis Oliveira Fernandes.

What is the DOI of this paper?

10.1186/s40729-020-00284-w, permanently at https://doi.org/10.1186/s40729-020-00284-w. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 20 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.