Journal article · 2017
Tailoring the surface of NiTi alloy by TiN coating for biomedical application
Materials Technology, 32(11), 657–667 · Published 1 May 2017 · DOI 10.1080/10667857.2017.1321277
In brief
“Tailoring the surface of NiTi alloy by TiN coating for biomedical application” is a 2017 journal article by Qiang Wang and 4 co-authors, published in Materials Technology. OpenAlex counts 10 citations as of 17 November 2026. The publisher's version is not open access, and OpenAlex records no free legal copy.
- Citations
- 10
- Most cited in
- 2018 (2)
- Field-weighted impact
- 1.01
- References
- 42
- Authors
- 5
Abstract
In this study, TiN coating was produced on nickel titanium (NiTi) alloy using a filtered arcing ion plate technique in order to efficiently avoid the potential hazards of Ni element. The successful formation of TiN coating was showed by X-ray diffractometer and scanning electron microscope coupled with energy-dispersive spectrometer. Microhardness tests with different loading conditions… Read the full abstract at the publisher.
Excerpt. This paper is not open access.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Wang, Q., Zhang, S., Zhang, C., Wu, C., & Sun, Z. (2017). Tailoring the surface of NiTi alloy by TiN coating for biomedical application. Materials Technology, 32(11), 657–667. https://doi.org/10.1080/10667857.2017.1321277
MLA 9
Wang, Qiang, et al. “Tailoring the surface of NiTi alloy by TiN coating for biomedical application.” Materials Technology, vol. 32, no. 11, 2017, pp. 657–667. https://doi.org/10.1080/10667857.2017.1321277.
Chicago
Wang, Qiang, Song Zhang, Chunhua Zhang, Chengliang Wu, and Zulai Sun. 2017. “Tailoring the surface of NiTi alloy by TiN coating for biomedical application.” Materials Technology 32 (11): 657–667. https://doi.org/10.1080/10667857.2017.1321277.
Harvard
Wang, Q. et al. (2017) ‘Tailoring the surface of NiTi alloy by TiN coating for biomedical application’, Materials Technology, 32(11), pp. 657–667. doi:10.1080/10667857.2017.1321277.
IEEE
Q. Wang, S. Zhang, C. Zhang, C. Wu, and Z. Sun, “Tailoring the surface of NiTi alloy by TiN coating for biomedical application,” Materials Technology, vol. 32, no. 11, pp. 657–667, 2017, doi: 10.1080/10667857.2017.1321277.
BibTeX
@article{wang2017tailoring,
title = {{Tailoring the surface of NiTi alloy by TiN coating for biomedical application}},
author = {Wang, Qiang and Zhang, Song and Zhang, Chunhua and Wu, Chengliang and Sun, Zulai},
journal = {Materials Technology},
year = {2017},
volume = {32},
number = {11},
pages = {657--667},
doi = {10.1080/10667857.2017.1321277},
url = {https://doi.org/10.1080/10667857.2017.1321277}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2018 | 2 | |
| 2019 | 1 | |
| 2020 | 2 | |
| 2021 | 1 | |
| 2023 | 2 | |
| 2025 | 1 | |
| 2026 | 1 |
Its field-weighted citation impact is 1.01: it has been cited 1.01 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings
- NiTi
- TiN coating
- surface modification
- corrosion resistance
- wear resistance
- microhardness
- cell growth
- fibroblast viability
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Wang, Q., Zhang, S., Zhang, C., Wu, C., & Sun, Z. (2017). Tailoring the surface of NiTi alloy by TiN coating for biomedical application. Materials Technology, 32(11), 657–667. https://doi.org/10.1080/10667857.2017.1321277
How many times has this paper been cited?
10 times, according to OpenAlex on 17 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.
Who wrote this paper?
Qiang Wang, Song Zhang, Chunhua Zhang, Chengliang Wu, Zulai Sun.
What is the DOI of this paper?
10.1080/10667857.2017.1321277, permanently at https://doi.org/10.1080/10667857.2017.1321277. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 17 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.