Journal article · 2019 · Open access

Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns

Catherine Disney, Alexander Eckersley, James C. McConnell, H. Geng, Andrew J. Bodey, Judith Alison Hoyland, Peter David Lee, Michael J. Sherratt, Brian K. Bay

Acta Biomaterialia, 92, 290–304 · Published 10 May 2019 · DOI 10.1016/j.actbio.2019.05.021

Open PDFView at the publisherCite this paper

In brief

“Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns” is a 2019 journal article by Catherine Disney and 8 co-authors, published in Acta Biomaterialia. OpenAlex counts 83 citations as of 20 November 2026, which puts it in the top 7% of works published in 2019 by citations. It is open access under a CC BY licence: the full text is free to read at Acta Biomaterialia.

Citations
83
Most cited in
2026 (17)
Field-weighted impact
8.96
References
79
Authors
9

Abstract

The intervertebral disc (IVD) has a complex and multiscale extracellular matrix structure which provides unique mechanical properties to withstand physiological loading. Low back pain has been linked to degeneration of the disc but reparative treatments are not currently available. Characterising the disc's 3D microstructure and its response in a physiologically relevant loading environment is required to improve understanding of degeneration and to develop new reparative treatments. In this study, techniques for imaging the native IVD, measuring internal deformation and mapping volumetric strain were applied to an in situ compressed ex vivo rat lumbar spine segment. Synchrotron X-ray micro-tomography (synchrotron CT) was used to resolve IVD structures at microscale resolution. These image data enabled 3D quantification of collagen bundle orientation and measurement of local displacement in the annulus fibrosus between sequential scans using digital volume correlation (DVC). The volumetric strain mapped from synchrotron CT provided a detailed insight into the micromechanics of native IVD tissue. The DVC findings showed that there was no slipping at lamella boundaries, and local strain patterns were of a similar distribution to the previously reported elastic network with some heterogeneous areas and maximum strain direction aligned with bundle orientation, suggesting bundle stretching and sliding. This method has the potential to bridge the gap between measures of macro-mechanical properties and the local 3D micro-mechanical environment experienced by cells. This is the first evaluation of strain at the micro scale level in the intact IVD and provides a quantitative framework for future IVD degeneration mechanics studies and testing of tissue engineered IVD replacements. STATEMENT OF SIGNIFICANCE: Synchrotron in-line phase contrast X-ray tomography provided the first visualisation of native intact intervertebral disc microstructural deformation in 3D. For two annulus fibrosus volumes of interest, collagen bundle orientation was quantified and local displacement mapped as strain. Direct evidence of microstructural influence on strain patterns could be seen such as no slipping at lamellae boundaries and maximum strain direction aligned with collagen bundle orientation. Although disc elastic structures were not directly observed, the strain patterns had a similar distribution to the previously reported elastic network. This study presents technical advances and is a basis for future X-ray microscopy, structural quantification and digital volume correlation strain analysis of soft tissue.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Disney, C., Eckersley, A., McConnell, J. C., Geng, H., Bodey, A. J., Hoyland, J. A., Lee, P. D., Sherratt, M. J., & Bay, B. K. (2019). Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns. Acta Biomaterialia, 92, 290–304. https://doi.org/10.1016/j.actbio.2019.05.021

MLA 9

Disney, Catherine, et al. “Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns.” Acta Biomaterialia, vol. 92, 2019, pp. 290–304. https://doi.org/10.1016/j.actbio.2019.05.021.

Chicago

Disney, Catherine, Alexander Eckersley, James C. McConnell, H. Geng, Andrew J. Bodey, Judith Alison Hoyland, Peter David Lee, Michael J. Sherratt, and Brian K. Bay. 2019. “Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns.” Acta Biomaterialia 92: 290–304. https://doi.org/10.1016/j.actbio.2019.05.021.

Harvard

Disney, C. et al. (2019) ‘Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns’, Acta Biomaterialia, 92, pp. 290–304. doi:10.1016/j.actbio.2019.05.021.

IEEE

C. Disney et al., “Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns,” Acta Biomaterialia, vol. 92, pp. 290–304, 2019, doi: 10.1016/j.actbio.2019.05.021.

BibTeX

@article{disney2019synchrotron,
  title     = {{Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns}},
  author    = {Disney, Catherine and Eckersley, Alexander and McConnell, James C. and Geng, H. and Bodey, Andrew J. and Hoyland, Judith Alison and Lee, Peter David and Sherratt, Michael J. and Bay, Brian K.},
  journal   = {Acta Biomaterialia},
  year      = {2019},
  volume    = {92},
  pages     = {290--304},
  doi       = {10.1016/j.actbio.2019.05.021},
  url       = {https://doi.org/10.1016/j.actbio.2019.05.021}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201922
202088
20211414
20221212
202366
20241010
20251414
20261717

Its field-weighted citation impact is 8.96: it has been cited 8.96 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Medicine › Orthopedics and Sports Medicine › Spine and Intervertebral Disc Pathology

  • intervertebral disc
  • annulus fibrosus
  • volumetric strain
  • lamellar microstructure
  • micromechanics
  • intervertebral disc degeneration
  • low back pain
  • synchrotron X-ray microtomography

Work with this paper

Most-cited papers in Medicine

All highly cited Medicine papers

Questions about this paper

How do I cite this paper in APA style?

Disney, C., Eckersley, A., McConnell, J. C., Geng, H., Bodey, A. J., Hoyland, J. A., Lee, P. D., Sherratt, M. J., & Bay, B. K. (2019). Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns. Acta Biomaterialia, 92, 290–304. https://doi.org/10.1016/j.actbio.2019.05.021

How many times has this paper been cited?

83 times, according to OpenAlex on 20 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Acta Biomaterialia: sign in and open the PDF from this page.

Who wrote this paper?

Catherine Disney, Alexander Eckersley, James C. McConnell, H. Geng, Andrew J. Bodey, Judith Alison Hoyland, Peter David Lee, Michael J. Sherratt, Brian K. Bay.

What is the DOI of this paper?

10.1016/j.actbio.2019.05.021, permanently at https://doi.org/10.1016/j.actbio.2019.05.021. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 20 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.