Journal article · 2000 · Open access
Specimen heating holder for high temperature high resolution transmission electron microscopy and its application.
Japanese Magazine of Mineralogical and Petrological Sciences, 29(4), 150–155 · Published 1 January 2000 · DOI 10.2465/gkk.29.150
In brief
“Specimen heating holder for high temperature high resolution transmission electron microscopy and its application.” is a 2000 journal article by Takeo Kamino and Kishio Hidaka, published in Japanese Magazine of Mineralogical and Petrological Sciences. OpenAlex counts 0 citations as of 16 November 2026. It is open access: the full text is free to read at Japanese Magazine of Mineralogical and Petrological Sciences.
- Citations
- 0
- References
- 7
- Authors
- 2
Abstract
In situ electron microscope observation is a very useful technique to observe directly structural changes of materials. A direct heating type hot stage for use with a high resolution transmission electron microscope has been developed. The hot stage allows high resolution transmission electron microscopy observation at high temperatures above 1000°C. This paper describes the performance of the hot stage and its application to a study of a formation and sintering of SiC crystals at 1500°C. SiC crystal growth during sintering was observed at near atomic resolution.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Kamino, T., & Hidaka, K. (2000). Specimen heating holder for high temperature high resolution transmission electron microscopy and its application. Japanese Magazine of Mineralogical and Petrological Sciences, 29(4), 150–155. https://doi.org/10.2465/gkk.29.150
MLA 9
Kamino, Takeo, and Kishio Hidaka. “Specimen heating holder for high temperature high resolution transmission electron microscopy and its application.” Japanese Magazine of Mineralogical and Petrological Sciences, vol. 29, no. 4, 2000, pp. 150–155. https://doi.org/10.2465/gkk.29.150.
Chicago
Kamino, Takeo and Kishio Hidaka. 2000. “Specimen heating holder for high temperature high resolution transmission electron microscopy and its application.” Japanese Magazine of Mineralogical and Petrological Sciences 29 (4): 150–155. https://doi.org/10.2465/gkk.29.150.
Harvard
Kamino, T. and Hidaka, K. (2000) ‘Specimen heating holder for high temperature high resolution transmission electron microscopy and its application.’, Japanese Magazine of Mineralogical and Petrological Sciences, 29(4), pp. 150–155. doi:10.2465/gkk.29.150.
IEEE
T. Kamino and K. Hidaka, “Specimen heating holder for high temperature high resolution transmission electron microscopy and its application.,” Japanese Magazine of Mineralogical and Petrological Sciences, vol. 29, no. 4, pp. 150–155, 2000, doi: 10.2465/gkk.29.150.
BibTeX
@article{kamino2000specimen,
title = {{Specimen heating holder for high temperature high resolution transmission electron microscopy and its application.}},
author = {Kamino, Takeo and Hidaka, Kishio},
journal = {Japanese Magazine of Mineralogical and Petrological Sciences},
year = {2000},
volume = {29},
number = {4},
pages = {150--155},
doi = {10.2465/gkk.29.150},
url = {https://doi.org/10.2465/gkk.29.150}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Life Sciences › Biochemistry, Genetics and Molecular Biology › Structural Biology › Advanced Electron Microscopy Techniques and Applications
- hot stage
- in situ electron microscopy
- high-resolution TEM
- silicon carbide
- SiC crystal growth
- sintering
Work with this paper
Most-cited papers in Biochemistry, Genetics and Molecular Biology
- PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENTOliver H. Lowry, NiraJ. Rosebrough, A. Lewis Farr and 1 more · Journal of Biological Chemistry · 1951 · 316,470 citations
- A Rapid and Sensitive Method for the Quantitation of Microgram Quantities of Protein Utilizing the Principle of Protein-Dye BindingM Bradford · Analytical Biochemistry · 1976 · 256,780 citations
- Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT MethodKenneth J. Livak, Thomas D. Schmittgen · Methods · 2001 · 184,418 citations
- Molecular Cloning: A Laboratory ManualJoseph Sambrook, Elisabeth Fritsch, Tom Maniatis · UCLA - Biblioteca de Ciencias de la Salud · 1989 · 133,493 citations
- Basic Local Alignment Search ToolStephen F. Altschul, Warren R. Gish, Webb Miller and 2 more · Journal of Molecular Biology · 1990 · 100,529 citations
All highly cited Biochemistry, Genetics and Molecular Biology papers
Questions about this paper
How do I cite this paper in APA style?
Kamino, T., & Hidaka, K. (2000). Specimen heating holder for high temperature high resolution transmission electron microscopy and its application. Japanese Magazine of Mineralogical and Petrological Sciences, 29(4), 150–155. https://doi.org/10.2465/gkk.29.150
How many times has this paper been cited?
0 times, according to OpenAlex on 16 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access: read the free full text at Japanese Magazine of Mineralogical and Petrological Sciences.
Who wrote this paper?
Takeo Kamino, Kishio Hidaka.
What is the DOI of this paper?
10.2465/gkk.29.150. The permanent link is https://doi.org/10.2465/gkk.29.150.
Bibliographic data from OpenAlex (CC0), last checked 16 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.