In brief
“Smart Transfemoral Prosthetic Socket with Motorized Cable‐Driven System” is a 2025 journal article by Linda Paternò and 7 co-authors, published in Advanced Intelligent Systems. OpenAlex counts 4 citations as of 22 November 2026. It is open access under a CC BY licence: the full text is free to read at Advanced Intelligent Systems.
- Citations
- 4
- Most cited in
- 2026 (3)
- Field-weighted impact
- 0.70
- References
- 51
- Authors
- 8
Abstract
Volume fluctuations in residual limbs can significantly affect the fit of prosthetic sockets, causing discomfort and instability when wearing a limb prosthesis. As a result, users must frequently visit prosthetic centers for socket adjustments or replacements, which is time‐consuming and limiting. This study introduces a new transfemoral socket that incorporates a motorized cable‐driven mechanism and a sensorized liner, allowing it to adapt to changes in residual limb volume based on interface pressures. Users can control the socket in both open‐ and closed‐loop modes using a customized mobile application. The socket is able to withstand compressive mechanical loads of up to 900 N and demonstrates effective biomechanical coupling capabilities. A mathematical model guide the design of the system and is experimentally verified. To validate the system, an in vitro residual limb simulator with a hydraulic chamber is utilized, enabling volume adjustments of ±7.5%. In closed‐loop mode, the smart socket effectively adjusts its volume to maintain interface pressure within the target range of 70–80 kPa. This innovative smart socket has the potential to enhance user satisfaction by allowing individuals with lower limb amputations to self‐adjust their sockets as needed, ensuring a proper fit and safe interface pressures on tissues.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Paternò, L., Zaidi, A. Z., Polizzotto, M. G., Dalmiani, S., Helsloot, D., Heikens, S., Gruppioni, E., & Menciassi, A. (2025). Smart Transfemoral Prosthetic Socket with Motorized Cable‐Driven System. Advanced Intelligent Systems, 7(11), 2400995. https://doi.org/10.1002/aisy.202400995
MLA 9
Paternò, Linda, et al. “Smart Transfemoral Prosthetic Socket with Motorized Cable‐Driven System.” Advanced Intelligent Systems, vol. 7, no. 11, 2025, p. 2400995. https://doi.org/10.1002/aisy.202400995.
Chicago
Paternò, Linda, Ahmed Zohaib Zaidi, Maria Grazia Polizzotto, Sofia Dalmiani, Djoeke Helsloot, Sybren Heikens, Emanuele Gruppioni, and Arianna Menciassi. 2025. “Smart Transfemoral Prosthetic Socket with Motorized Cable‐Driven System.” Advanced Intelligent Systems 7 (11): 2400995. https://doi.org/10.1002/aisy.202400995.
Harvard
Paternò, L. et al. (2025) ‘Smart Transfemoral Prosthetic Socket with Motorized Cable‐Driven System’, Advanced Intelligent Systems, 7(11), p. 2400995. doi:10.1002/aisy.202400995.
IEEE
L. Paternò et al., “Smart Transfemoral Prosthetic Socket with Motorized Cable‐Driven System,” Advanced Intelligent Systems, vol. 7, no. 11, p. 2400995, 2025, doi: 10.1002/aisy.202400995.
BibTeX
@article{paterno2025smart,
title = {{Smart Transfemoral Prosthetic Socket with Motorized Cable‐Driven System}},
author = {Paternò, Linda and Zaidi, Ahmed Zohaib and Polizzotto, Maria Grazia and Dalmiani, Sofia and Helsloot, Djoeke and Heikens, Sybren and Gruppioni, Emanuele and Menciassi, Arianna},
journal = {Advanced Intelligent Systems},
year = {2025},
volume = {7},
number = {11},
pages = {2400995},
doi = {10.1002/aisy.202400995},
url = {https://doi.org/10.1002/aisy.202400995}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- transfemoral prosthesis
- cable-driven mechanism
- interface pressure
- feedback control
- mobile app control
- lower limb amputation
- socket fit
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Paternò, L., Zaidi, A. Z., Polizzotto, M. G., Dalmiani, S., Helsloot, D., Heikens, S., Gruppioni, E., & Menciassi, A. (2025). Smart Transfemoral Prosthetic Socket with Motorized Cable‐Driven System. Advanced Intelligent Systems, 7(11), 2400995. https://doi.org/10.1002/aisy.202400995
How many times has this paper been cited?
4 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Advanced Intelligent Systems: sign in and open the PDF from this page.
Who wrote this paper?
Linda Paternò, Ahmed Zohaib Zaidi, Maria Grazia Polizzotto, Sofia Dalmiani, Djoeke Helsloot, Sybren Heikens, Emanuele Gruppioni, Arianna Menciassi.
What is the DOI of this paper?
10.1002/aisy.202400995, permanently at https://doi.org/10.1002/aisy.202400995. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.