Paper · 2018 · Open access
Smart sockets for lower limb prostheses
Published 1 November 2018 · DOI 10.25560/78771
In brief
“Smart sockets for lower limb prostheses” is a 2018 paper by Matthew Hopkins. OpenAlex counts 3 citations as of 22 November 2026. It is open access: the full text is free to read at Imperial College Research Computing Service Data Repository.
- Citations
- 3
- Most cited in
- 2021 (1)
- Field-weighted impact
- 0.08
- Authors
- 1
Abstract
Major limb amputation affects up to five-thousand people a year in England alone, with recent conflicts in Afghanistan and Iraq often contributing individuals with complex amputations to the affected population. Despite considerable advances in technology of lower limb prosthetic legs, the socket interface between the residual limb and prostheses has remained largely unchanged. Amputees with poor fitting sockets can endure loading through pressure intolerant portions of their residual limb, introducing discomfort. Continued high pressures, shear stresses and the build-up of heat can lead to the development of numerous conditions such as pressure sores, stump oedema and skin carcinoma. The onset of such conditions can significantly impact use of the prosthetic limb and lead to reliance on a wheelchairs or crutches. Prosthetists aim to control issues such as excessive localised loading and shear stress through alteration of the socket design, however, there is limited information on suitable thresholds for prevention of tissue damage. Prosthetists must rely on their own judgement, experience and notoriously unreliable verbal feedback from prosthetic limb users. The focus of this thesis is the development of an in-socket pressure measurement system or ‘smart-socket’, to provide prosthetists with a mechanism for improved socket design and avoid the onset of conditions such as pressure sores. A secondary aim of the research was to deliver a portable and unobtrusive system to allow for data collection outside of laboratory or clinical environments, with the potential to provide a long-term monitoring solution. Device hardware consisted of low-cost, low-profile piezoresistive pressure sensors, developed in conjunction with printed circuit boards responsible for data sampling and transfer. A network of up to 144 piezoresistive pressure sensors is used to transduce local loads in combination with a 9 degree of freedom inertial measurement unit mounted on the socket. Readings may be transferred via Bluetooth for real-time measurement or stored on an SD-card. Accompanying software including phone and Windows applications were developed for the purposes of receiving, processing and logging data. System performance was explored using mechanical tests within the range of 0-400kPa. The sensors exhibit a non-linear output with an approximate resolution of 10kPa and a minimal drift of 0.026 Volts per minute. The proposed system’s suitability for application to a clinical environment was examined using an NHS cohort study in which participants had the sensors embedded within their prosthetic sockets. A series of tasks were undertaken to mimic common everyday activities such as ambulation and stair ascent whilst under optical motion-tracking. The results of the research demonstrated an ability to map the inner socket pressure profile…
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Hopkins, M. (2018). Smart sockets for lower limb prostheses. https://doi.org/10.25560/78771
MLA 9
Hopkins, Matthew. “Smart sockets for lower limb prostheses.” 2018. https://doi.org/10.25560/78771.
Chicago
Hopkins, Matthew. 2018. “Smart sockets for lower limb prostheses.” https://doi.org/10.25560/78771.
Harvard
Hopkins, M. (2018) ‘Smart sockets for lower limb prostheses’. doi:10.25560/78771.
IEEE
M. Hopkins, “Smart sockets for lower limb prostheses,” 2018, doi: 10.25560/78771.
BibTeX
@article{hopkins2018smart,
title = {{Smart sockets for lower limb prostheses}},
author = {Hopkins, Matthew},
year = {2018},
doi = {10.25560/78771},
url = {https://doi.org/10.25560/78771}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2021 | 1 | |
| 2022 | 1 | |
| 2023 | 1 |
Its field-weighted citation impact is 0.08: it has been cited 0.08 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- smart socket
- lower limb prosthesis
- piezoresistive pressure sensor
- pressure sore prevention
- shear stress
- inertial measurement unit
- gait phase detection
- real-time pressure monitoring
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Hopkins, M. (2018). Smart sockets for lower limb prostheses. https://doi.org/10.25560/78771
How many times has this paper been cited?
3 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Imperial College Research Computing Service Data Repository: sign in and open the PDF from this page.
Who wrote this paper?
Matthew Hopkins.
What is the DOI of this paper?
10.25560/78771, permanently at https://doi.org/10.25560/78771. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.