Journal article · 2005 · Open access

Shape Memory Alloy Actuator for Artificial Muscle (Proposition of Rolled Film Tube Method)

Toshiya Ishikawa, Takeshi Nakada

TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C, 71(703), 944–950 · Published 1 January 2005 · DOI 10.1299/kikaic.71.944

Open PDFView at the publisherCite this paper

In brief

“Shape Memory Alloy Actuator for Artificial Muscle (Proposition of Rolled Film Tube Method)” is a 2005 journal article by Toshiya Ishikawa and Takeshi Nakada, published in TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C. OpenAlex counts 4 citations as of 22 November 2026. It is open access: the full text is free to read at TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C.

Citations
4
Most cited in
2016 (1)
Field-weighted impact
0.17
Authors
2

Abstract

The inner skeletal humanoid robot needs the actuator with the high performance such as a natural muscle. In this study, we aim to realize the actuator that is comparable with a natural muscle from the viewpoint of flexibility, power and response. We constructed a Shape Memory Alloy (SMA) actuator protected by “Rolled film tube” made of polyimide film with high heat resistance. The SMA actuator proposed in this study is driven by Pulse Frequency Modulation (PFM) found in the bio-motion. As the fundamental characteristic of the actuator, the output force and output displacement against input pulse frequency are investigated in the experiment. Consequently, it is found that the SMA actuator proposed can be employed in place of a natural muscle.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Ishikawa, T., & Nakada, T. (2005). Shape Memory Alloy Actuator for Artificial Muscle (Proposition of Rolled Film Tube Method). TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C, 71(703), 944–950. https://doi.org/10.1299/kikaic.71.944

MLA 9

Ishikawa, Toshiya, and Takeshi Nakada. “Shape Memory Alloy Actuator for Artificial Muscle (Proposition of Rolled Film Tube Method).” TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C, vol. 71, no. 703, 2005, pp. 944–950. https://doi.org/10.1299/kikaic.71.944.

Chicago

Ishikawa, Toshiya and Takeshi Nakada. 2005. “Shape Memory Alloy Actuator for Artificial Muscle (Proposition of Rolled Film Tube Method).” TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C 71 (703): 944–950. https://doi.org/10.1299/kikaic.71.944.

Harvard

Ishikawa, T. and Nakada, T. (2005) ‘Shape Memory Alloy Actuator for Artificial Muscle (Proposition of Rolled Film Tube Method)’, TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C, 71(703), pp. 944–950. doi:10.1299/kikaic.71.944.

IEEE

T. Ishikawa and T. Nakada, “Shape Memory Alloy Actuator for Artificial Muscle (Proposition of Rolled Film Tube Method),” TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C, vol. 71, no. 703, pp. 944–950, 2005, doi: 10.1299/kikaic.71.944.

BibTeX

@article{ishikawa2005shape,
  title     = {{Shape Memory Alloy Actuator for Artificial Muscle (Proposition of Rolled Film Tube Method)}},
  author    = {Ishikawa, Toshiya and Nakada, Takeshi},
  journal   = {TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C},
  year      = {2005},
  volume    = {71},
  number    = {703},
  pages     = {944--950},
  doi       = {10.1299/kikaic.71.944},
  url       = {https://doi.org/10.1299/kikaic.71.944}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Materials Science › Materials Chemistry › Shape Memory Alloy Transformations

  • shape memory alloy actuators
  • artificial muscles
  • polyimide films
  • pulse frequency modulation

Work with this paper

Most-cited papers in Materials Science

All highly cited Materials Science papers

Questions about this paper

How do I cite this paper in APA style?

Ishikawa, T., & Nakada, T. (2005). Shape Memory Alloy Actuator for Artificial Muscle (Proposition of Rolled Film Tube Method). TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C, 71(703), 944–950. https://doi.org/10.1299/kikaic.71.944

How many times has this paper been cited?

4 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C: sign in and open the PDF from this page.

Who wrote this paper?

Toshiya Ishikawa, Takeshi Nakada.

What is the DOI of this paper?

10.1299/kikaic.71.944, permanently at https://doi.org/10.1299/kikaic.71.944. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.