Journal article · 2015
Shape Deposition Manufacturing of a Soft, Atraumatic, and Deployable Surgical Grasper
Journal of Mechanisms and Robotics, 7(2), 021006 · Published 7 January 2015 · DOI 10.1115/1.4029493
In brief
“Shape Deposition Manufacturing of a Soft, Atraumatic, and Deployable Surgical Grasper” is a 2015 journal article by Joshua B. Gafford and 7 co-authors, published in Journal of Mechanisms and Robotics. OpenAlex counts 53 citations as of 22 November 2026. The publisher's version is not open access, and OpenAlex records no free legal copy.
- Citations
- 53
- Most cited in
- 2020 (9)
- Field-weighted impact
- 1.49
- References
- 18
- Authors
- 8
Abstract
This paper details the design, analysis, fabrication, and validation of a deployable, atraumatic grasper intended for retraction and manipulation tasks in manual and robotic minimally invasive surgical (MIS) procedures. Fabricated using a combination of shape deposition manufacturing (SDM) and 3D printing, the device (which acts as a deployable end-effector for robotic platforms) has the potential… Read the full abstract at the publisher.
Excerpt. This paper is not open access.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Gafford, J. B., Ding, Y., Harris, A., McKenna, T., Polygerinos, P., Holland, D., Walsh, C. J., & Moser, A. J. (2015). Shape Deposition Manufacturing of a Soft, Atraumatic, and Deployable Surgical Grasper. Journal of Mechanisms and Robotics, 7(2), 021006. https://doi.org/10.1115/1.4029493
MLA 9
Gafford, Joshua B., et al. “Shape Deposition Manufacturing of a Soft, Atraumatic, and Deployable Surgical Grasper.” Journal of Mechanisms and Robotics, vol. 7, no. 2, 2015, p. 021006. https://doi.org/10.1115/1.4029493.
Chicago
Gafford, Joshua B., Ye Ding, Andrew Harris, Terrence McKenna, Panagiotis Polygerinos, Dónal Holland, Conor J. Walsh, and Arthur James Moser. 2015. “Shape Deposition Manufacturing of a Soft, Atraumatic, and Deployable Surgical Grasper.” Journal of Mechanisms and Robotics 7 (2): 021006. https://doi.org/10.1115/1.4029493.
Harvard
Gafford, J. B. et al. (2015) ‘Shape Deposition Manufacturing of a Soft, Atraumatic, and Deployable Surgical Grasper’, Journal of Mechanisms and Robotics, 7(2), p. 021006. doi:10.1115/1.4029493.
IEEE
J. B. Gafford et al., “Shape Deposition Manufacturing of a Soft, Atraumatic, and Deployable Surgical Grasper,” Journal of Mechanisms and Robotics, vol. 7, no. 2, p. 021006, 2015, doi: 10.1115/1.4029493.
BibTeX
@article{gafford2015shape,
title = {{Shape Deposition Manufacturing of a Soft, Atraumatic, and Deployable Surgical Grasper}},
author = {Gafford, Joshua B. and Ding, Ye and Harris, Andrew and McKenna, Terrence and Polygerinos, Panagiotis and Holland, Dónal and Walsh, Conor J. and Moser, Arthur James},
journal = {Journal of Mechanisms and Robotics},
year = {2015},
volume = {7},
number = {2},
pages = {021006},
doi = {10.1115/1.4029493},
url = {https://doi.org/10.1115/1.4029493}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2017 | 4 | |
| 2018 | 7 | |
| 2019 | 3 | |
| 2020 | 9 | |
| 2021 | 9 | |
| 2022 | 5 | |
| 2023 | 1 | |
| 2024 | 6 | |
| 2025 | 4 | |
| 2026 | 4 |
Its field-weighted citation impact is 1.49: it has been cited 1.49 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- shape deposition manufacturing
- minimally invasive surgery
- robot end-effector
- gear ratio
- pressure sensors
- tissue retraction
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Gafford, J. B., Ding, Y., Harris, A., McKenna, T., Polygerinos, P., Holland, D., Walsh, C. J., & Moser, A. J. (2015). Shape Deposition Manufacturing of a Soft, Atraumatic, and Deployable Surgical Grasper. Journal of Mechanisms and Robotics, 7(2), 021006. https://doi.org/10.1115/1.4029493
How many times has this paper been cited?
53 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.
Who wrote this paper?
Joshua B. Gafford, Ye Ding, Andrew Harris, Terrence McKenna, Panagiotis Polygerinos, Dónal Holland, Conor J. Walsh, Arthur James Moser.
What is the DOI of this paper?
10.1115/1.4029493, permanently at https://doi.org/10.1115/1.4029493. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.