Journal article · 2012 · Open access

Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin

Christian Antfolk, Anders Björkman, S Frank, Fredrik Sebelius, Göran Lundborg, Birgitta Rosén

Journal of Rehabilitation Medicine, 44(8), 702–707 · Published 1 July 2012 · DOI 10.2340/16501977-1001

Open full textCite this paper

In brief

“Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin” is a 2012 journal article by Christian Antfolk and 5 co-authors, published in Journal of Rehabilitation Medicine. OpenAlex counts 141 citations as of 22 November 2026, which puts it in the top 4% of works published in 2012 by citations. It is open access: the full text is free to read at Journal of Rehabilitation Medicine.

Citations
141
Most cited in
2023 (20)
Field-weighted impact
3.48
References
32
Authors
6

Abstract

OBJECTIVE: Lack of sensory feedback is a drawback in today's hand prostheses. We present here a non-invasive simple sensory feedback system, which provides the user of a prosthetic hand with sensory feedback on the arm stump. It is mediated by air in a closed loop system connecting silicone pads on the prosthetic hand with pads on the amputation stump. The silicone pads in a "tactile display" on the amputation stump expand when their corresponding sensor-bulb in the prosthesis is touched, evoking an experience of "real touch". METHODS: Twelve trans-radial amputees and 20 healthy non-amputees participated in the study. We investigated the capacity of the system to mediate detection of touch, discrimination between different levels of pressure and, on the amputees also, the ability to locate touch. RESULTS: The results showed a median touch threshold of 80 and 60 g in amputees and non-amputees, respectively, and 90% and 80% correct answers, respectively, in discrimination between 2 levels of pressure. The amputees located touch (3 sites) correctly in 96% of trials. CONCLUSION: This simple sensory feedback system has the potential to restore sensory feedback in hand amputees and thus it could be a useful tool to enhance prosthesis use.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Antfolk, C., Björkman, A., Frank, S., Sebelius, F., Lundborg, G., & Rosén, B. (2012). Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin. Journal of Rehabilitation Medicine, 44(8), 702–707. https://doi.org/10.2340/16501977-1001

MLA 9

Antfolk, Christian, et al. “Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin.” Journal of Rehabilitation Medicine, vol. 44, no. 8, 2012, pp. 702–707. https://doi.org/10.2340/16501977-1001.

Chicago

Antfolk, Christian, Anders Björkman, S Frank, Fredrik Sebelius, Göran Lundborg, and Birgitta Rosén. 2012. “Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin.” Journal of Rehabilitation Medicine 44 (8): 702–707. https://doi.org/10.2340/16501977-1001.

Harvard

Antfolk, C. et al. (2012) ‘Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin’, Journal of Rehabilitation Medicine, 44(8), pp. 702–707. doi:10.2340/16501977-1001.

IEEE

C. Antfolk, A. Björkman, S. Frank, F. Sebelius, G. Lundborg, and B. Rosén, “Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin,” Journal of Rehabilitation Medicine, vol. 44, no. 8, pp. 702–707, 2012, doi: 10.2340/16501977-1001.

BibTeX

@article{antfolk2012sensory,
  title     = {{Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin}},
  author    = {Antfolk, Christian and Björkman, Anders and Frank, S and Sebelius, Fredrik and Lundborg, Göran and Rosén, Birgitta},
  journal   = {Journal of Rehabilitation Medicine},
  year      = {2012},
  volume    = {44},
  number    = {8},
  pages     = {702--707},
  doi       = {10.2340/16501977-1001},
  url       = {https://doi.org/10.2340/16501977-1001}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201755
20181515
20191515
20201515
202188
202266
20232020
20241212
202588
202644

Its field-weighted citation impact is 3.48: it has been cited 3.48 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics

  • prosthetic hand
  • sensory feedback
  • tactile display
  • transradial amputation
  • amputation stump
  • touch localization

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Antfolk, C., Björkman, A., Frank, S., Sebelius, F., Lundborg, G., & Rosén, B. (2012). Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin. Journal of Rehabilitation Medicine, 44(8), 702–707. https://doi.org/10.2340/16501977-1001

How many times has this paper been cited?

141 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Journal of Rehabilitation Medicine: sign in and open the full text from this page.

Who wrote this paper?

Christian Antfolk, Anders Björkman, S Frank, Fredrik Sebelius, Göran Lundborg, Birgitta Rosén.

What is the DOI of this paper?

10.2340/16501977-1001, permanently at https://doi.org/10.2340/16501977-1001. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.