Review article · 2026 · Open access

Robotic computer-assisted implant surgery: a systematic review and meta-analysis of positional accuracy and clinical implications

Soo-Yeon Yoo, Ji‐Man Park, Zhiyan Piao, Seong‐Kyun Kim, Jai‐Young Koak, Kwang‐Suk Seo, Adriana da Fonte Porto Carreiro, Feng Liu

Dentistry Review, 6(2), 100424 · Published 19 May 2026 · DOI 10.1016/j.dentre.2026.100424

Open full textCite this paper

In brief

“Robotic computer-assisted implant surgery: a systematic review and meta-analysis of positional accuracy and clinical implications” is a 2026 review article by Soo-Yeon Yoo and 7 co-authors, published in Dentistry Review. OpenAlex counts 1 citations as of 18 November 2026, which puts it in the top 9% of works published in 2026 by citations. It is open access under a CC BY licence: the full text is free to read at Dentistry Review.

Citations
1
Most cited in
2026 (1)
Field-weighted impact
1.10
References
68
Authors
8

Abstract

Transferring a digital implant plan accurately to the surgical field remains a persistent limitation in implant dentistry. Static computer-assisted implant surgery (static CAIS) improves plan transfer but provides limited intraoperative correction, and the clinical accuracy of robotic computer-assisted implant surgery (robotic CAIS) has not been comprehensively synthesized. To evaluate the positional accuracy of robotic CAIS and compare it with freehand implant placement and static CAIS. A PRISMA 2020-compliant systematic review and meta-analysis was conducted using PubMed, Embase, Scopus, and Web of Science from inception to December 2025. Eligible in vitro and in vivo studies reporting positional deviations (angular, coronal, and/or apical) between planned and placed implant positions were included. Separate single-arm and comparative meta-analyses were performed using random-effects models. Heterogeneity was assessed using the I² statistic. Reporting bias and potential small-study effects were evaluated through visual inspection of funnel plots. Risk of bias was assessed using ROB 2, ROBINS-I, and QUIN tools. In vitro studies showed low angular and linear deviations under controlled conditions. In clinical studies, pooled angular deviation was approximately 1–2°, with submillimeter coronal and apical deviations. Compared with freehand placement, robotic CAIS reduced angular and linear deviations, with an approximate 5° reduction in angular error and about 1 mm reduction in apical deviation. Comparisons with static CAIS showed smaller but consistent reductions in positional deviations across in vitro and clinical analyses, although the magnitude of difference was more limited. Robotic CAIS improves implant positioning accuracy compared with freehand placement and provides modest advantages over static CAIS. However, evidence regarding long-term clinical outcomes remains limited.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Yoo, S.-Y., Park, J., Piao, Z., Kim, S., Koak, J., Seo, K., Carreiro, A. D. F. P., & Liu, F. (2026). Robotic computer-assisted implant surgery: a systematic review and meta-analysis of positional accuracy and clinical implications. Dentistry Review, 6(2), 100424. https://doi.org/10.1016/j.dentre.2026.100424

MLA 9

Yoo, Soo-Yeon, et al. “Robotic computer-assisted implant surgery: a systematic review and meta-analysis of positional accuracy and clinical implications.” Dentistry Review, vol. 6, no. 2, 2026, p. 100424. https://doi.org/10.1016/j.dentre.2026.100424.

Chicago

Yoo, Soo-Yeon, Ji‐Man Park, Zhiyan Piao, Seong‐Kyun Kim, Jai‐Young Koak, Kwang‐Suk Seo, Adriana da Fonte Porto Carreiro, and Feng Liu. 2026. “Robotic computer-assisted implant surgery: a systematic review and meta-analysis of positional accuracy and clinical implications.” Dentistry Review 6 (2): 100424. https://doi.org/10.1016/j.dentre.2026.100424.

Harvard

Yoo, S.-Y. et al. (2026) ‘Robotic computer-assisted implant surgery: a systematic review and meta-analysis of positional accuracy and clinical implications’, Dentistry Review, 6(2), p. 100424. doi:10.1016/j.dentre.2026.100424.

IEEE

S.-Y. Yoo et al., “Robotic computer-assisted implant surgery: a systematic review and meta-analysis of positional accuracy and clinical implications,” Dentistry Review, vol. 6, no. 2, p. 100424, 2026, doi: 10.1016/j.dentre.2026.100424.

BibTeX

@article{yoo2026robotic,
  title     = {{Robotic computer-assisted implant surgery: a systematic review and meta-analysis of positional accuracy and clinical implications}},
  author    = {Yoo, Soo-Yeon and Park, Ji‐Man and Piao, Zhiyan and Kim, Seong‐Kyun and Koak, Jai‐Young and Seo, Kwang‐Suk and Carreiro, Adriana da Fonte Porto and Liu, Feng},
  journal   = {Dentistry Review},
  year      = {2026},
  volume    = {6},
  number    = {2},
  pages     = {100424},
  doi       = {10.1016/j.dentre.2026.100424},
  url       = {https://doi.org/10.1016/j.dentre.2026.100424}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes

  • dental implant surgery
  • positional accuracy
  • angular deviation
  • coronal deviation
  • apical deviation
  • freehand implant placement
  • digital implant planning

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Yoo, S.-Y., Park, J., Piao, Z., Kim, S., Koak, J., Seo, K., Carreiro, A. D. F. P., & Liu, F. (2026). Robotic computer-assisted implant surgery: a systematic review and meta-analysis of positional accuracy and clinical implications. Dentistry Review, 6(2), 100424. https://doi.org/10.1016/j.dentre.2026.100424

How many times has this paper been cited?

1 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Dentistry Review: sign in and open the full text from this page.

Who wrote this paper?

Soo-Yeon Yoo, Ji‐Man Park, Zhiyan Piao, Seong‐Kyun Kim, Jai‐Young Koak, Kwang‐Suk Seo, Adriana da Fonte Porto Carreiro, Feng Liu.

What is the DOI of this paper?

10.1016/j.dentre.2026.100424, permanently at https://doi.org/10.1016/j.dentre.2026.100424. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.