“Robot-assisted surgery for dental implant placement: A narrative review” is a 2024 review article by MiaoZhen Wang and 3 co-authors, published in Journal of Dentistry. OpenAlex counts 40 citations as of 18 November 2026, which puts it in the top 6% of works published in 2024 by citations. It is open access under a CC BY-NC licence: the full text is free to read at Journal of Dentistry.
- Citations
- 40
- Most cited in
- 2025 (20)
- Field-weighted impact
- 2.31
- References
- 68
- Authors
- 4
Abstract
OBJECTIVE: To determine the current status and accuracy of robotic computer-assisted implant surgery (CAIS) applications by examining the associated clinical and experimental outcomes. DATA AND SOURCES: PubMed, Medline, and Cochrane Library databases were searched for relevant studies published between January 2000 and November 2023, and focusing on robotic CAIS in dental implant surgery. All search results were then manually reviewed to identify only the pertinent articles. Only in vitro and clinical studies were included in this narrative review, with implant placement accuracy considered the main outcome. RESULT: Based on our inclusion and exclusion criteria, we included 21 studies (with 1085 implant sites); of them, 8 were clinical studies, 12 were in vitro studies, and 1 included both an in vitro study and a case series. The ranges of the mean implant shoulder, apical, and angular deviations were respectively 0.43-1.04 mm, 0.53-1.06 mm, and 0.77°-3.77° in the clinical studies and 0.23-1.04 mm, 0.24-2.13 mm, and 0.43°-3.78° in the in vitro studies, respectively. CONCLUSION: The accuracy of robotic CAIS in dental implant procedures appears to be within the clinically acceptable ranges. However, further relevant clinical trials validating the existing evidence are needed. CLINICAL SIGNIFICANCE: Robotic CAIS can achieve clinically acceptable implant placement accuracy. This innovative technology may improve the precision and success rates of dental implant procedures, with benefit for surgeons and patients.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Wang, M., Liu, F., Zhao, X., & Wu, Y. (2024). Robot-assisted surgery for dental implant placement: A narrative review. Journal of Dentistry, 146, 105034. https://doi.org/10.1016/j.jdent.2024.105034
MLA 9
Wang, MiaoZhen, et al. “Robot-assisted surgery for dental implant placement: A narrative review.” Journal of Dentistry, vol. 146, 2024, p. 105034. https://doi.org/10.1016/j.jdent.2024.105034.
Chicago
Wang, MiaoZhen, Feng Liu, Xu Zhao, and Yuwei Wu. 2024. “Robot-assisted surgery for dental implant placement: A narrative review.” Journal of Dentistry 146: 105034. https://doi.org/10.1016/j.jdent.2024.105034.
Harvard
Wang, M. et al. (2024) ‘Robot-assisted surgery for dental implant placement: A narrative review’, Journal of Dentistry, 146, p. 105034. doi:10.1016/j.jdent.2024.105034.
IEEE
M. Wang, F. Liu, X. Zhao, and Y. Wu, “Robot-assisted surgery for dental implant placement: A narrative review,” Journal of Dentistry, vol. 146, p. 105034, 2024, doi: 10.1016/j.jdent.2024.105034.
BibTeX
@article{wang2024robot,
title = {{Robot-assisted surgery for dental implant placement: A narrative review}},
author = {Wang, MiaoZhen and Liu, Feng and Zhao, Xu and Wu, Yuwei},
journal = {Journal of Dentistry},
year = {2024},
volume = {146},
pages = {105034},
doi = {10.1016/j.jdent.2024.105034},
url = {https://doi.org/10.1016/j.jdent.2024.105034}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2024 | 3 | |
| 2025 | 20 | |
| 2026 | 17 |
Its field-weighted citation impact is 2.31: it has been cited 2.31 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- robotic surgery
- computer-assisted implant surgery
- dental implant surgery
- implant placement accuracy
- apical deviation
- clinical outcomes
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Wang, M., Liu, F., Zhao, X., & Wu, Y. (2024). Robot-assisted surgery for dental implant placement: A narrative review. Journal of Dentistry, 146, 105034. https://doi.org/10.1016/j.jdent.2024.105034
How many times has this paper been cited?
40 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Journal of Dentistry: sign in and open the full text from this page.
Who wrote this paper?
MiaoZhen Wang, Feng Liu, Xu Zhao, Yuwei Wu.
What is the DOI of this paper?
10.1016/j.jdent.2024.105034, permanently at https://doi.org/10.1016/j.jdent.2024.105034. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.