Journal article · 2016 · Open access

Reversible Actuation Micro Gripper with Thick SMA Film for Bio-sheet Handing

Ryo Sato, Takahiro Kamada, Takashi Mineta

IEEJ Transactions on Sensors and Micromachines, 136(10), 454–459 · Published 1 January 2016 · DOI 10.1541/ieejsmas.136.454

Open PDFView at the publisherCite this paper

In brief

“Reversible Actuation Micro Gripper with Thick SMA Film for Bio-sheet Handing” is a 2016 journal article by Ryo Sato and 2 co-authors, published in IEEJ Transactions on Sensors and Micromachines. OpenAlex counts 2 citations as of 22 November 2026. It is open access: the full text is free to read at IEEJ Transactions on Sensors and Micromachines.

Citations
2
Most cited in
2018 (1)
Field-weighted impact
0.12
References
11
Authors
3

Abstract

A micro-gripper of reversible operation mechanism was designed and fabricated from a flash-evaporated SMA film of 30 µm in thickness. Thin film Pt heaters, strain gauges, and Pt-Au thermo-couple circuits were integrated on the SMA gripper. The gripper is closed at low temperature because both outer and inner arms of the gripper were similarly deflected due to intrinsic film stress. The gripper has a mechanism to be opened by the outer arm heating for flat shape recovery. The deflection propertied of the SMA gripper was evaluated. The outer arm of the gripper was reversibly deformed to 15 µm or larger when it was heated in water. The gripper was not opened enough for gripping thick bio-films because the temperature of the SMA outer arm was not reached to the peak deformation temperature of the SMA film (~60oC). The inner arm was also deformed to several microns due to the thermal conduction from the heated outer arm. In air operation, the heated outer arm and non-heated inner arm were deformed to 45 µm and 15 µm, respectively. The outer arm was heated to 300oC which was too high to use for bio-film handling. Spring constants of the inner arm were measured as 29.4 N/m which corresponds to a gripping force of 1.6 mN when a 50 µm thick sheet is held by the gripper.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Sato, R., Kamada, T., & Mineta, T. (2016). Reversible Actuation Micro Gripper with Thick SMA Film for Bio-sheet Handing. IEEJ Transactions on Sensors and Micromachines, 136(10), 454–459. https://doi.org/10.1541/ieejsmas.136.454

MLA 9

Sato, Ryo, et al. “Reversible Actuation Micro Gripper with Thick SMA Film for Bio-sheet Handing.” IEEJ Transactions on Sensors and Micromachines, vol. 136, no. 10, 2016, pp. 454–459. https://doi.org/10.1541/ieejsmas.136.454.

Chicago

Sato, Ryo, Takahiro Kamada, and Takashi Mineta. 2016. “Reversible Actuation Micro Gripper with Thick SMA Film for Bio-sheet Handing.” IEEJ Transactions on Sensors and Micromachines 136 (10): 454–459. https://doi.org/10.1541/ieejsmas.136.454.

Harvard

Sato, R., Kamada, T. and Mineta, T. (2016) ‘Reversible Actuation Micro Gripper with Thick SMA Film for Bio-sheet Handing’, IEEJ Transactions on Sensors and Micromachines, 136(10), pp. 454–459. doi:10.1541/ieejsmas.136.454.

IEEE

R. Sato, T. Kamada, and T. Mineta, “Reversible Actuation Micro Gripper with Thick SMA Film for Bio-sheet Handing,” IEEJ Transactions on Sensors and Micromachines, vol. 136, no. 10, pp. 454–459, 2016, doi: 10.1541/ieejsmas.136.454.

BibTeX

@article{sato2016reversible,
  title     = {{Reversible Actuation Micro Gripper with Thick SMA Film for Bio-sheet Handing}},
  author    = {Sato, Ryo and Kamada, Takahiro and Mineta, Takashi},
  journal   = {IEEJ Transactions on Sensors and Micromachines},
  year      = {2016},
  volume    = {136},
  number    = {10},
  pages     = {454--459},
  doi       = {10.1541/ieejsmas.136.454},
  url       = {https://doi.org/10.1541/ieejsmas.136.454}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies

  • microgripper
  • shape memory alloys
  • flash evaporation
  • reversible actuation
  • strain gauges
  • film stress
  • spring stiffness
  • gripping force

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Sato, R., Kamada, T., & Mineta, T. (2016). Reversible Actuation Micro Gripper with Thick SMA Film for Bio-sheet Handing. IEEJ Transactions on Sensors and Micromachines, 136(10), 454–459. https://doi.org/10.1541/ieejsmas.136.454

How many times has this paper been cited?

2 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at IEEJ Transactions on Sensors and Micromachines: sign in and open the PDF from this page.

Who wrote this paper?

Ryo Sato, Takahiro Kamada, Takashi Mineta.

What is the DOI of this paper?

10.1541/ieejsmas.136.454, permanently at https://doi.org/10.1541/ieejsmas.136.454. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.