Journal article · 2015 · Open access

Reproducibility of Facial Soft Tissue Thickness Measurements Using Cone‐Beam CT Images According to the Measurement Methods

Hyeon‐Shik Hwang, Seon‐Yeong Choe, Ji‐Sup Hwang, Danal Moon, Yanan Hou, Won Joon Lee, Caroline M. Wilkinson

Journal of Forensic Sciences, 60(4), 957–965 · Published 4 April 2015 · DOI 10.1111/1556-4029.12766

Open PDFView at the publisherCite this paper

In brief

“Reproducibility of Facial Soft Tissue Thickness Measurements Using Cone‐Beam CT Images According to the Measurement Methods” is a 2015 journal article by Hyeon‐Shik Hwang and 6 co-authors, published in Journal of Forensic Sciences. OpenAlex counts 50 citations as of 24 November 2026. It is open access under a public domain licence: the full text is free to read at Discovery Research Portal (University of Dundee).

Citations
50
Most cited in
2018 (7)
Field-weighted impact
4.42
References
22
Authors
7

Abstract

The purpose of this study was to establish the reproducibility of facial soft tissue (ST) thickness measurements by comparing three different measurement methods applied at 32 landmarks on three-dimensional cone-beam computed tomography (CBCT) images. Two observers carried out the measurements of facial ST thickness of 20 adult subjects using CBCT scan data, and inter- and intra-observer reproducibilities were evaluated. The measurement method of "perpendicular to bone" resulted in high inter- and intra-observer reproducibility at all 32 landmarks. In contrast, the "perpendicular to skin" method and "direct" method, which measures a distance between one point on bone and the other point on skin, presented low reproducibility. The results indicate that reproducibility could be increased by identifying the landmarks on hard tissue images, rather than on ST images, and the landmark description used in this study can be used in the establishment of reliable tissue depth data using CBCT images.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Hwang, H., Choe, S., Hwang, J., Moon, D., Hou, Y., Lee, W. J., & Wilkinson, C. M. (2015). Reproducibility of Facial Soft Tissue Thickness Measurements Using Cone‐Beam CT Images According to the Measurement Methods. Journal of Forensic Sciences, 60(4), 957–965. https://doi.org/10.1111/1556-4029.12766

MLA 9

Hwang, Hyeon‐Shik, et al. “Reproducibility of Facial Soft Tissue Thickness Measurements Using Cone‐Beam CT Images According to the Measurement Methods.” Journal of Forensic Sciences, vol. 60, no. 4, 2015, pp. 957–965. https://doi.org/10.1111/1556-4029.12766.

Chicago

Hwang, Hyeon‐Shik, Seon‐Yeong Choe, Ji‐Sup Hwang, Danal Moon, Yanan Hou, Won Joon Lee, and Caroline M. Wilkinson. 2015. “Reproducibility of Facial Soft Tissue Thickness Measurements Using Cone‐Beam CT Images According to the Measurement Methods.” Journal of Forensic Sciences 60 (4): 957–965. https://doi.org/10.1111/1556-4029.12766.

Harvard

Hwang, H. et al. (2015) ‘Reproducibility of Facial Soft Tissue Thickness Measurements Using Cone‐Beam CT Images According to the Measurement Methods’, Journal of Forensic Sciences, 60(4), pp. 957–965. doi:10.1111/1556-4029.12766.

IEEE

H. Hwang et al., “Reproducibility of Facial Soft Tissue Thickness Measurements Using Cone‐Beam CT Images According to the Measurement Methods,” Journal of Forensic Sciences, vol. 60, no. 4, pp. 957–965, 2015, doi: 10.1111/1556-4029.12766.

BibTeX

@article{hwang2015reproducibility,
  title     = {{Reproducibility of Facial Soft Tissue Thickness Measurements Using Cone‐Beam CT Images According to the Measurement Methods}},
  author    = {Hwang, Hyeon‐Shik and Choe, Seon‐Yeong and Hwang, Ji‐Sup and Moon, Danal and Hou, Yanan and Lee, Won Joon and Wilkinson, Caroline M.},
  journal   = {Journal of Forensic Sciences},
  year      = {2015},
  volume    = {60},
  number    = {4},
  pages     = {957--965},
  doi       = {10.1111/1556-4029.12766},
  url       = {https://doi.org/10.1111/1556-4029.12766}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201711
201877
201955
202055
202177
202255
202344
202411
202566
202633

Its field-weighted citation impact is 4.42: it has been cited 4.42 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Radiography and Imaging

  • facial soft tissue thickness
  • cone-beam computed tomography
  • measurement reproducibility
  • interobserver agreement
  • intraobserver agreement
  • facial landmarks
  • measurement method comparison

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Hwang, H., Choe, S., Hwang, J., Moon, D., Hou, Y., Lee, W. J., & Wilkinson, C. M. (2015). Reproducibility of Facial Soft Tissue Thickness Measurements Using Cone‐Beam CT Images According to the Measurement Methods. Journal of Forensic Sciences, 60(4), 957–965. https://doi.org/10.1111/1556-4029.12766

How many times has this paper been cited?

50 times, according to OpenAlex on 24 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Discovery Research Portal (University of Dundee): sign in and open the PDF from this page.

Who wrote this paper?

Hyeon‐Shik Hwang, Seon‐Yeong Choe, Ji‐Sup Hwang, Danal Moon, Yanan Hou, Won Joon Lee, Caroline M. Wilkinson.

What is the DOI of this paper?

10.1111/1556-4029.12766, permanently at https://doi.org/10.1111/1556-4029.12766. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 24 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.