Journal article · 2007 · Open access
Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis
BMC Molecular Biology, 8(1), 113 · Published 20 December 2007 · DOI 10.1186/1471-2199-8-113
In brief
“Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis” is a 2007 journal article by Štefan Číkoš and 2 co-authors, published in BMC Molecular Biology. OpenAlex counts 451 citations as of 18 November 2026, which puts it in the top 1% of works published in 2007 by citations. It is open access under a CC BY licence: the full text is free to read at BMC Molecular Biology.
- Citations
- 451
- Most cited in
- 2020 (32)
- Field-weighted impact
- 6.72
- References
- 26
- Authors
- 3
Abstract
BACKGROUND: Fluorescent data obtained from real-time PCR must be processed by some method of data analysis to obtain the relative quantity of target mRNA. The method chosen for data analysis can strongly influence results of the quantification. RESULTS: To compare the performance of six techniques which are currently used for analysing fluorescent data in real-time PCR relative quantification, we quantified four cytokine transcripts (IL-1beta, IL-6 TNF-alpha, and GM-CSF) in an in vivo model of colonic inflammation. Accuracy of the methods was tested by quantification on samples with known relative amounts of target mRNAs. Reproducibility of the methods was estimated by the determination of the intra-assay and inter-assay variability. Cytokine expression normalized to the expression of three reference genes (ACTB, HPRT, SDHA) was then determined using the six methods for data analysis. The best results were obtained with the relative standard curve method, comparative Ct method and with DART-PCR, LinRegPCR and Liu & Saint exponential methods when average amplification efficiency was used. The use of individual amplification efficiencies in DART-PCR, LinRegPCR and Liu & Saint exponential methods significantly impaired the results. The sigmoid curve-fitting (SCF) method produced medium performance; the results indicate that the use of appropriate type of fluorescence data and in some instances manual selection of the number of amplification cycles included in the analysis is necessary when the SCF method is applied. We also compared amplification efficiencies (E) and found that although the E values determined by different methods of analysis were not identical, all the methods were capable to identify two genes whose E values significantly differed from other genes. CONCLUSION: Our results show that all the tested methods can provide quantitative values reflecting the amounts of measured mRNA in samples, but they differ in their accuracy and reproducibility. Selection of the appropriate method can also depend on the design of a particular experiment. The advantages and disadvantages of the methods in different applications are discussed.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Číkoš, Š., Špirková, A., & Koppel, J. (2007). Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis. BMC Molecular Biology, 8(1), 113. https://doi.org/10.1186/1471-2199-8-113
MLA 9
Číkoš, Štefan, et al. “Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis.” BMC Molecular Biology, vol. 8, no. 1, 2007, p. 113. https://doi.org/10.1186/1471-2199-8-113.
Chicago
Číkoš, Štefan, Alexandra Špirková, and Juraj Koppel. 2007. “Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis.” BMC Molecular Biology 8 (1): 113. https://doi.org/10.1186/1471-2199-8-113.
Harvard
Číkoš, Š., Špirková, A. and Koppel, J. (2007) ‘Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis’, BMC Molecular Biology, 8(1), p. 113. doi:10.1186/1471-2199-8-113.
IEEE
Š. Číkoš, A. Špirková, and J. Koppel, “Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis,” BMC Molecular Biology, vol. 8, no. 1, p. 113, 2007, doi: 10.1186/1471-2199-8-113.
BibTeX
@article{cikos2007relative,
title = {{Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis}},
author = {Číkoš, Štefan and Špirková, Alexandra and Koppel, Juraj},
journal = {BMC Molecular Biology},
year = {2007},
volume = {8},
number = {1},
pages = {113},
doi = {10.1186/1471-2199-8-113},
url = {https://doi.org/10.1186/1471-2199-8-113}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2017 | 20 | |
| 2018 | 23 | |
| 2019 | 17 | |
| 2020 | 32 | |
| 2021 | 26 | |
| 2022 | 18 | |
| 2023 | 16 | |
| 2024 | 21 | |
| 2025 | 15 | |
| 2026 | 17 |
Its field-weighted citation impact is 6.72: it has been cited 6.72 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- sigmoid curve fitting
- amplification efficiency
- cytokine gene expression
- colonic inflammation
- reference genes
- reproducibility
Work with this paper
Most-cited papers in Biochemistry, Genetics and Molecular Biology
- PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENTOliver H. Lowry, NiraJ. Rosebrough, A. Lewis Farr and 1 more · Journal of Biological Chemistry · 1951 · 316,470 citations
- A Rapid and Sensitive Method for the Quantitation of Microgram Quantities of Protein Utilizing the Principle of Protein-Dye BindingM Bradford · Analytical Biochemistry · 1976 · 256,780 citations
- Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT MethodKenneth J. Livak, Thomas D. Schmittgen · Methods · 2001 · 184,418 citations
- Molecular Cloning: A Laboratory ManualJoseph Sambrook, Elisabeth Fritsch, Tom Maniatis · UCLA - Biblioteca de Ciencias de la Salud · 1989 · 133,493 citations
- Basic Local Alignment Search ToolStephen F. Altschul, Warren R. Gish, Webb Miller and 2 more · Journal of Molecular Biology · 1990 · 100,529 citations
All highly cited Biochemistry, Genetics and Molecular Biology papers
Questions about this paper
How do I cite this paper in APA style?
Číkoš, Š., Špirková, A., & Koppel, J. (2007). Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis. BMC Molecular Biology, 8(1), 113. https://doi.org/10.1186/1471-2199-8-113
How many times has this paper been cited?
451 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at BMC Molecular Biology: sign in and open the PDF from this page.
Who wrote this paper?
Štefan Číkoš, Alexandra Špirková, Juraj Koppel.
What is the DOI of this paper?
10.1186/1471-2199-8-113, permanently at https://doi.org/10.1186/1471-2199-8-113. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.