Journal article · 2026 · Open access
Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan‐body for full‐arch implants
Journal of Prosthodontics · Published 6 October 2026 · DOI 10.1111/jopr.70237
In brief
“Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan‐body for full‐arch implants” is a 2026 journal article by Sherif Aly Sadek and 3 co-authors, published in Journal of Prosthodontics. OpenAlex counts 0 citations as of 18 November 2026. It is open access under a CC BY-NC-ND licence: the full text is free to read at Journal of Prosthodontics.
- Citations
- 0
- References
- 37
- Authors
- 4
Abstract
PURPOSE: To compare the relative accuracy of intraoral photogrammetry (IPG) and intraoral scan (IOS) with conventional scan bodies (IOS-CB) for complete-arch implant impressions, using the conventional splinted open-tray impression digitized with a laboratory scanner (COT-LS) as the reference standard. MATERIALS AND METHODS: Twenty-six edentulous maxillary arches restored with four BioHorizons Tapered Internal implants supporting multiunit abutments were included. For each patient, three impressions were obtained: (1) a conventional splinted open-tray impression poured in type IV dental stone and scanned with a laboratory extraoral scanner to generate the COT-LS dataset; (2) an IOS-CB using the Aoralscan Elite, with scan bodies present from the outset of a single continuous scanning pass; and (3) an IPG scan using the same device in photogrammetry mode with dedicated scan flags mounted on the multiunit abutments. STL files were analyzed in Geomagic Control X, with the COT-LS dataset used as the reference. Relative accuracy was quantified as centroid-based linear deviation from COT-LS following best-fit alignment. Measurement reproducibility was assessed using intraclass correlation coefficients (ICC) from two independent examiners analyzing the same datasets. The IOS-CB and IPG datasets were superimposed to calculate linear and three-dimensional positional deviations (µm). A repeated-measures two-way ANOVA with Tukey post hoc testing was performed (p < 0.05). RESULTS: IPG demonstrated significantly lower deviations than IOS-CB in the full-arch, anterior right, and anterior left regions (p < 0.001). IOS-CB showed significantly lower deviations than IPG in both posterior right and posterior left regions (p < 0.001). The full-arch mean deviation was lower for IPG (39.2 µm) than IOS-CB (45.1 µm). All deviations for both techniques remained within the clinically acceptable threshold for passive fit. ICC values for measurement reproducibility exceeded 0.95 for both techniques. CONCLUSIONS: Within the limitations of this clinical study, IPG demonstrated a lower full-arch mean deviation than IOS-CB when evaluated against the COT-LS reference. However, as the inherent dimensional error of the COT-LS reference may approach or exceed the 5.9 µm between-technique difference, this finding should be considered hypothesis-generating rather than confirmatory evidence of a trueness advantage. Measurement reproducibility was high for both techniques (ICC >0.95).
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Sadek, S. A., Gaber, M. S., Mostafa, M. H., & Zamzam, H. (2026). Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan‐body for full‐arch implants. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70237
MLA 9
Sadek, Sherif Aly, et al. “Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan‐body for full‐arch implants.” Journal of Prosthodontics, 2026. https://doi.org/10.1111/jopr.70237.
Chicago
Sadek, Sherif Aly, Mona Samir Gaber, Marwa Hassan Mostafa, and Hadiel Zamzam. 2026. “Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan‐body for full‐arch implants.” Journal of Prosthodontics. https://doi.org/10.1111/jopr.70237.
Harvard
Sadek, S. A. et al. (2026) ‘Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan‐body for full‐arch implants’, Journal of Prosthodontics. doi:10.1111/jopr.70237.
IEEE
S. A. Sadek, M. S. Gaber, M. H. Mostafa, and H. Zamzam, “Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan‐body for full‐arch implants,” Journal of Prosthodontics, 2026, doi: 10.1111/jopr.70237.
BibTeX
@article{sadek2026relative,
title = {{Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan‐body for full‐arch implants}},
author = {Sadek, Sherif Aly and Gaber, Mona Samir and Mostafa, Marwa Hassan and Zamzam, Hadiel},
journal = {Journal of Prosthodontics},
year = {2026},
doi = {10.1111/jopr.70237},
url = {https://doi.org/10.1111/jopr.70237}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- intraoral scanning
- scan body
- edentulous maxilla
- full-arch dental implants
- dimensional accuracy
- open tray impression
- measurement reproducibility
- digital dentistry
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Sadek, S. A., Gaber, M. S., Mostafa, M. H., & Zamzam, H. (2026). Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan‐body for full‐arch implants. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70237
How many times has this paper been cited?
0 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Journal of Prosthodontics: sign in and open the PDF from this page.
Who wrote this paper?
Sherif Aly Sadek, Mona Samir Gaber, Marwa Hassan Mostafa, Hadiel Zamzam.
What is the DOI of this paper?
10.1111/jopr.70237, permanently at https://doi.org/10.1111/jopr.70237. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.