Journal article · 2011 · Open access

Real‐Time Reverse Transcription Polymerase Chain Reaction to Measure mRNA: Use, Limitations, and Presentation of Results

Ellen C. Jensen

The Anatomical Record, 295(1), 1–3 · Published 18 November 2011 · DOI 10.1002/ar.21487

Open PDFView at the publisherCite this paper

In brief

“Real‐Time Reverse Transcription Polymerase Chain Reaction to Measure mRNA: Use, Limitations, and Presentation of Results” is a 2011 journal article by Ellen C. Jensen, published in The Anatomical Record. OpenAlex counts 39 citations as of 22 November 2026. It is open access: the full text is free to read at The Anatomical Record.

Citations
39
Most cited in
2023 (8)
Field-weighted impact
0.66
References
12
Authors
1

Abstract

Quantitative polymerase chain reaction (PCR) was originally developed for DNA quantitation. There are various applications for quantitative PCR, and it is now increasingly used for measurement of messenger RNA (mRNA) levels (VanGuilder et al., 2008). Quantitative PCR became well known with the introduction of real-time quantitative PCR methods. The focus of this article is the use of quantitative real-time reverse transcription PCR for the measurement of mRNA. Real-time PCR is a technique based on PCR, with the key feature that the amplified product is detected as the reaction progresses in "real-time." Real-time PCR is combined with the method of reverse transcription to quantify mRNA, which is often used to infer gene expression. There is a lack of consensus on the best method for performing and interpreting real-time reverse transcription PCR experiments for measurement of mRNA. This review focuses on clarifying the principles behind the real-time reverse transcription PCR, indicates what data should be used for analysis and briefly suggests what details of the method should be presented in publications. Real-time PCR, also called "quantitative real-time PCR," has a number of different abbreviations used in the literature. This can be confusing to the reader. Different abbreviations include RTQ-PCR, Q-PCR, qRT-PCR, or qPCR. The abbreviation "RT-PCR" should denote "reverse transcription PCR" and NOT "real-time PCR" (see below for the difference between the two methods); but this is not always the case, which can add further confusion to the nomenclature. When real-time PCR is combined with the method of reverse transcription to quantify mRNA, the suggested preferred abbreviation is "real-time RT-PCR", which will be used throughout this article. Reverse transcription PCR is an older method used for detection of low-abundance mRNA. An RNA strand is first reverse transcribed into its DNA complement (cDNA) and the resulting cDNA is amplified using traditional PCR. However, conventional RT-PCR is a time-consuming technique that has limitations compared with the real-time RT-PCR method (Mackay et al., 2002). In RT-PCR, the product is often detected using ethidium bromide, which has a low sensitivity, and results are not always reliable. In addition, results are variable because they are measured at the plateau phase (as opposed to the exponential phase) of the reaction. There is also an increased risk of sample cross-contamination because of post-amplification processing. One of the biggest disadvantages of RT-PCR is that it is a semi- or a low-quantitative technique, where the amplified product (amplicon) can be visualized only after the amplification ends. Real-time RT-PCR is an extremely sensitive cost-effective method. In contrast to the conventional RT-PCR, the…

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Jensen, E. C. (2011). Real‐Time Reverse Transcription Polymerase Chain Reaction to Measure mRNA: Use, Limitations, and Presentation of Results. The Anatomical Record, 295(1), 1–3. https://doi.org/10.1002/ar.21487

MLA 9

Jensen, Ellen C. “Real‐Time Reverse Transcription Polymerase Chain Reaction to Measure mRNA: Use, Limitations, and Presentation of Results.” The Anatomical Record, vol. 295, no. 1, 2011, pp. 1–3. https://doi.org/10.1002/ar.21487.

Chicago

Jensen, Ellen C. 2011. “Real‐Time Reverse Transcription Polymerase Chain Reaction to Measure mRNA: Use, Limitations, and Presentation of Results.” The Anatomical Record 295 (1): 1–3. https://doi.org/10.1002/ar.21487.

Harvard

Jensen, E. C. (2011) ‘Real‐Time Reverse Transcription Polymerase Chain Reaction to Measure mRNA: Use, Limitations, and Presentation of Results’, The Anatomical Record, 295(1), pp. 1–3. doi:10.1002/ar.21487.

IEEE

E. C. Jensen, “Real‐Time Reverse Transcription Polymerase Chain Reaction to Measure mRNA: Use, Limitations, and Presentation of Results,” The Anatomical Record, vol. 295, no. 1, pp. 1–3, 2011, doi: 10.1002/ar.21487.

BibTeX

@article{jensen2011real,
  title     = {{Real‐Time Reverse Transcription Polymerase Chain Reaction to Measure mRNA: Use, Limitations, and Presentation of Results}},
  author    = {Jensen, Ellen C.},
  journal   = {The Anatomical Record},
  year      = {2011},
  volume    = {295},
  number    = {1},
  pages     = {1--3},
  doi       = {10.1002/ar.21487},
  url       = {https://doi.org/10.1002/ar.21487}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201555
201611
201822
201944
202022
202133
202222
202388
202433
202622

Its field-weighted citation impact is 0.66: it has been cited 0.66 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications

  • real-time reverse transcription PCR
  • real-time PCR
  • mRNA quantification
  • gene expression quantification
  • RT-PCR
  • PCR product detection
  • cDNA amplification
  • PCR product sequencing

Work with this paper

Most-cited papers in Biochemistry, Genetics and Molecular Biology

All highly cited Biochemistry, Genetics and Molecular Biology papers

Questions about this paper

How do I cite this paper in APA style?

Jensen, E. C. (2011). Real‐Time Reverse Transcription Polymerase Chain Reaction to Measure mRNA: Use, Limitations, and Presentation of Results. The Anatomical Record, 295(1), 1–3. https://doi.org/10.1002/ar.21487

How many times has this paper been cited?

39 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at The Anatomical Record: sign in and open the PDF from this page.

Who wrote this paper?

Ellen C. Jensen.

What is the DOI of this paper?

10.1002/ar.21487, permanently at https://doi.org/10.1002/ar.21487. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.