Journal article · 1996 · Open access

Quality improvement of plasma-beam-deposited amorphous hydrogenated carbon with higher growth rate

John W A M Gielen, M. C. M. van de Sanden, Prm Patrick Kleuskens, D.C. Schram

Plasma Sources Science and Technology, 5(3), 492–498 · Published 1 August 1996 · DOI 10.1088/0963-0252/5/3/016

Read the free full textView at the publisherCite this paper

In brief

“Quality improvement of plasma-beam-deposited amorphous hydrogenated carbon with higher growth rate” is a 1996 journal article by John W A M Gielen and 3 co-authors, published in Plasma Sources Science and Technology. OpenAlex counts 40 citations as of 16 November 2026. It is open access: the full text is free to read at TU/e Research Portal.

Citations
40
Most cited in
2012 (1)
Field-weighted impact
2.92
References
19
Authors
4

Abstract

An improved plasma beam deposition set-up, based on an expanding thermal plasma, is presented. Amorphous hydrogenated carbon films have been deposited on glass and crystalline silicon, under variation of the arc current and admixed acetylene flow. The films have been analysed ex situ with infrared absorption spectroscopy, broadband visible light transmission and nano-indentation measurements. These techniques reveal the growth rate, refractive index, bonded C - H density, optical bandgap and hardness. The growth rate and refractive index are found to increase with decreasing arc current and increasing acetylene flow admixture. The quality of the films in terms of refractive index and hardness increases with increasing growth rate and inverse energy coefficient, whereas the bonded hydrogen concentration and optical bandgap then decrease. From comparison of the growth rate dependency with the inverse energy coefficient dependency, we conclude that the growth rate is the preferred parameter in terms of which to describe the film properties because it is directly related to the plasma composition.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Gielen, J. W. A. M., van de Sanden, M. C. M., Kleuskens, P. P., & Schram, D. (1996). Quality improvement of plasma-beam-deposited amorphous hydrogenated carbon with higher growth rate. Plasma Sources Science and Technology, 5(3), 492–498. https://doi.org/10.1088/0963-0252/5/3/016

MLA 9

Gielen, John W A M, et al. “Quality improvement of plasma-beam-deposited amorphous hydrogenated carbon with higher growth rate.” Plasma Sources Science and Technology, vol. 5, no. 3, 1996, pp. 492–498. https://doi.org/10.1088/0963-0252/5/3/016.

Chicago

Gielen, John W A M, M. C. M. van de Sanden, Prm Patrick Kleuskens, and D.C. Schram. 1996. “Quality improvement of plasma-beam-deposited amorphous hydrogenated carbon with higher growth rate.” Plasma Sources Science and Technology 5 (3): 492–498. https://doi.org/10.1088/0963-0252/5/3/016.

Harvard

Gielen, J. W. A. M. et al. (1996) ‘Quality improvement of plasma-beam-deposited amorphous hydrogenated carbon with higher growth rate’, Plasma Sources Science and Technology, 5(3), pp. 492–498. doi:10.1088/0963-0252/5/3/016.

IEEE

J. W. A. M. Gielen, M. C. M. van de Sanden, P. P. Kleuskens, and D. Schram, “Quality improvement of plasma-beam-deposited amorphous hydrogenated carbon with higher growth rate,” Plasma Sources Science and Technology, vol. 5, no. 3, pp. 492–498, 1996, doi: 10.1088/0963-0252/5/3/016.

BibTeX

@article{gielen1996quality,
  title     = {{Quality improvement of plasma-beam-deposited amorphous hydrogenated carbon with higher growth rate}},
  author    = {Gielen, John W A M and van de Sanden, M. C. M. and Kleuskens, Prm Patrick and Schram, D.C.},
  journal   = {Plasma Sources Science and Technology},
  year      = {1996},
  volume    = {5},
  number    = {3},
  pages     = {492--498},
  doi       = {10.1088/0963-0252/5/3/016},
  url       = {https://doi.org/10.1088/0963-0252/5/3/016}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201211
201311
201411
201811

Its field-weighted citation impact is 2.92: it has been cited 2.92 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Materials Science › Materials Chemistry › Diamond and Carbon-based Materials Research

  • hydrogenated amorphous carbon
  • expanding thermal plasma
  • growth rate (crystal and thin-film growth)
  • refractive index
  • optical band gap
  • film hardness
  • arc current
  • crystalline silicon substrates

Work with this paper

Most-cited papers in Materials Science

All highly cited Materials Science papers

Questions about this paper

How do I cite this paper in APA style?

Gielen, J. W. A. M., van de Sanden, M. C. M., Kleuskens, P. P., & Schram, D. (1996). Quality improvement of plasma-beam-deposited amorphous hydrogenated carbon with higher growth rate. Plasma Sources Science and Technology, 5(3), 492–498. https://doi.org/10.1088/0963-0252/5/3/016

How many times has this paper been cited?

40 times, according to OpenAlex on 16 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access: read the free full text at TU/e Research Portal.

Who wrote this paper?

John W A M Gielen, M. C. M. van de Sanden, Prm Patrick Kleuskens, D.C. Schram.

What is the DOI of this paper?

10.1088/0963-0252/5/3/016. The permanent link is https://doi.org/10.1088/0963-0252/5/3/016.

Bibliographic data from OpenAlex (CC0), last checked 16 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.