Journal article · 2026 · Open access

Probe Accuracy and Agreement and Patient Preferences in Peri‐Implant Probing Depth Assessment: A Cross‐Sectional Study

Magdalena Mayol, Kristina Bertl, Nikolaos Pandis, Andreas Stavropoulos

Clinical Oral Implants Research · Published 5 November 2026 · DOI 10.1111/clr.70195

Open PDFView at the publisherCite this paper

In brief

“Probe Accuracy and Agreement and Patient Preferences in Peri‐Implant Probing Depth Assessment: A Cross‐Sectional Study” is a 2026 journal article by Magdalena Mayol and 3 co-authors, published in Clinical Oral Implants Research. OpenAlex counts 0 citations as of 16 November 2026. It is open access under a CC BY licence: the full text is free to read at Clinical Oral Implants Research.

Citations
0
References
32
Authors
4

Abstract

OBJECTIVES: To record the accuracy and agreement of three types of probes (i.e., a common metal probe and two types of flexible probes) for peri-implant probing depth (PD) assessment, including patient-reported outcomes (PRO). METHODS: Fifty patients (85 implants) with an implant-supported restoration were included. Peri-implant PD was recorded with a metal, plastic, and electronic probe. Pain/discomfort and patient preference were registered. After removing the prosthetic restoration, the correct peri-implant PD (cPD), the mucosal height (MH), and the PD measured from the implant level (iPD) were assessed. RESULTS: Good accuracy and agreement were noted for PD measurements with the metal and plastic probe. They differed in approximately 80% of the measurements by < 1.5 mm from cPD, and on average, an underestimation of 0.5 mm occurred. The accuracy of the metal probe was negatively influenced by a thick peri-implant mucosal phenotype. A direct comparison of the metal and plastic probes showed perfect agreement in 68.7% of the cases. Patients reported significantly less pain/discomfort when the plastic probe was used compared to the metal probe. The electronic probe was unreliable and differed by ≥ 1.5 mm from cPD in 65% of the measurements. CONCLUSIONS: While the electronic probe was unreliable, the metal and plastic probes were relatively accurate and comparable for assessing peri-implant PD; the plastic probe caused less pain/discomfort. However, in approximately 1/5 of the measurements a ≥ 1.5 mm deviation from the correct value (cPD) may occur, and the accuracy of the metal probe appears negatively influenced by a thick peri-implant mucosal phenotype. TRIAL REGISTRATION: The protocol was registered at clinicaltrials.gov (NCT05332327).

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Mayol, M., Bertl, K., Pandis, N., & Stavropoulos, A. (2026). Probe Accuracy and Agreement and Patient Preferences in Peri‐Implant Probing Depth Assessment: A Cross‐Sectional Study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70195

MLA 9

Mayol, Magdalena, et al. “Probe Accuracy and Agreement and Patient Preferences in Peri‐Implant Probing Depth Assessment: A Cross‐Sectional Study.” Clinical Oral Implants Research, 2026. https://doi.org/10.1111/clr.70195.

Chicago

Mayol, Magdalena, Kristina Bertl, Nikolaos Pandis, and Andreas Stavropoulos. 2026. “Probe Accuracy and Agreement and Patient Preferences in Peri‐Implant Probing Depth Assessment: A Cross‐Sectional Study.” Clinical Oral Implants Research. https://doi.org/10.1111/clr.70195.

Harvard

Mayol, M. et al. (2026) ‘Probe Accuracy and Agreement and Patient Preferences in Peri‐Implant Probing Depth Assessment: A Cross‐Sectional Study’, Clinical Oral Implants Research. doi:10.1111/clr.70195.

IEEE

M. Mayol, K. Bertl, N. Pandis, and A. Stavropoulos, “Probe Accuracy and Agreement and Patient Preferences in Peri‐Implant Probing Depth Assessment: A Cross‐Sectional Study,” Clinical Oral Implants Research, 2026, doi: 10.1111/clr.70195.

BibTeX

@article{mayol2026probe,
  title     = {{Probe Accuracy and Agreement and Patient Preferences in Peri‐Implant Probing Depth Assessment: A Cross‐Sectional Study}},
  author    = {Mayol, Magdalena and Bertl, Kristina and Pandis, Nikolaos and Stavropoulos, Andreas},
  journal   = {Clinical Oral Implants Research},
  year      = {2026},
  doi       = {10.1111/clr.70195},
  url       = {https://doi.org/10.1111/clr.70195}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes

  • peri-implant probing depth
  • dental implants
  • flexible probe
  • metal probe
  • patient-reported outcomes
  • measurement agreement
  • patient discomfort
  • implant-supported prostheses

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Mayol, M., Bertl, K., Pandis, N., & Stavropoulos, A. (2026). Probe Accuracy and Agreement and Patient Preferences in Peri‐Implant Probing Depth Assessment: A Cross‐Sectional Study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70195

How many times has this paper been cited?

0 times, according to OpenAlex on 16 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Clinical Oral Implants Research: sign in and open the PDF from this page.

Who wrote this paper?

Magdalena Mayol, Kristina Bertl, Nikolaos Pandis, Andreas Stavropoulos.

What is the DOI of this paper?

10.1111/clr.70195, permanently at https://doi.org/10.1111/clr.70195. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 16 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.