Dissertation · 2017 · Open access
Prescriptive pattern and clinical decision making in complicated endodontic cases using cone-beam computed tomography.
cIRcle (University of British Columbia) · Published 1 January 2017 · DOI 10.14288/1.0357035
In brief
“Prescriptive pattern and clinical decision making in complicated endodontic cases using cone-beam computed tomography.” is a 2017 dissertation by Bhatt, Meeta, published in cIRcle (University of British Columbia). OpenAlex counts 2 citations as of 19 November 2026. It is open access under a CC BY-NC-ND licence: the full text is free to read at cIRcle (University of British Columbia).
- Citations
- 2
- Most cited in
- 2019 (2)
- References
- 124
- Authors
- 1
Abstract
Purpose: Cone Beam Computed Tomography (CBCT) is an advanced but new imaging technique used in dentistry. Although it already has acquired a substantial literature, that literature does not include evidence-based evidence both for its indications-for-use and for its efficacy in comparison to the conventional approach to diagnosis and treatment planning. Aims: To determine the pattern of prescription of CBCT by all UBC dental programs with particular regard to the field-of-view (FOV). To determine whether the CBCT prescriptions by the Graduate Endodontics Program were compliant with the joint American-Academy-of-Oral-and-Maxillofacial-Radiology and American-Academy-of-Endodontics (AAOMR/AAE) position statement (viz guidelines). To determine by reference to the EPR whether CBCT changed the original diagnosis and/or treatment plans based on the initial clinical examination and the conventional radiographic. Methods: Ethics approval certificates H14-02191 and H15-03507 were granted for this retrospective study. All CBCT prescriptions were audited. The audit revealed that CBCT prescriptions by the Graduate Endodontics program were for a wide range of clinical reasons and worthy of further study. The pattern of prescription of CBCT was reviewed, by reference to electronic patient record (EPR), to determine whether it was compliant with the AAOMR/AAE guidelines. The statistical test, Chi-square was used. Results: All but one CBCT in the audit were for small and medium-sized FOVS. All 128 CBCT prescriptions (in 110 consecutive patients) were AAOMR/AAE-guidelines compliant. CBCT identified significantly more features than conventional radiography (p<0.001), particularly with regards to the identification of periapical lesions (p = 0.002), missed canals (p < 0.001), vertical root fractures (p = 0.004) and complex anatomy (p = 0.008). The significant results were seen with respect to change in diagnosis (p<0.001), change in treatment plan (p< 0.005). The AAOMR/AAE recommendations were found to be incomplete. Conclusion: CBCT permitted the identification of more numbers of periapical lesions, missed canal, complex anatomy and vertical root fracture than initially observable on conventional radiography. This study is perhaps the first to ‘road-test’ the AAOMR/AAE guidelines in an authentic clinical environment. It identified an important hiatus in these guidelines; they did not consider missed/extra canals in teeth which required endodontic re-treatment.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Meeta, B. (2017). Prescriptive pattern and clinical decision making in complicated endodontic cases using cone-beam computed tomography. cIRcle (University of British Columbia). https://doi.org/10.14288/1.0357035
MLA 9
Meeta, Bhatt,. “Prescriptive pattern and clinical decision making in complicated endodontic cases using cone-beam computed tomography.” cIRcle (University of British Columbia), 2017. https://doi.org/10.14288/1.0357035.
Chicago
Meeta, Bhatt,. 2017. “Prescriptive pattern and clinical decision making in complicated endodontic cases using cone-beam computed tomography.” cIRcle (University of British Columbia). https://doi.org/10.14288/1.0357035.
Harvard
Meeta, B. (2017) ‘Prescriptive pattern and clinical decision making in complicated endodontic cases using cone-beam computed tomography.’, cIRcle (University of British Columbia). doi:10.14288/1.0357035.
IEEE
B. Meeta, “Prescriptive pattern and clinical decision making in complicated endodontic cases using cone-beam computed tomography.,” cIRcle (University of British Columbia), 2017, doi: 10.14288/1.0357035.
BibTeX
@phdthesis{meeta2017prescriptive,
title = {{Prescriptive pattern and clinical decision making in complicated endodontic cases using cone-beam computed tomography.}},
author = {Meeta, Bhatt,},
year = {2017},
doi = {10.14288/1.0357035},
url = {https://doi.org/10.14288/1.0357035}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Health Sciences › Dentistry › Oral Surgery › Dental Radiography and Imaging
- cone-beam computed tomography
- endodontics
- field of view
- clinical decision-making
- periapical lesions
- missed canals
- vertical root fracture
- complex root canal anatomy
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Meeta, B. (2017). Prescriptive pattern and clinical decision making in complicated endodontic cases using cone-beam computed tomography. cIRcle (University of British Columbia). https://doi.org/10.14288/1.0357035
How many times has this paper been cited?
2 times, according to OpenAlex on 19 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at cIRcle (University of British Columbia): sign in and open the full text from this page.
Who wrote this paper?
Bhatt, Meeta.
What is the DOI of this paper?
10.14288/1.0357035, permanently at https://doi.org/10.14288/1.0357035. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 19 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.