Conference paper · 2024 · Open access

Pneumatically Operated Tendril-based Soft Hyper-Redundant Robotic Gripper

Shubhashis Sanyal, Anuj Shukla, Hrishi Sharad Pinjan, Piyush Tailor, Pyla Pavan Kumar, Saurav Suman, Surjeet Kumar Bhargav

Journal of Physics Conference Series, 2784(1), 012026 · Published 1 June 2024 · DOI 10.1088/1742-6596/2784/1/012026

Open full textCite this paper

In brief

“Pneumatically Operated Tendril-based Soft Hyper-Redundant Robotic Gripper” is a 2024 conference paper by Shubhashis Sanyal and 6 co-authors, published in Journal of Physics Conference Series. OpenAlex counts 0 citations as of 22 November 2026. It is open access under a CC BY licence: the full text is free to read at Journal of Physics Conference Series.

Citations
0
References
13
Authors
7

Abstract

The present work aims to design a soft, hyper redundant robotic gripper inspired by natural tendrils. The development of automation also requires extensive study in the field of biomimetic robotics. Most robotic systems are generally built using traditional rigid materials, such as hard plastics and metals. Creating accurate robotic systems necessitates the assembly of firm components connected at specific joints. Nonetheless, crafting a robotic system modeled after natural systems, comprising continuous deformable materials, is anticipated to match or exceed the capabilities of rigid robotic systems. Soft and highly redundant robotic grippers offer nearly limitless degrees of freedom (DOF) and elevated levels of kinematic redundancy. In the present work, a soft robotic gripper is proposed, inspired by plant tendrils that deform helically to hold the object on actuation. The work describes the initial design, material selection, method, important design parameters, an actuation mechanism and the simulation and analysis of the soft gripper. Such studies will be useful to industries and researchers in automation and biomimetic robotic systems.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Sanyal, S., Shukla, A., Pinjan, H. S., Tailor, P., Kumar, P. P., Suman, S., & Bhargav, S. K. (2024). Pneumatically Operated Tendril-based Soft Hyper-Redundant Robotic Gripper. Journal of Physics Conference Series, 2784(1), 012026. https://doi.org/10.1088/1742-6596/2784/1/012026

MLA 9

Sanyal, Shubhashis, et al. “Pneumatically Operated Tendril-based Soft Hyper-Redundant Robotic Gripper.” Journal of Physics Conference Series, vol. 2784, no. 1, 2024, p. 012026. https://doi.org/10.1088/1742-6596/2784/1/012026.

Chicago

Sanyal, Shubhashis, Anuj Shukla, Hrishi Sharad Pinjan, Piyush Tailor, Pyla Pavan Kumar, Saurav Suman, and Surjeet Kumar Bhargav. 2024. “Pneumatically Operated Tendril-based Soft Hyper-Redundant Robotic Gripper.” Journal of Physics Conference Series 2784 (1): 012026. https://doi.org/10.1088/1742-6596/2784/1/012026.

Harvard

Sanyal, S. et al. (2024) ‘Pneumatically Operated Tendril-based Soft Hyper-Redundant Robotic Gripper’, Journal of Physics Conference Series, 2784(1), p. 012026. doi:10.1088/1742-6596/2784/1/012026.

IEEE

S. Sanyal et al., “Pneumatically Operated Tendril-based Soft Hyper-Redundant Robotic Gripper,” Journal of Physics Conference Series, vol. 2784, no. 1, p. 012026, 2024, doi: 10.1088/1742-6596/2784/1/012026.

BibTeX

@inproceedings{sanyal2024pneumatically,
  title     = {{Pneumatically Operated Tendril-based Soft Hyper-Redundant Robotic Gripper}},
  author    = {Sanyal, Shubhashis and Shukla, Anuj and Pinjan, Hrishi Sharad and Tailor, Piyush and Kumar, Pyla Pavan and Suman, Saurav and Bhargav, Surjeet Kumar},
  booktitle = {Journal of Physics Conference Series},
  year      = {2024},
  volume    = {2784},
  number    = {1},
  pages     = {012026},
  doi       = {10.1088/1742-6596/2784/1/012026},
  url       = {https://doi.org/10.1088/1742-6596/2784/1/012026}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications

  • soft gripper
  • hyper-redundant robots
  • bio-inspired robotics
  • pneumatic actuation
  • helical deformation
  • kinematic redundancy
  • degrees of freedom
  • soft materials

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Sanyal, S., Shukla, A., Pinjan, H. S., Tailor, P., Kumar, P. P., Suman, S., & Bhargav, S. K. (2024). Pneumatically Operated Tendril-based Soft Hyper-Redundant Robotic Gripper. Journal of Physics Conference Series, 2784(1), 012026. https://doi.org/10.1088/1742-6596/2784/1/012026

How many times has this paper been cited?

0 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Journal of Physics Conference Series: sign in and open the full text from this page.

Who wrote this paper?

Shubhashis Sanyal, Anuj Shukla, Hrishi Sharad Pinjan, Piyush Tailor, Pyla Pavan Kumar, Saurav Suman, Surjeet Kumar Bhargav.

What is the DOI of this paper?

10.1088/1742-6596/2784/1/012026, permanently at https://doi.org/10.1088/1742-6596/2784/1/012026. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.