Journal article · 1991 · Open access
Optical Coherence Tomography
Science, 254(5035), 1178–1181 · Published 22 November 1991 · DOI 10.1126/science.1957169
In brief
“Optical Coherence Tomography” is a 1991 journal article by David Huang and 10 co-authors, published in Science. OpenAlex counts 14,253 citations as of 16 November 2026, which puts it in the top 1% of works published in 1991 by citations. It is open access: the full text is free to read at Europe PMC (PubMed Central).
- Citations
- 14,253
- Most cited in
- 2017 (716)
- Field-weighted impact
- 9.79
- References
- 40
- Authors
- 11
Abstract
A technique called optical coherence tomography (OCT) has been developed for noninvasive cross-sectional imaging in biological systems. OCT uses low-coherence interferometry to produce a two-dimensional image of optical scattering from internal tissue microstructures in a way that is analogous to ultrasonic pulse-echo imaging. OCT has longitudinal and lateral spatial resolutions of a few micrometers and can detect reflected signals as small as approximately 10(-10) of the incident optical power. Tomographic imaging is demonstrated in vitro in the peripapillary area of the retina and in the coronary artery, two clinically relevant examples that are representative of transparent and turbid media, respectively.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K. W., Puliafito, C. A., & Fujimoto, J. G. (1991). Optical Coherence Tomography. Science, 254(5035), 1178–1181. https://doi.org/10.1126/science.1957169
MLA 9
Huang, David, et al. “Optical Coherence Tomography.” Science, vol. 254, no. 5035, 1991, pp. 1178–1181. https://doi.org/10.1126/science.1957169.
Chicago
Huang, David, Eric A. Swanson, Charles P. Lin, Joel S. Schuman, William G. Stinson, Warren Chang, Michael R. Hee, et al. 1991. “Optical Coherence Tomography.” Science 254 (5035): 1178–1181. https://doi.org/10.1126/science.1957169.
Harvard
Huang, D. et al. (1991) ‘Optical Coherence Tomography’, Science, 254(5035), pp. 1178–1181. doi:10.1126/science.1957169.
IEEE
D. Huang et al., “Optical Coherence Tomography,” Science, vol. 254, no. 5035, pp. 1178–1181, 1991, doi: 10.1126/science.1957169.
BibTeX
@article{huang1991optical,
title = {{Optical Coherence Tomography}},
author = {Huang, David and Swanson, Eric A. and Lin, Charles P. and Schuman, Joel S. and Stinson, William G. and Chang, Warren and Hee, Michael R. and Flotte, Thomas and Gregory, Kenton W. and Puliafito, Carmen A. and Fujimoto, James G.},
journal = {Science},
year = {1991},
volume = {254},
number = {5035},
pages = {1178--1181},
doi = {10.1126/science.1957169},
url = {https://doi.org/10.1126/science.1957169}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2017 | 716 | |
| 2018 | 716 | |
| 2019 | 700 | |
| 2020 | 655 | |
| 2021 | 638 | |
| 2022 | 666 | |
| 2023 | 576 | |
| 2024 | 554 | |
| 2025 | 609 | |
| 2026 | 528 |
Its field-weighted citation impact is 9.79: it has been cited 9.79 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- optical coherence tomography
- low-coherence interferometry
- cross-sectional imaging
- tissue microstructure
- light scattering
- peripapillary retina
- coronary artery imaging
- non-invasive imaging
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K. W., Puliafito, C. A., & Fujimoto, J. G. (1991). Optical Coherence Tomography. Science, 254(5035), 1178–1181. https://doi.org/10.1126/science.1957169
How many times has this paper been cited?
14,253 times, according to OpenAlex on 16 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Europe PMC (PubMed Central): sign in and open the full text from this page.
Who wrote this paper?
David Huang, Eric A. Swanson, Charles P. Lin, Joel S. Schuman, William G. Stinson, Warren Chang, Michael R. Hee, Thomas Flotte, Kenton W. Gregory, Carmen A. Puliafito, James G. Fujimoto.
What is the DOI of this paper?
10.1126/science.1957169, permanently at https://doi.org/10.1126/science.1957169. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 16 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.