Journal article · 2025 · Open access
Novel 3D printed resin crown versus prefabricated zirconia crown for restoring pulpotomized primary molars: in vitro evaluation of fracture resistance and marginal gap
European Archives of Paediatric Dentistry, 26(5), 931–940 · Published 2 May 2025 · DOI 10.1007/s40368-025-01038-1
In brief
“Novel 3D printed resin crown versus prefabricated zirconia crown for restoring pulpotomized primary molars: in vitro evaluation of fracture resistance and marginal gap” is a 2025 journal article by E I A Elnagar and 2 co-authors, published in European Archives of Paediatric Dentistry. OpenAlex counts 9 citations as of 18 November 2026. It is open access under a CC BY licence: the full text is free to read at European Archives of Paediatric Dentistry.
- Citations
- 9
- Most cited in
- 2026 (8)
- Field-weighted impact
- 6.34
- References
- 36
- Authors
- 3
Abstract
AIM: This in vitro study aimed to evaluate the marginal gap and fracture resistance of 3D printing microfilled hybrid resin crowns in comparison to prefabricated zirconia crowns on pulpotomized primary teeth. MATERIALS AND METHODS: Twenty primary molars were selected for the study and randomly divided into two groups (n = 10). Group1 received 3D printed microfilled hybrid resin crowns; Group 2 received prefabricated zirconia crowns. To simulate 6 months of oral conditions, thermodynamic cycling was performed, and the marginal gap was measured using a stereomicroscope with digital camera at 40 × magnification. For each sample, eight points along the margins for each axial surface were captured. The fracture resistance of each group was assessed by applying increasing load till crown fracture using a computer-controlled universal testing machine. Data were tested for normality using the Shapiro-Wilk test. Data were analyzed using an independent t test. A significant level was set at P < 0.05. RESULTS: Regarding fracture resistance, 3D printed crowns group had statistically significant higher mean values than the prefabricated zirconia crowns group; the values were 1235.97 ± 412.12 N and 576.56 ± 221.53 N, respectively (P < 0.001). However, there was no significant difference in the marginal gap between the two types of crowns with average 32.00 ± 7.54 for 3D printed crowns and average 34.14 ± 9.79 for zirconia crowns (P < 0.001). CONCLUSION: 3D printed microfilled hybrid resin crowns could be a suitable esthetic alternative for restoring pulp-treated primary molars. It is possible to provide an additional esthetic solution for the parents/children to satisfy the need for esthetic restoration of primary molars. CLINICAL TRIAL: Not applicable (in vitro study).
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Elnagar, E. I. A., Allam, G. G., & Khattab, N. M. A. (2025). Novel 3D printed resin crown versus prefabricated zirconia crown for restoring pulpotomized primary molars: in vitro evaluation of fracture resistance and marginal gap. European Archives of Paediatric Dentistry, 26(5), 931–940. https://doi.org/10.1007/s40368-025-01038-1
MLA 9
Elnagar, E I A, et al. “Novel 3D printed resin crown versus prefabricated zirconia crown for restoring pulpotomized primary molars: in vitro evaluation of fracture resistance and marginal gap.” European Archives of Paediatric Dentistry, vol. 26, no. 5, 2025, pp. 931–940. https://doi.org/10.1007/s40368-025-01038-1.
Chicago
Elnagar, E I A, Gehan Gaber Allam, and Nagwa Mohammed Ali Khattab. 2025. “Novel 3D printed resin crown versus prefabricated zirconia crown for restoring pulpotomized primary molars: in vitro evaluation of fracture resistance and marginal gap.” European Archives of Paediatric Dentistry 26 (5): 931–940. https://doi.org/10.1007/s40368-025-01038-1.
Harvard
Elnagar, E. I. A., Allam, G. G. and Khattab, N. M. A. (2025) ‘Novel 3D printed resin crown versus prefabricated zirconia crown for restoring pulpotomized primary molars: in vitro evaluation of fracture resistance and marginal gap’, European Archives of Paediatric Dentistry, 26(5), pp. 931–940. doi:10.1007/s40368-025-01038-1.
IEEE
E. I. A. Elnagar, G. G. Allam, and N. M. A. Khattab, “Novel 3D printed resin crown versus prefabricated zirconia crown for restoring pulpotomized primary molars: in vitro evaluation of fracture resistance and marginal gap,” European Archives of Paediatric Dentistry, vol. 26, no. 5, pp. 931–940, 2025, doi: 10.1007/s40368-025-01038-1.
BibTeX
@article{elnagar2025novel,
title = {{Novel 3D printed resin crown versus prefabricated zirconia crown for restoring pulpotomized primary molars: in vitro evaluation of fracture resistance and marginal gap}},
author = {Elnagar, E I A and Allam, Gehan Gaber and Khattab, Nagwa Mohammed Ali},
journal = {European Archives of Paediatric Dentistry},
year = {2025},
volume = {26},
number = {5},
pages = {931--940},
doi = {10.1007/s40368-025-01038-1},
url = {https://doi.org/10.1007/s40368-025-01038-1}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Health Sciences › Dentistry › General Dentistry › Dental materials and restorations
- 3D-printed crowns
- zirconia crowns
- fracture resistance
- marginal gap
- marginal adaptation
- esthetic restorations
- primary molars
- thermomechanical cycling
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Elnagar, E. I. A., Allam, G. G., & Khattab, N. M. A. (2025). Novel 3D printed resin crown versus prefabricated zirconia crown for restoring pulpotomized primary molars: in vitro evaluation of fracture resistance and marginal gap. European Archives of Paediatric Dentistry, 26(5), 931–940. https://doi.org/10.1007/s40368-025-01038-1
How many times has this paper been cited?
9 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at European Archives of Paediatric Dentistry: sign in and open the PDF from this page.
Who wrote this paper?
E I A Elnagar, Gehan Gaber Allam, Nagwa Mohammed Ali Khattab.
What is the DOI of this paper?
10.1007/s40368-025-01038-1, permanently at https://doi.org/10.1007/s40368-025-01038-1. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.