Journal article · 2022 · Open access
NOISE INTENSITY, BLOOD PRESSURE, AND PULSE RATE IN TEXTILE INDUSTRY WORKERS
PLACENTUM Jurnal Ilmiah Kesehatan dan Aplikasinya, 10(1), 73 · Published 28 February 2022 · DOI 10.20961/placentum.v10i1.53146
In brief
“NOISE INTENSITY, BLOOD PRESSURE, AND PULSE RATE IN TEXTILE INDUSTRY WORKERS” is a 2022 journal article by Bachtiar Chahyadhi and 4 co-authors, published in PLACENTUM Jurnal Ilmiah Kesehatan dan Aplikasinya. OpenAlex counts 6 citations as of 19 November 2026. It is open access under a CC BY-SA licence: the full text is free to read at PLACENTUM Jurnal Ilmiah Kesehatan dan Aplikasinya.
- Citations
- 6
- Most cited in
- 2025 (3)
- Field-weighted impact
- 0.62
- References
- 29
- Authors
- 5
Abstract
Background: Noise intensity that exceeds Threshold Limit Value (TLV) can give impacts on non-auditory on the workers in a factory, in the form of an increase in blood pressure and pulse rate. Currently, health problems due to noise have caused the company’s total loss to reach 300 billion dollars due to absenteeism rate, decreased productivity, and treatment for occupational diseases. Research in Indonesia, especially the textile industry in the city of Surakarta, shows that noise from weaving machines with an intensity above 100 dBA affects blood pressure and pulse rate. This research was conducted at textile industry in Surakarta, one of the largest textile companies in Surakarta where the company has not been able to overcome the problem of noise intensity that exceeds the TLV which has the potential to cause blood pressure and pulse disturbances, and even decreased hearing function. This study aims to determine the relationship between noise intensity with blood pressure and pulse rate in textile industry workers. Method: This research is a correlation study, which is connecting the measurement variables of noise intensity with blood pressure and pulse rate. The sample in this study were 30 female workers in the weaving division who met the inclusion and exclusion criteria. The instruments used in measuring noise were sound level meters and sphygmomanometers. Data analysis used the Pearson correlation test to determine the relationship between noise intensity with blood pressure and pulse rate disturbances. Result: The study showed significant correlation between noise intensity and pulse rate with a p value of 0.029, but noise intensity with blood pressure disturbances does not correlate, with a p value of 0.443. Conclusion: There is a relationship between noise intensity and pulse rate of the workers in a factory.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Chahyadhi, B., Widjanarti, M. P., Ada, Y. R., Suratna, F. S. N., & Wijayanti, R. (2022). NOISE INTENSITY, BLOOD PRESSURE, AND PULSE RATE IN TEXTILE INDUSTRY WORKERS. PLACENTUM Jurnal Ilmiah Kesehatan dan Aplikasinya, 10(1), 73. https://doi.org/10.20961/placentum.v10i1.53146
MLA 9
Chahyadhi, Bachtiar, et al. “NOISE INTENSITY, BLOOD PRESSURE, AND PULSE RATE IN TEXTILE INDUSTRY WORKERS.” PLACENTUM Jurnal Ilmiah Kesehatan dan Aplikasinya, vol. 10, no. 1, 2022, p. 73. https://doi.org/10.20961/placentum.v10i1.53146.
Chicago
Chahyadhi, Bachtiar, Maria Paskanita Widjanarti, Yeremia Rante Ada, Farhana Syahrotun Nisa Suratna, and Reni Wijayanti. 2022. “NOISE INTENSITY, BLOOD PRESSURE, AND PULSE RATE IN TEXTILE INDUSTRY WORKERS.” PLACENTUM Jurnal Ilmiah Kesehatan dan Aplikasinya 10 (1): 73. https://doi.org/10.20961/placentum.v10i1.53146.
Harvard
Chahyadhi, B. et al. (2022) ‘NOISE INTENSITY, BLOOD PRESSURE, AND PULSE RATE IN TEXTILE INDUSTRY WORKERS’, PLACENTUM Jurnal Ilmiah Kesehatan dan Aplikasinya, 10(1), p. 73. doi:10.20961/placentum.v10i1.53146.
IEEE
B. Chahyadhi, M. P. Widjanarti, Y. R. Ada, F. S. N. Suratna, and R. Wijayanti, “NOISE INTENSITY, BLOOD PRESSURE, AND PULSE RATE IN TEXTILE INDUSTRY WORKERS,” PLACENTUM Jurnal Ilmiah Kesehatan dan Aplikasinya, vol. 10, no. 1, p. 73, 2022, doi: 10.20961/placentum.v10i1.53146.
BibTeX
@article{chahyadhi2022noise,
title = {{NOISE INTENSITY, BLOOD PRESSURE, AND PULSE RATE IN TEXTILE INDUSTRY WORKERS}},
author = {Chahyadhi, Bachtiar and Widjanarti, Maria Paskanita and Ada, Yeremia Rante and Suratna, Farhana Syahrotun Nisa and Wijayanti, Reni},
journal = {PLACENTUM Jurnal Ilmiah Kesehatan dan Aplikasinya},
year = {2022},
volume = {10},
number = {1},
pages = {73},
doi = {10.20961/placentum.v10i1.53146},
url = {https://doi.org/10.20961/placentum.v10i1.53146}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2023 | 1 | |
| 2024 | 2 | |
| 2025 | 3 |
Its field-weighted citation impact is 0.62: it has been cited 0.62 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Physics and Astronomy › Acoustics and Ultrasonics › Noise Effects and Management
- occupational noise exposure
- noise intensity
- blood pressure
- pulse rate
- textile workers
- loom
- non-auditory effects of noise
- female workers
Work with this paper
Most-cited papers in Physics and Astronomy
- Generalized Gradient Approximation Made SimpleJohn P. Perdew, Kieron Burke, Matthias Ernzerhof · Physical Review Letters · 1996 · 217,345 citations
- Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis setGeorg Kresse, Jürgen Furthmüller · Physical review. B, Condensed matter · 1996 · 125,164 citations
- Density-functional thermochemistry. III. The role of exact exchangeAxel D. Becke · The Journal of Chemical Physics · 1993 · 104,772 citations
- Development of the Colle-Salvetti correlation-energy formula into a functional of the electron densityChengteh Lee, Weitao Yang, Robert G. Parr · Physical review. B, Condensed matter · 1988 · 101,730 citations
- Projector augmented-wave methodPeter E. Blöchl · Physical review. B, Condensed matter · 1994 · 93,520 citations
Questions about this paper
How do I cite this paper in APA style?
Chahyadhi, B., Widjanarti, M. P., Ada, Y. R., Suratna, F. S. N., & Wijayanti, R. (2022). NOISE INTENSITY, BLOOD PRESSURE, AND PULSE RATE IN TEXTILE INDUSTRY WORKERS. PLACENTUM Jurnal Ilmiah Kesehatan dan Aplikasinya, 10(1), 73. https://doi.org/10.20961/placentum.v10i1.53146
How many times has this paper been cited?
6 times, according to OpenAlex on 19 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at PLACENTUM Jurnal Ilmiah Kesehatan dan Aplikasinya: sign in and open the PDF from this page.
Who wrote this paper?
Bachtiar Chahyadhi, Maria Paskanita Widjanarti, Yeremia Rante Ada, Farhana Syahrotun Nisa Suratna, Reni Wijayanti.
What is the DOI of this paper?
10.20961/placentum.v10i1.53146, permanently at https://doi.org/10.20961/placentum.v10i1.53146. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 19 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.