Report · 1995 · Open access

New electrolyte systems for capillary zone electrophoresis of metal cations and non-ionic organic compounds

IA (United States) Ames Lab., Youchun Shi, USDOE

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Published 19 June 1995 · DOI 10.2172/108134

Open full textView at the publisherCite this paper

In brief

“New electrolyte systems for capillary zone electrophoresis of metal cations and non-ionic organic compounds” is a 1995 report by IA (United States) Ames Lab. and 2 co-authors, published in OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information). OpenAlex counts 0 citations as of 20 November 2026. It is open access: the full text is free to read at OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information).

Citations
0
References
1
Authors
3

Abstract

Excellent separations of metal ions can be obtained very quickly by capillary electrophoresis provided a weak complexing reagent is incorporated into the electrolyte to alter the effective mobilities of the sample ions. Indirect photometric detection is possible by also adding a UV-sensitive ion to the electrolyte. Separations are described using phthalate, tartrate, lactate or hydroxyisobutyrate as the complexing reagent. A separation of twenty-seven metal ions was achieved in only 6 min using a lactate system. A mechanism for the separation of lanthanides is proposed for the hydroxyisobutyrate system.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Lab., I. S. A., Shi, Y., & USDOE. (1995). New electrolyte systems for capillary zone electrophoresis of metal cations and non-ionic organic compounds. OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information). https://doi.org/10.2172/108134

MLA 9

Lab., IA (United States) Ames, et al. “New electrolyte systems for capillary zone electrophoresis of metal cations and non-ionic organic compounds.” OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information), 1995. https://doi.org/10.2172/108134.

Chicago

Lab., IA (United States) Ames, Youchun Shi, and USDOE. 1995. “New electrolyte systems for capillary zone electrophoresis of metal cations and non-ionic organic compounds.” OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information). https://doi.org/10.2172/108134.

Harvard

Lab., I. S. A., Shi, Y. and USDOE (1995) ‘New electrolyte systems for capillary zone electrophoresis of metal cations and non-ionic organic compounds’, OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information). doi:10.2172/108134.

IEEE

I. S. A. Lab., Y. Shi, and USDOE, “New electrolyte systems for capillary zone electrophoresis of metal cations and non-ionic organic compounds,” OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information), 1995, doi: 10.2172/108134.

BibTeX

@article{lab1995electrolyte,
  title     = {{New electrolyte systems for capillary zone electrophoresis of metal cations and non-ionic organic compounds}},
  author    = {Lab., IA (United States) Ames and Shi, Youchun and USDOE},
  journal   = {OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)},
  year      = {1995},
  doi       = {10.2172/108134},
  url       = {https://doi.org/10.2172/108134}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications

  • capillary zone electrophoresis
  • metal cations
  • complexing reagents
  • electrolyte systems
  • metal ion separation
  • indirect photometric detection
  • phthalates
  • tartrate

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Lab., I. S. A., Shi, Y., & USDOE. (1995). New electrolyte systems for capillary zone electrophoresis of metal cations and non-ionic organic compounds. OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information). https://doi.org/10.2172/108134

How many times has this paper been cited?

0 times, according to OpenAlex on 20 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information): sign in and open the full text from this page.

Who wrote this paper?

IA (United States) Ames Lab., Youchun Shi, USDOE.

What is the DOI of this paper?

10.2172/108134, permanently at https://doi.org/10.2172/108134. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 20 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.