Journal article · 2005

Multivariate Statistical Analysis of Concatenated Time-of-Flight Secondary Ion Mass Spectrometry Spectral Images. Complete Description of the Sample with One Analysis

Vincent S. Smentkowski, Michael R. Keenan, James Anthony Ohlhausen, Paul G. Kotula

Analytical Chemistry, 77(5), 1530–1536 · Published 26 January 2005 · DOI 10.1021/ac048468y

View at the publisherCite this paper

In brief

“Multivariate Statistical Analysis of Concatenated Time-of-Flight Secondary Ion Mass Spectrometry Spectral Images. Complete Description of the Sample with One Analysis” is a 2005 journal article by Vincent S. Smentkowski and 3 co-authors, published in Analytical Chemistry. OpenAlex counts 40 citations as of 23 November 2026. The publisher's version is not open access, and OpenAlex records no free legal copy.

Citations
40
Most cited in
2014 (3)
Field-weighted impact
4.63
References
8
Authors
4

Abstract

Time-of-flight secondary ion mass spectrometry (TOF-SIMS) instruments are capable of saving an entire mass spectrum at each pixel of an image, allowing for retrospective analysis of masses that were not selected for analysis during data collection. These TOF-SIMS spectral images contain a wealth of information, but few tools are available to assist the analyst in… Read the full abstract at the publisher.

Excerpt. This paper is not open access.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Smentkowski, V. S., Keenan, M. R., Ohlhausen, J. A., & Kotula, P. G. (2005). Multivariate Statistical Analysis of Concatenated Time-of-Flight Secondary Ion Mass Spectrometry Spectral Images. Complete Description of the Sample with One Analysis. Analytical Chemistry, 77(5), 1530–1536. https://doi.org/10.1021/ac048468y

MLA 9

Smentkowski, Vincent S., et al. “Multivariate Statistical Analysis of Concatenated Time-of-Flight Secondary Ion Mass Spectrometry Spectral Images. Complete Description of the Sample with One Analysis.” Analytical Chemistry, vol. 77, no. 5, 2005, pp. 1530–1536. https://doi.org/10.1021/ac048468y.

Chicago

Smentkowski, Vincent S., Michael R. Keenan, James Anthony Ohlhausen, and Paul G. Kotula. 2005. “Multivariate Statistical Analysis of Concatenated Time-of-Flight Secondary Ion Mass Spectrometry Spectral Images. Complete Description of the Sample with One Analysis.” Analytical Chemistry 77 (5): 1530–1536. https://doi.org/10.1021/ac048468y.

Harvard

Smentkowski, V. S. et al. (2005) ‘Multivariate Statistical Analysis of Concatenated Time-of-Flight Secondary Ion Mass Spectrometry Spectral Images. Complete Description of the Sample with One Analysis’, Analytical Chemistry, 77(5), pp. 1530–1536. doi:10.1021/ac048468y.

IEEE

V. S. Smentkowski, M. R. Keenan, J. A. Ohlhausen, and P. G. Kotula, “Multivariate Statistical Analysis of Concatenated Time-of-Flight Secondary Ion Mass Spectrometry Spectral Images. Complete Description of the Sample with One Analysis,” Analytical Chemistry, vol. 77, no. 5, pp. 1530–1536, 2005, doi: 10.1021/ac048468y.

BibTeX

@article{smentkowski2005multivariate,
  title     = {{Multivariate Statistical Analysis of Concatenated Time-of-Flight Secondary Ion Mass Spectrometry Spectral Images. Complete Description of the Sample with One Analysis}},
  author    = {Smentkowski, Vincent S. and Keenan, Michael R. and Ohlhausen, James Anthony and Kotula, Paul G.},
  journal   = {Analytical Chemistry},
  year      = {2005},
  volume    = {77},
  number    = {5},
  pages     = {1530--1536},
  doi       = {10.1021/ac048468y},
  url       = {https://doi.org/10.1021/ac048468y}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201322
201433
201511
201622
201711
201811
201911
202022
202411
202511

Its field-weighted citation impact is 4.63: it has been cited 4.63 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Materials Science › Surfaces, Coatings and Films › Ion-surface interactions and analysis

  • time-of-flight secondary ion mass spectrometry
  • multivariate analysis

Work with this paper

Most-cited papers in Materials Science

All highly cited Materials Science papers

Questions about this paper

How do I cite this paper in APA style?

Smentkowski, V. S., Keenan, M. R., Ohlhausen, J. A., & Kotula, P. G. (2005). Multivariate Statistical Analysis of Concatenated Time-of-Flight Secondary Ion Mass Spectrometry Spectral Images. Complete Description of the Sample with One Analysis. Analytical Chemistry, 77(5), 1530–1536. https://doi.org/10.1021/ac048468y

How many times has this paper been cited?

40 times, according to OpenAlex on 23 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.

Who wrote this paper?

Vincent S. Smentkowski, Michael R. Keenan, James Anthony Ohlhausen, Paul G. Kotula.

What is the DOI of this paper?

10.1021/ac048468y, permanently at https://doi.org/10.1021/ac048468y. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 23 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.