Conference paper · 2017 · Open access

Multi-modal Sensory Feedback System for Upper Limb Amputees

Huaiqi Huang, Tao Li, Claudio E. Bruschini, Christian Enz, Jörn Justiz, Christian Antfolk, Volker M. Koch

IEEE International Conference on New Generation of Circuits and Systems (NGCAS), 193–196 · Published 1 September 2017 · DOI 10.1109/ngcas.2017.62

Open full textView at the publisherCite this paper

In brief

“Multi-modal Sensory Feedback System for Upper Limb Amputees” is a 2017 conference paper by Huaiqi Huang and 6 co-authors, published in IEEE International Conference on New Generation of Circuits and Systems (NGCAS). OpenAlex counts 20 citations as of 22 November 2026. It is open access: the full text is free to read at Infoscience (Ecole Polytechnique Fédérale de Lausanne).

Citations
20
Most cited in
2021 (4)
Field-weighted impact
1.99
References
15
Authors
7

Abstract

Providing sensory feedback for myoelectric prosthetic users can not only increase the manipulation ability but can also introduce a feeling of embodiment. Previous research has demonstrated the feasibility of providing mechanotactile or vibrotactile feedback on the remaining stumps of amputees. To improve the recognition rate and reduce mental work load when identifying stimulation patterns, we propose a multi-modal sensory feedback system for upper limb amputees. The system consists of five tactile sensors, Bluetooth wireless communication modules, and a custom-designed multi-modal stimulation array incorporating vibrotactile and mechanotactile stimulation modalities. Three amputees (two with phantom map and one without phantom map) tested the system in localization and stimulation intensity identification tasks. Experimental results show the effectiveness of the multi-modal stimulation compared with single modal stimulation. To the best of our knowledge, this is the first attempt to combine vibrotactile and mechanotactile stimulation in a sensory feedback system for upper limb amputees.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Huang, H., Li, T., Bruschini, C. E., Enz, C., Justiz, J., Antfolk, C., & Koch, V. M. (2017). Multi-modal Sensory Feedback System for Upper Limb Amputees. IEEE International Conference on New Generation of Circuits and Systems (NGCAS), 193–196. https://doi.org/10.1109/ngcas.2017.62

MLA 9

Huang, Huaiqi, et al. “Multi-modal Sensory Feedback System for Upper Limb Amputees.” IEEE International Conference on New Generation of Circuits and Systems (NGCAS), 2017, pp. 193–196. https://doi.org/10.1109/ngcas.2017.62.

Chicago

Huang, Huaiqi, Tao Li, Claudio E. Bruschini, Christian Enz, Jörn Justiz, Christian Antfolk, and Volker M. Koch. 2017. “Multi-modal Sensory Feedback System for Upper Limb Amputees.” IEEE International Conference on New Generation of Circuits and Systems (NGCAS): 193–196. https://doi.org/10.1109/ngcas.2017.62.

Harvard

Huang, H. et al. (2017) ‘Multi-modal Sensory Feedback System for Upper Limb Amputees’, IEEE International Conference on New Generation of Circuits and Systems (NGCAS), pp. 193–196. doi:10.1109/ngcas.2017.62.

IEEE

H. Huang et al., “Multi-modal Sensory Feedback System for Upper Limb Amputees,” IEEE International Conference on New Generation of Circuits and Systems (NGCAS), pp. 193–196, 2017, doi: 10.1109/ngcas.2017.62.

BibTeX

@inproceedings{huang2017multi,
  title     = {{Multi-modal Sensory Feedback System for Upper Limb Amputees}},
  author    = {Huang, Huaiqi and Li, Tao and Bruschini, Claudio E. and Enz, Christian and Justiz, Jörn and Antfolk, Christian and Koch, Volker M.},
  booktitle = {IEEE International Conference on New Generation of Circuits and Systems (NGCAS)},
  year      = {2017},
  pages     = {193--196},
  doi       = {10.1109/ngcas.2017.62},
  url       = {https://doi.org/10.1109/ngcas.2017.62}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201811
201922
202022
202144
202222
202344
202411
202522
202622

Its field-weighted citation impact is 1.99: it has been cited 1.99 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies

  • sensory feedback
  • upper limb amputees
  • myoelectric prosthesis
  • vibrotactile stimulation
  • Bluetooth communication
  • tactile sensors
  • embodiment

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Huang, H., Li, T., Bruschini, C. E., Enz, C., Justiz, J., Antfolk, C., & Koch, V. M. (2017). Multi-modal Sensory Feedback System for Upper Limb Amputees. IEEE International Conference on New Generation of Circuits and Systems (NGCAS), 193–196. https://doi.org/10.1109/ngcas.2017.62

How many times has this paper been cited?

20 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Infoscience (Ecole Polytechnique Fédérale de Lausanne): sign in and open the full text from this page.

Who wrote this paper?

Huaiqi Huang, Tao Li, Claudio E. Bruschini, Christian Enz, Jörn Justiz, Christian Antfolk, Volker M. Koch.

What is the DOI of this paper?

10.1109/ngcas.2017.62, permanently at https://doi.org/10.1109/ngcas.2017.62. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.