Dissertation · 2010 · Open access

Modified Carbon Paste Electrodes and Polyaniline Electrodes: Study of their interaction with copper and chromium aquous metallic ions by Differential Pulse Voltammetry

R Barbosa Lima

LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Published 11 May 2010

Open full textCite this paper

In brief

“Modified Carbon Paste Electrodes and Polyaniline Electrodes: Study of their interaction with copper and chromium aquous metallic ions by Differential Pulse Voltammetry” is a 2010 dissertation by R Barbosa Lima, published in LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas). OpenAlex counts 0 citations as of 22 November 2026. It is open access: the full text is free to read at LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas).

Citations
0
Authors
1

Abstract

The electrochemical sensors to measure metallic ions in water and waste water are among the most important areas of research nowadays. The environmental control and monitoring chalenges that stimulated the aim of this work are tanification for industrial leather finishing and cuprous and cupric organic and inorganic fungicides. The features for characterization of metallic ions in water, specially for Cu2+ e Cr6+ and the properties of Humic Acid extracted from Turfe, or Turf Humic Acid (AHT) and Lignossufonic Acid, or Sulfonated Lignin (LigS), were exposed, as well as the properties and synthesis methods for Polyaniline (PAni). The following electrodes were prepaired and used on this work: The carbon paste modified electrodes, prepared with AHT extracted at Mogi river estuarine region near Luis Antonio city São Paulo State, Brazil. Another carbon paste was prepared for comparison with LigS obtained from pinus pulp processing and treatment by Melbar Company (Parana State, Brazil). The working electrode that used PAni films were prepared by electrochemical synthesis onto graphite rods. The cyclic voltammetry technique was used to synthesize PAni in acid media of 0.5 to 1.0 mol L-1 H2SO4 (PAni-H2SO4) and scanning speed of v=20mVs-1, v=50mVs-1. The same procedure was used to synthesize the PAni films, in the same acid media, and the solution has 0.05 mg L-1 of dispersed LigS (PAni-H2SO4+LigS). These electrodes had their Differential Pulse Voltammetry (DPV) current peak response studied with Factorial Planning. The most important results were compared by linear response, sensibility, limit of detection (LD) and repetability. The best electrodes for Cr6+ ions was PAni-H2SO4+LigS with a sensibility of 10.3A/10-7molL-1, 2.87% of repeatability, 5.6% of reproducibility and LD = 1.96 10-8 mol L-1. For copper ions the Carbon Paste modified with LigS was the best electrode wich has a sensibility of 9.5 A/10-7mol L-1, 1.5% of repeatability, reproducibility of 3.5% and LD = 4.9 10-8 mol L-1. Both electrodes have, each other, a linear calibration curve for Ip response that includes the limits of concentration for brazilian s environmental laws (CONAMA 397/april 2008), by DPV method, obtained on acetate buffer, pH=4,5, pulse height zE=75 mV, Ed = -0.35 V and scanning speed v= 20mVs-1.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Lima, R. B. (2010). Modified Carbon Paste Electrodes and Polyaniline Electrodes: Study of their interaction with copper and chromium aquous metallic ions by Differential Pulse Voltammetry. LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas). https://repositorio.ufscar.br/handle/20.500.14289/6165

MLA 9

Lima, R Barbosa. “Modified Carbon Paste Electrodes and Polyaniline Electrodes: Study of their interaction with copper and chromium aquous metallic ions by Differential Pulse Voltammetry.” LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas), 2010. https://repositorio.ufscar.br/handle/20.500.14289/6165.

Chicago

Lima, R Barbosa. 2010. “Modified Carbon Paste Electrodes and Polyaniline Electrodes: Study of their interaction with copper and chromium aquous metallic ions by Differential Pulse Voltammetry.” LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas). https://repositorio.ufscar.br/handle/20.500.14289/6165.

Harvard

Lima, R. B. (2010) ‘Modified Carbon Paste Electrodes and Polyaniline Electrodes: Study of their interaction with copper and chromium aquous metallic ions by Differential Pulse Voltammetry’, LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas). Available at: https://repositorio.ufscar.br/handle/20.500.14289/6165.

IEEE

R. B. Lima, “Modified Carbon Paste Electrodes and Polyaniline Electrodes: Study of their interaction with copper and chromium aquous metallic ions by Differential Pulse Voltammetry,” LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas), 2010.

BibTeX

@phdthesis{lima2010modified,
  title     = {{Modified Carbon Paste Electrodes and Polyaniline Electrodes: Study of their interaction with copper and chromium aquous metallic ions by Differential Pulse Voltammetry}},
  author    = {Lima, R Barbosa},
  year      = {2010},
  url       = {https://repositorio.ufscar.br/handle/20.500.14289/6165}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications

  • carbon paste electrode
  • copper ion detection
  • chromium ion detection
  • electrochemical sensor
  • lignosulfonate
  • humic acid
  • electropolymerization
  • differential pulse voltammetry

Work with this paper

Most-cited papers in Chemistry

All highly cited Chemistry papers

Questions about this paper

How do I cite this paper in APA style?

Lima, R. B. (2010). Modified Carbon Paste Electrodes and Polyaniline Electrodes: Study of their interaction with copper and chromium aquous metallic ions by Differential Pulse Voltammetry. LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas). https://repositorio.ufscar.br/handle/20.500.14289/6165

How many times has this paper been cited?

0 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas): sign in and open the full text from this page.

Who wrote this paper?

R Barbosa Lima.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.