Conference paper · 2006

MODELING OF A NEW SMA MICROACTUATOR FOR ACTIVE ENDOSCOPY APPLICATIONS

Joël Abadie, Nicolas Chaillet, Ch. Lexcellent

IFAC Proceedings Volumes, 39(3), 161–166 · Published 1 January 2006 · DOI 10.3182/20060517-3-fr-2903.00097

View at the publisherCite this paper

In brief

“MODELING OF A NEW SMA MICROACTUATOR FOR ACTIVE ENDOSCOPY APPLICATIONS” is a 2006 conference paper by Joël Abadie and 2 co-authors, published in IFAC Proceedings Volumes. OpenAlex counts 3 citations as of 22 November 2026. The publisher's version is not open access, and OpenAlex records no free legal copy.

Citations
3
Most cited in
2016 (1)
References
10
Authors
3

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Abadie, J., Chaillet, N., & Lexcellent, C. (2006). MODELING OF A NEW SMA MICROACTUATOR FOR ACTIVE ENDOSCOPY APPLICATIONS. IFAC Proceedings Volumes, 39(3), 161–166. https://doi.org/10.3182/20060517-3-fr-2903.00097

MLA 9

Abadie, Joël, et al. “MODELING OF A NEW SMA MICROACTUATOR FOR ACTIVE ENDOSCOPY APPLICATIONS.” IFAC Proceedings Volumes, vol. 39, no. 3, 2006, pp. 161–166. https://doi.org/10.3182/20060517-3-fr-2903.00097.

Chicago

Abadie, Joël, Nicolas Chaillet, and Ch. Lexcellent. 2006. “MODELING OF A NEW SMA MICROACTUATOR FOR ACTIVE ENDOSCOPY APPLICATIONS.” IFAC Proceedings Volumes 39 (3): 161–166. https://doi.org/10.3182/20060517-3-fr-2903.00097.

Harvard

Abadie, J., Chaillet, N. and Lexcellent, C. (2006) ‘MODELING OF A NEW SMA MICROACTUATOR FOR ACTIVE ENDOSCOPY APPLICATIONS’, IFAC Proceedings Volumes, 39(3), pp. 161–166. doi:10.3182/20060517-3-fr-2903.00097.

IEEE

J. Abadie, N. Chaillet, and C. Lexcellent, “MODELING OF A NEW SMA MICROACTUATOR FOR ACTIVE ENDOSCOPY APPLICATIONS,” IFAC Proceedings Volumes, vol. 39, no. 3, pp. 161–166, 2006, doi: 10.3182/20060517-3-fr-2903.00097.

BibTeX

@inproceedings{abadie2006modeling,
  title     = {{MODELING OF A NEW SMA MICROACTUATOR FOR ACTIVE ENDOSCOPY APPLICATIONS}},
  author    = {Abadie, Joël and Chaillet, Nicolas and Lexcellent, Ch.},
  booktitle = {IFAC Proceedings Volumes},
  year      = {2006},
  volume    = {39},
  number    = {3},
  pages     = {161--166},
  doi       = {10.3182/20060517-3-fr-2903.00097},
  url       = {https://doi.org/10.3182/20060517-3-fr-2903.00097}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201611
201811
202411

Topic and keywords

Physical Sciences › Materials Science › Materials Chemistry › Shape Memory Alloy Transformations

  • shape memory alloys
  • microactuators
  • Peltier effect
  • thermoelectric cooling
  • actuator design
  • response time

Work with this paper

Most-cited papers in Materials Science

All highly cited Materials Science papers

Questions about this paper

How do I cite this paper in APA style?

Abadie, J., Chaillet, N., & Lexcellent, C. (2006). MODELING OF A NEW SMA MICROACTUATOR FOR ACTIVE ENDOSCOPY APPLICATIONS. IFAC Proceedings Volumes, 39(3), 161–166. https://doi.org/10.3182/20060517-3-fr-2903.00097

How many times has this paper been cited?

3 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.

Who wrote this paper?

Joël Abadie, Nicolas Chaillet, Ch. Lexcellent.

What is the DOI of this paper?

10.3182/20060517-3-fr-2903.00097, permanently at https://doi.org/10.3182/20060517-3-fr-2903.00097. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.