Conference paper · 2008
MicroNewton Force-Controlled Manipulation of Biomaterials using a Monolithic MEMS Microgripper with Two-Axis Force Feedback
Proceedings - IEEE International Conference on Robotics and Automation/Proceedings, 3100–3105 · Published 1 May 2008 · DOI 10.1109/robot.2008.4543682
In brief
“MicroNewton Force-Controlled Manipulation of Biomaterials using a Monolithic MEMS Microgripper with Two-Axis Force Feedback” is a 2008 conference paper by Keekyoung Kim and 3 co-authors, published in Proceedings - IEEE International Conference on Robotics and Automation/Proceedings. OpenAlex counts 57 citations as of 22 November 2026. The publisher's version is not open access, and OpenAlex records no free legal copy.
- Citations
- 57
- Most cited in
- 2017 (7)
- Field-weighted impact
- 3.86
- References
- 25
- Authors
- 4
Abstract
This paper presents the first demonstration of force-controlled micrograsping at the microNewton force level. The system manipulates highly deformable biomaterials (hydrogel microcapsules and biological cells) in an aqueous environment using a MEMS-based microgripper with integrated force feedback along two axes. The microgripper integrates an electrothermal V-beam microactuator and two capacitive force sensors, one for contact… Read the full abstract at the publisher.
Excerpt. This paper is not open access.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Kim, K., Liu, X., Zhang, Y., & Sun, Y. (2008). MicroNewton Force-Controlled Manipulation of Biomaterials using a Monolithic MEMS Microgripper with Two-Axis Force Feedback. Proceedings - IEEE International Conference on Robotics and Automation/Proceedings, 3100–3105. https://doi.org/10.1109/robot.2008.4543682
MLA 9
Kim, Keekyoung, et al. “MicroNewton Force-Controlled Manipulation of Biomaterials using a Monolithic MEMS Microgripper with Two-Axis Force Feedback.” Proceedings - IEEE International Conference on Robotics and Automation/Proceedings, 2008, pp. 3100–3105. https://doi.org/10.1109/robot.2008.4543682.
Chicago
Kim, Keekyoung, Xinyu Liu, Yong Zhang, and Yu Sun. 2008. “MicroNewton Force-Controlled Manipulation of Biomaterials using a Monolithic MEMS Microgripper with Two-Axis Force Feedback.” Proceedings - IEEE International Conference on Robotics and Automation/Proceedings: 3100–3105. https://doi.org/10.1109/robot.2008.4543682.
Harvard
Kim, K. et al. (2008) ‘MicroNewton Force-Controlled Manipulation of Biomaterials using a Monolithic MEMS Microgripper with Two-Axis Force Feedback’, Proceedings - IEEE International Conference on Robotics and Automation/Proceedings, pp. 3100–3105. doi:10.1109/robot.2008.4543682.
IEEE
K. Kim, X. Liu, Y. Zhang, and Y. Sun, “MicroNewton Force-Controlled Manipulation of Biomaterials using a Monolithic MEMS Microgripper with Two-Axis Force Feedback,” Proceedings - IEEE International Conference on Robotics and Automation/Proceedings, pp. 3100–3105, 2008, doi: 10.1109/robot.2008.4543682.
BibTeX
@inproceedings{kim2008micronewton,
title = {{MicroNewton Force-Controlled Manipulation of Biomaterials using a Monolithic MEMS Microgripper with Two-Axis Force Feedback}},
author = {Kim, Keekyoung and Liu, Xinyu and Zhang, Yong and Sun, Yu},
booktitle = {Proceedings - IEEE International Conference on Robotics and Automation/Proceedings},
year = {2008},
pages = {3100--3105},
doi = {10.1109/robot.2008.4543682},
url = {https://doi.org/10.1109/robot.2008.4543682}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2017 | 7 | |
| 2018 | 3 | |
| 2019 | 3 | |
| 2020 | 2 | |
| 2021 | 3 | |
| 2022 | 2 | |
| 2023 | 1 | |
| 2024 | 1 | |
| 2025 | 1 | |
| 2026 | 1 |
Its field-weighted citation impact is 3.86: it has been cited 3.86 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- MEMS microgripper
- hydrogel microcapsules
- cell manipulation
- capacitive force sensor
- contact detection
- aqueous environment
- cell viability
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Kim, K., Liu, X., Zhang, Y., & Sun, Y. (2008). MicroNewton Force-Controlled Manipulation of Biomaterials using a Monolithic MEMS Microgripper with Two-Axis Force Feedback. Proceedings - IEEE International Conference on Robotics and Automation/Proceedings, 3100–3105. https://doi.org/10.1109/robot.2008.4543682
How many times has this paper been cited?
57 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.
Who wrote this paper?
Keekyoung Kim, Xinyu Liu, Yong Zhang, Yu Sun.
What is the DOI of this paper?
10.1109/robot.2008.4543682, permanently at https://doi.org/10.1109/robot.2008.4543682. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.