Journal article · 2013
Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+
Advanced Healthcare Materials, 3(6), 876–881 · Published 21 December 2013 · DOI 10.1002/adhm.201300541
In brief
“Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+” is a 2013 journal article by Philip R. Miller and 5 co-authors, published in Advanced Healthcare Materials. OpenAlex counts 175 citations as of 18 November 2026. The publisher's version is not open access, and OpenAlex records no free legal copy.
- Citations
- 175
- Most cited in
- 2019 (22)
- Field-weighted impact
- 3.34
- References
- 21
- Authors
- 6
Abstract
The determination of electrolytes is invaluable for point of care diagnostic applications. An ion selective transdermal microneedle sensor is demonstrated for potassium by integrating a hollow microneedle with a microfluidic chip to extract fluid through a channel towards a downstream solid-state ion-selective-electrode (ISE). 3D porous carbon and 3D porous graphene electrodes, made via interference lithography… Read the full abstract at the publisher.
Excerpt. This paper is not open access.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Miller, P. R., Xiao, X., Brener, I., Burckel, D. B., Narayan, R. J., & Polsky, R. (2013). Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+. Advanced Healthcare Materials, 3(6), 876–881. https://doi.org/10.1002/adhm.201300541
MLA 9
Miller, Philip R., et al. “Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+.” Advanced Healthcare Materials, vol. 3, no. 6, 2013, pp. 876–881. https://doi.org/10.1002/adhm.201300541.
Chicago
Miller, Philip R., Xiaoyin Xiao, Igal Brener, David Bruce Burckel, Roger Jagdish Narayan, and Ronen Polsky. 2013. “Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+.” Advanced Healthcare Materials 3 (6): 876–881. https://doi.org/10.1002/adhm.201300541.
Harvard
Miller, P. R. et al. (2013) ‘Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+’, Advanced Healthcare Materials, 3(6), pp. 876–881. doi:10.1002/adhm.201300541.
IEEE
P. R. Miller, X. Xiao, I. Brener, D. B. Burckel, R. J. Narayan, and R. Polsky, “Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+,” Advanced Healthcare Materials, vol. 3, no. 6, pp. 876–881, 2013, doi: 10.1002/adhm.201300541.
BibTeX
@article{miller2013microneedle,
title = {{Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+}},
author = {Miller, Philip R. and Xiao, Xiaoyin and Brener, Igal and Burckel, David Bruce and Narayan, Roger Jagdish and Polsky, Ronen},
journal = {Advanced Healthcare Materials},
year = {2013},
volume = {3},
number = {6},
pages = {876--881},
doi = {10.1002/adhm.201300541},
url = {https://doi.org/10.1002/adhm.201300541}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2017 | 9 | |
| 2018 | 9 | |
| 2019 | 22 | |
| 2020 | 18 | |
| 2021 | 17 | |
| 2022 | 20 | |
| 2023 | 16 | |
| 2024 | 19 | |
| 2025 | 21 | |
| 2026 | 5 |
Its field-weighted citation impact is 3.34: it has been cited 3.34 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- microneedle sensors
- potassium ion detection
- ion-selective electrodes
- microfluidics
- point-of-care testing
- porous carbon electrodes
- interference lithography
- electrolyte measurement
Work with this paper
Most-cited papers in Chemistry
- CRC Handbook of Chemistry and PhysicsW.M. Haynes · CRC Press eBooks · 2014 · 58,210 citations
- Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets: procedure and some applications.Harry Towbin, Th. Staehelin, J Gordon · Proceedings of the National Academy of Sciences · 1979 · 53,242 citations
- Crystal structure refinement with SHELXLGeorge M. Sheldrick · Acta Crystallographica Section C Structural Chemistry · 2014 · 45,305 citations
- Comparison of simple potential functions for simulating liquid waterWilliam L. Jorgensen, Jayaraman Chandrasekhar, Jeffry D. Madura and 2 more · The Journal of Chemical Physics · 1983 · 41,735 citations
- Equation of State Calculations by Fast Computing MachinesN. Metropolis, Arianna W. Rosenbluth, M. N. Rosenbluth and 2 more · The Journal of Chemical Physics · 1953 · 38,111 citations
Questions about this paper
How do I cite this paper in APA style?
Miller, P. R., Xiao, X., Brener, I., Burckel, D. B., Narayan, R. J., & Polsky, R. (2013). Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+. Advanced Healthcare Materials, 3(6), 876–881. https://doi.org/10.1002/adhm.201300541
How many times has this paper been cited?
175 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.
Who wrote this paper?
Philip R. Miller, Xiaoyin Xiao, Igal Brener, David Bruce Burckel, Roger Jagdish Narayan, Ronen Polsky.
What is the DOI of this paper?
10.1002/adhm.201300541, permanently at https://doi.org/10.1002/adhm.201300541. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.