Journal article · 2007 · Open access

Microfluidic System for Automated Cell-Based Assays

Philip J. Lee, Navid Ghorashian, Terry A. Gaige, Paul J. Hung

JALA Journal of the Association for Laboratory Automation, 12(6), 363–367 · Published 1 December 2007 · DOI 10.1016/j.jala.2007.07.001

Open PDFView at the publisherCite this paper

In brief

“Microfluidic System for Automated Cell-Based Assays” is a 2007 journal article by Philip J. Lee and 3 co-authors, published in JALA Journal of the Association for Laboratory Automation. OpenAlex counts 69 citations as of 21 November 2026. It is open access: the full text is free to read at JALA Journal of the Association for Laboratory Automation.

Citations
69
Most cited in
2016 (7)
Field-weighted impact
1.69
References
17
Authors
4

Abstract

Microfluidic cell culture is a promising technology for applications in the drug screening industry. Key benefits include improved biological function, higher quality cell-based data, reduced reagent consumption, and lower cost. In this work, we demonstrate how a microfluidic cell culture design was adapted to be compatible with the standard 96-well plate format. Key design features include the elimination of tubing and connectors, the ability to maintain long term continuous perfusion cell culture using a passive gravity driven pump, and direct analysis on the outlet wells of the microfluidic plate. A single microfluidic culture plate contained 8 independent flow units, each with 10(4) cells at a flow rate of 50 μl/day (6 minute residence time). The cytotoxicity of the anti-cancer drug etoposide was measured on HeLa cells cultured in this format, using a commercial lactate dehydrogenase (LDH) plate reader assay. The integration of microfluidic cell culture methods with commercial automation capabilities offers an exciting opportunity for improved cell-based screening.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Lee, P. J., Ghorashian, N., Gaige, T. A., & Hung, P. J. (2007). Microfluidic System for Automated Cell-Based Assays. JALA Journal of the Association for Laboratory Automation, 12(6), 363–367. https://doi.org/10.1016/j.jala.2007.07.001

MLA 9

Lee, Philip J., et al. “Microfluidic System for Automated Cell-Based Assays.” JALA Journal of the Association for Laboratory Automation, vol. 12, no. 6, 2007, pp. 363–367. https://doi.org/10.1016/j.jala.2007.07.001.

Chicago

Lee, Philip J., Navid Ghorashian, Terry A. Gaige, and Paul J. Hung. 2007. “Microfluidic System for Automated Cell-Based Assays.” JALA Journal of the Association for Laboratory Automation 12 (6): 363–367. https://doi.org/10.1016/j.jala.2007.07.001.

Harvard

Lee, P. J. et al. (2007) ‘Microfluidic System for Automated Cell-Based Assays’, JALA Journal of the Association for Laboratory Automation, 12(6), pp. 363–367. doi:10.1016/j.jala.2007.07.001.

IEEE

P. J. Lee, N. Ghorashian, T. A. Gaige, and P. J. Hung, “Microfluidic System for Automated Cell-Based Assays,” JALA Journal of the Association for Laboratory Automation, vol. 12, no. 6, pp. 363–367, 2007, doi: 10.1016/j.jala.2007.07.001.

BibTeX

@article{lee2007microfluidic,
  title     = {{Microfluidic System for Automated Cell-Based Assays}},
  author    = {Lee, Philip J. and Ghorashian, Navid and Gaige, Terry A. and Hung, Paul J.},
  journal   = {JALA Journal of the Association for Laboratory Automation},
  year      = {2007},
  volume    = {12},
  number    = {6},
  pages     = {363--367},
  doi       = {10.1016/j.jala.2007.07.001},
  url       = {https://doi.org/10.1016/j.jala.2007.07.001}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201677
201755
201866
202044
202155
202222
202322
202411
202511
202622

Its field-weighted citation impact is 1.69: it has been cited 1.69 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications

  • microfluidic cell culture
  • HeLa cells
  • lactate dehydrogenase assay
  • drug screening
  • cell-based screening

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Lee, P. J., Ghorashian, N., Gaige, T. A., & Hung, P. J. (2007). Microfluidic System for Automated Cell-Based Assays. JALA Journal of the Association for Laboratory Automation, 12(6), 363–367. https://doi.org/10.1016/j.jala.2007.07.001

How many times has this paper been cited?

69 times, according to OpenAlex on 21 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at JALA Journal of the Association for Laboratory Automation: sign in and open the PDF from this page.

Who wrote this paper?

Philip J. Lee, Navid Ghorashian, Terry A. Gaige, Paul J. Hung.

What is the DOI of this paper?

10.1016/j.jala.2007.07.001, permanently at https://doi.org/10.1016/j.jala.2007.07.001. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 21 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.